Aeroqual 130 Series User Manual

Aeroqual 130 Series User Manual

Ozone controller

Advertisement

Quick Links

Series 130
Ozone Controller
User Guide
Distributor:
Wessex Power Technology Ltd, Dorset
Tel: +44 (0)845 520 0303 | Fax: +44 (0)845 520 0304
Email: wpt@wessexpower.co.uk | www.wessexpower.co.uk
-
-
Contents
1. Ozone Controller Components
Version 1.1 20.02.10
1.0 Ozone Controller Components
Series 130 Ozone Controller
The following components are supplied with the Series 130 Ozone
Controller:
Series 130 controller assembly inside an FRP enclosure
Ozone sensor head plugged in
User guide
Wall fixing brackets
Eight pole M12 male cable connector
Please check that all these components have been supplied
and
contact
your
dealer
sales@aeroqual.com if any of the components are missing.
1
-
1
2
2
2
3
3
4
4
4
4
6
7
7
8
9
10
11
12
12
13
14
16
or
Aeroqual
on
email
at:
-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 130 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aeroqual 130 Series

  • Page 1: Table Of Contents

    Tel: +44 (0)845 520 0303 | Fax: +44 (0)845 520 0304 • Email: wpt@wessexpower.co.uk | www.wessexpower.co.uk Wall fixing brackets • Eight pole M12 male cable connector Please check that all these components have been supplied contact your dealer Aeroqual email sales@aeroqual.com if any of the components are missing.
  • Page 2: Setting Up The Ozone Controller

    2.0 Setting up the Ozone Controller 2.3 External Control Wiring The M12 ‘8-pole’ connector configuration, viewed from the outside of the 2.1 Monitor Assembly enclosure is as shown below. (Note the centre pole is not used) The Series 130 Ozone Controller comes pre-assembled and ready for use.
  • Page 3: Modes Of Operation

    3.0 Modes of Operation 3.3 Operating as a Controller The Series 130 can operate either as a controller or an alarm switch. Set the mode dip switch (B-2) to position "off". Set the low (“C”) These modes control the two on-board relays in different ways. The and high (“A”) control limits [‘dead band’] by configuring the dip required operating mode is selected via dipswitches as outlined switches as per the dip switch table on page 8.
  • Page 4: Dual Alarm Mode

    3.4 Dual Alarm Mode 3.5 Summary of LED Indicators Set the mode dip switch (B-2) to the dual alarm switch position – "on". Set the low (“C”) and high limits (“A”) by configuring the dip switches as per the dip switch table on page 8. In this mode the low limit dip switch LED Color Meaning controls Relay-1 and the high limit dipswitch controls Relay-2.
  • Page 5: Dip Switch Settings

    3.7 Dip Switch Settings 4.0 Specifications – Series 130 NOTE: If the high set point is set equal to or lower than the low set point, Sensor type Gas Sensitive Semiconductor the LED on the unit will Flash Orange. The exception is when the unit is Measurement range set to dual alarm switch mode and one of the dipswitches is set to zero.
  • Page 6: Dimensions

    6.0 Troubleshooting 5.0 Dimensions Fault description Possible cause Remedy No power Lead connection broken Reconnect power lead Power supply failure Replace 12V power supply Damaged base electronics Replace base Sensor failure when Insufficient warm up Run the sensor for 24-48 hours new sensor Air contaminated Move the sensor to a cleaner...
  • Page 7: Appendix

    Aeroqual Limited is prohibited. “Aeroqual” and “Aeroqual Limited – Making the Invisible Visible” are registered 3. The Aeroqual Series 130 Ozone Controller complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: trademarks of Aeroqual Limited.
  • Page 8: Warranty

    Aeroqual reserves the right to refuse warranty service if this simple steps: information has been removed or changed after the original purchase of the •...
  • Page 9: Guidelines On How To Measure Ozone

    Permanent Controller Placement • The Aeroqual Ozone Controller has been designed to measure the ambient concentration of ozone. The controller must not be placed directly in an ozone stream. •...

Table of Contents