Download Print this page
HANYOUNGNUX HP3 Instruction Manual

HANYOUNGNUX HP3 Instruction Manual

Digital scalemeter

Advertisement

Quick Links

HP3
Digital scalemeter
INSTRUCTION MANUAL
Thank you for purchasing HANYOUNG product.
Please check whether the product is the exactly same as you ordered.
Before using the product, please read this instruction manual carefully.
Please keep this manual where you can view at any time
Safety information
Before using the product, please read the safety information thoroughly and use it properly.
Alerts declared in the manual are classified to Danger, Warning and Caution by their criticality
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury
Danger
Do not touch or contact the input/output terminals because it may cause electric shock.
Warning
•If there is a possibility of an accident caused by errors or malfunctions of this product,
install external protection circuit to prevent the accident.
•This product does not contain an electric switch or fuse, so the user needs to install
a separate electric switch or fuse externally. (Fuse rating : 250 V 0.5 A)
•This product is built in 24 V output. Do not use loaded power more than 70 mA.
•To prevent defection or malfunction of this product, supply proper power voltage in
accordance with the rating.
•When you change the using range (URV, LRV) Please change it before setting up than
any other data. If you change URV or LRV, it could affect other data and cause problem.
•To prevent electric shock or devise malfunction of this product, do not supply the
power until the wiring is completed.
•Since this product is not designed with explosion-protective structure, do not use it
at any place with flammable or explosive gas.
•Do not decompose, modify, revise or repair this product. This may cause malfunction,
electric shock or fire.
•Reassemble this product while the power is off. Otherwise, it may causemalfunction or
electric shock.
•Due to the danger of electric shock, use this product installed onto a panel while an
electric current is applied.
Caution
•The contents of this manual maybe changed without prior notification.
•If the user use the product with methods other than specified by the manufacturer, there
may be bodily injuries or property damages.
•Check to make sure that there is no damage or abnormality of the product during delivery.
•The ambient temperature needs to be 0 ~ 50 ℃ (In case of installment in narrow space,
40 ℃). The ambient humidity is 20 ~ 90 % R.H. (No icing).
•Do not use this product at any place with corrosive (especially noxious gas or ammonia)
or flammable gas.
•Do not use this product at any place with direct vibration or impact.
•Do not use this product at any place with liquid, oil, medical substances, dust, salt or iron
contents. (Use at Pollution level 1 or 2)
•Do not polish this product with substances such as alcohol or benzene.
•Do not use this product at any place with excessive induction trouble, static electricity or
magnetic noise.
•Do not use this product at any place with possible thermal accumulation due to direct
sunlight or heat radiation.
•Install this product at place under 2,000 m in altitude.
•When the product gets wet, the inspection is essential because there is danger of
an electric leakage or fire.
•To avoid inductive noise to input wires, separate the power line from the load wire.
•Keep Input wire away from output wire.
•If there is excessive noise from the power supply, using insulating transformer and noise filter
is recommended. The noise filter must be attached to a panel grounded, and the wire
between the filter output side and power supply terminal must be as short as possible.
•It is effective to use a twisted cable for power supply against noise.
•Turn off the power before changing a sensor.
•This product confirms with IP65. But Waterproof between Panel and product is up to the
packing between them. Please make good use of packing.
•Do not connect anything to the unused terminals.
•After checking polarity of terminal, connect wires at the correct position.
•Mark appropriate on the ON/OFF switch for the emergency.
•For the continuous and safe use of this product, the regular maintenance is recommended.
•Some parts of this product have limited life span, and others are changed by their usage.
•The warranty period for this product including parts is one year if this product is properly used.
Suffix code
Model
Code
HP3-
Digital scalemeter
0
None
Optional
1
RS232
2
RS485
Specification
Power supply
100 - 240 V a.c, 50 - 60 Hz (allowable voltage fluctuation : ±10 %)
voltage
Input contact : 1 Channel
Input specification : 4 - 20 ㎃, 1 - 5 V (Different input contact)
Input
Accuracy : ±0.03 % of F.S
Sampling cycle : 500 ㎳
Input Compensation : -100 ~ 100 % of F.S, Input Filter : 0 ~ 100 s
Output contact : 1C × 2 contacts (AL1, AL2)
Capacity of Contact : 5 A 240 V a.c, (5 A 30 V d.c)
Alarm output
Resolving power : 125 ㎳
Hysteresis : 0 ~ 10 % of F.S
Output contact : 1 contacts
Output range : 4 - 20 ㎃ d.c
Retransmission
Load resistance : 600 Ω max
output
Accuracy : ±0.1 ㎂
Resolving power : 2,600
Insulation
100 ㏁ (500 V .d.c)
resistance
Dielectric strength
2300 V a.c, 50 Hz / 60 Hz for 1 min
Temperature : -5 ~ 50 ℃
Operating ambient
Humidity : 20 ~ 90 % R.H. (With no condensation)
Temperature : -25 ~ 70 ℃
Storage ambient
Humidity : 5 ~ 95 % R.H. (With no condensation)
Dimension and Panel cutout
Parameter structure
POWER ON
Operation
Indicator
Just for
Communication
Option
Only for
485 communication
3
MG0104KE211029
HANYOUNGNUX CO.,LTD
28, Gilpa-ro 71beon-gil,
Michuhol-gu, Incheon, Korea
TEL : +82-32-876-4697
http://www.hanyoungnux.com
Information
[Unit : mm]
+
3 sec
3 sec
OPERATION
SETUP
Parameter
name
Parameter
value
Parameter
name
pa

Advertisement

loading

Summary of Contents for HANYOUNGNUX HP3

  • Page 1 MG0104KE211029 Digital scalemeter HANYOUNGNUX CO.,LTD 28, Gilpa-ro 71beon-gil, INSTRUCTION MANUAL Michuhol-gu, Incheon, Korea TEL : +82-32-876-4697 Thank you for purchasing HANYOUNG product. http://www.hanyoungnux.com Please check whether the product is the exactly same as you ordered. Before using the product, please read this instruction manual carefully.
  • Page 2 Connection diagram Parts Name 4 - 20 mA Transmitter 1 - 5 V d.c. RS232 24 V d.c. Input Input TRX+ TRX- Current Voltage RS485 ALM1 ALM2 POWER ON 3 sec POWER ON 3 sec Operation ① Alarm 1 indicating lamp ⑥ SET : SET mode OPERATION SETUP Indicator...
  • Page 3 •본 기기의 탑재 부품에는 수명이 있는 것과 경년 변화하는 것이 있습니다. •부속품을 포함한 본 기기의 보증기간은 정상적으로 사용한 경우에 1년 입니다. 파라미터 이름 형명구성 형 명 코 드 내 용 485 통신일 경우 표시 HP3- ⃞ 디지털 스케일미터 통신없음 선택사양 RS232 RS485...
  • Page 4 접속도 각부의 명칭 4 - 20 mA Transmitter 1 - 5 V d.c. RS232 24 V d.c. Input Input TRX+ TRX- Current Voltage RS485 POWER ON ALM1 ALM2 3초 POWER ON 3초 운전화면 OPERATION SETUP ① 경보 1 표시램프 ⑥ SET : SET키 ②...