To exit the programming menu either wait 10 sec- onds or press the START/STOP key to start firing If the keyboard is locked then press the & keys together & hold down for 5 seconds to unlock ST315B User Handbook Page...
• Program pause/un-pause + segment advance facilities • Keyboard lockable • Delayed start facility - up to 99 hours 59 mins • Power failure recovery • Energy used display • Alarm buzzer & alarm output • Page ST315B User Handbook...
ST315B’s serial number. Next displayed is the thermocouple type to which the ST315B is set. This thermocouple type setting should match the type of thermocouple fitted to the kiln and can be R, S, K or N type.
9 segments can be used per program for complex firing (crystal glaz- ing or glass-making for example). The ST315B ramps the kiln temperature at the required ramp rate until the kiln reaches the soak temperature. It then soaks (dwells) at the soak tem- perature for the soak time.
Page 7
Altering a program When the ST315B is not firing there are no lamps lit on the mimic panel, the run lamp is off and the display shows the kiln temperature with the °C indicator lit. If the left-hand decimal point is on °C...
Page 8
Note: to exit programming without cycling through all of the above steps wait 10 seconds without pressing any keys - the ST315B will revert to the idle display. Alternatively press the START/STOP key to exit programming and to begin firing immediately.
ST315B will apply heating power to the kiln for 12 seconds every 30 seconds. The right-hand decimal point in the display will light for 12 seconds every 30 seconds.
Page 10
Program Record Sheet Segment Ramp Soak Temp Soak Time °C/hr °C hr.min Page ST315B User Handbook...
Page 11
Program No. Notes ST315B User Handbook Page...
Page 12
Operating Notes Kiln too slow If the ST315B is programmed to heat the kiln at a faster rate than the kiln is capable of then the ST315B will turn on full power then wait until the kiln temperature has risen to the correct temperature before proceeding to the next ramp or soak segment.
When the kiln has cooled to less than 40°C the display alternates every 5 seconds between the kiln temperature and To return the ST315B back to idle condition ready for the next firing press the START/STOP key (or turn off the power to the instrument).
Adjusting While Firing Firing values can be adjusted while the ST315B is firing. Also there are program pause/un-pause and segment advance features that are particular- ly useful for glass work. Adjusting Firing Values While firing operate the key to select the required parameter as shown by a flashing lamp on the mimic display.
Page 15
This will advance the segment and will immedi- ately terminate a paused soak - advancing to the next segment (if any). Changes made to the operation of the ST315B in this way are temporary and are not stored.
10°C / 20°C (installer selectable). hr.min Error 6. Maximum firing time exceeded. °C The length of the current firing has °C/hr exceeded an installer selectable (10 - 999 hours) limit. hr.min Page ST315B User Handbook...
Page 17
An alarm buzzer sounds once per second. SWITCH KILN OFF! To reset the ST315B turn off the power to the instrument and have the fault investigated by your installer or kiln service engineer to rectify the fault. Note: these error messages are provided to detect kiln faults and so offer some protection to the kiln.
This is an anti-tamper feature used to ensure that the operation of the ST315B or the program data cannot be altered by un-authorised people. The ST315B can be locked when it is idle (not firing) or while it is firing. It cannot be locked while it is being programmed.
Earthenware High Temperature Glaze is also suitable for Stoneware Low Temperature Glaze. Stoneware Glaze is also suitable for Porcelain. On Glaze Enamel is also suitable for some enamelling work. Heavy Sculpture is also suitable for Terracotta. ST315B User Handbook Page...
Page 20
Supplied by:- www.staffordinstruments.co.uk Page ST315B User Handbook...
Need help?
Do you have a question about the ST315B and is the answer not in the manual?
Questions and answers