Assembly instructions | Grundfos UPM3 Auto 15/70
Alarm codes
In the event of an operating problem then a fault
code will be displayed as below.
Display
Indication
Red LED,
Blocked
Yellow LED
rotor
#5
Red LED,
Too low
Yellow LED
voltage
#4
Red LED,
Electric
Yellow LED
fault
#3
*
Release impeller using screwdriver PH2. Break the
voltage to the pump. Insert the screwdriver into the
center hole of the drive side, press the screwdriver in
about 5 mm, then rotate forward /backward until the
impeller loosens.
Dimensions
45
72
G1
Grundfos UPM3 Auto 15/70 130
Pumpdiagram
EN.33.C.178.2021-11-30
2
Operation
Action
False start
Wait or re-
was 1.33 s.
lease rotor
Only one
Check the
warning, the
voltage to the
pump oper-
pump
ates as normal
Pump stops
Check voltage
because of
to pump / Re-
low voltage or
place pump/
serious fault
impeller*
128
36
92
Weight 1,9 kg
LK Systems AB, Box 66, 161 26 Bromma | www.lksystems.se
Electrical contact
The pump's electrical contact should be connected
to a 230 V 50 hz socket by a qualified electrician in
accordance with the diagram above. This contact
no longer requires a 2-pole switch disconnecter.
The electrical contact should be equipped with a
slow-blow fuse of up to 10 A. The pump should
be disconnected from the mains before any main-
tenance work.