Trust TMSL Series Manual

Wall mounted split

Advertisement

Quick Links

CLASS A
Wall Mounted Split
TMSL Series
TRUST AIR CONDITIONING EQUIPMENT CO.
Prepared By: Engineering & R & D Department.
Shiraz- AUG 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMSL Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Trust TMSL Series

  • Page 1 CLASS A Wall Mounted Split TMSL Series TRUST AIR CONDITIONING EQUIPMENT CO. Prepared By: Engineering & R & D Department. Shiraz- AUG 2015...
  • Page 2: Table Of Contents

    CONTENTS 1. Precaution ..............................1 1.1 Safety Precaution .......................... 1 1.2 Warning ............................1 2. Function ................................ 6 3. Dimension ..............................9 3.1 Indoor Unit ............................. 9 3.2 Outdoor Unit ..........................11 4. Refrigerant Cycle Diagram ........................122 5. Wiring Diagram ............................13 5.1 Indoor Unit ...........................
  • Page 3: Precaution

    1. Precaution 1.1 Safety Precaution  To prevent injury to the user or other people and property damage, the following instructions must be followed.  Incorrect operation due to ignoring instruction will cause harm or damage.  Before service unit, be sure to read this service manual at first. 1.2 Warning ...
  • Page 4 condenser and evaporator.  For installation, always contact the dealer or an Authorized service center. There is risk of fire, electric shock, explosion, or injury.  Do not install the product on a defective installation stand. It may cause injury, accident, or damage to the product. ...
  • Page 5 There is risk of explosion or fire.  If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable. There is risk of electric shock or fire.  Stop operation and close the window in storm or hurricane. If possible, remove the product from the window before the hurricane arrives.
  • Page 6 It can avoid vibration of water leakage.  Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. It may cause a problem for your neighbors.  Use two or more people to lift and transport the product. Avoid personal injury.
  • Page 7 operated. There are sharp and moving parts that could cause personal injury.  Do not drink the water drained from the product. It is not sanitary could cause serious health issues.  Use a firm stool or ladder when cleaning or maintaining the product. Be careful and avoid personal injury.
  • Page 8: Function

    2. Function Model Names Series Capacity Model TMSL-09H410A TMSL-12H410A On-Off TMSL-18H410A TMSL-24H410A TMSC-30H410A...
  • Page 9 Indoor unit Operation by remote controller Anti-freezing control in cooling mode Prevent the water being frozen on evaporator by Golden fin (Optional) checking the evaporator pipe temperature Time Delay Safety control Ionizer (Optional) Indoor fan speed control Turbo wind, high, med, low, breeze.
  • Page 10 Outdoor unit Power relay control Low noise air flow system Hydrophilic aluminum fin The hydrophilic fin can improve the heating efficiency at operation mode. 4 way valve control It is only operated in the heating operation mode except defrosting operation. Anti-rust cabinet Made from electrolytic zinc steel sheet and anti-rust coated components.
  • Page 11: Dimension

    3. Dimension 3.1 Indoor Unit For 9k models, For 12k,18k models...
  • Page 12 For 24k models Model 12k,18k 1445...
  • Page 13: Outdoor Unit

    3.2 Outdoor Unit Model TMSL-09H410A, TMSL-12H410A TMSL-18H410A TMSL-24H410A TMSC-30H410A...
  • Page 14: Refrigerant Cycle Diagram

    4. Refrigerant Cycle Diagram...
  • Page 15: Wiring Diagram

    5. Wiring Diagram 5.1 Indoor Unit TMSL-09H410A...
  • Page 16 TMSL-12H410A TMSL-18H410A TMSL-24H410A...
  • Page 17: Outdoor Unit

    5.2 Outdoor Unit TMSL-09H410A TMSL-12H410A TMSL-18H410A...
  • Page 18 TMSL-24H410A TMSC-30H410A...
  • Page 19: Performance Data

    6. Performance data TMSL-09H410A Cooling Capacity TMSL-09H410A High speed Outdoor conditions (DB) at 0Pa Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 2.78 2.65 2.51 2.40 2.06 2.04 2.01 2.02 21/15ºC DB/WB 0.74 0.77 0.80 0.84 Input 0.60 0.65 0.68 0.70 2.86 2.73 2.59...
  • Page 20 Heating Capacity TMSL-09H410A High speed Outdoor conditions(DB/WB) at 0pa Indoor Conditions (DB) (kW) 24/18ºC 7/6ºC 2/1ºC -5/-6ºC -7/-8ºC 3.51 2.84 2.32 2.11 1.97 15ºC 0.78 0.67 0.58 0.54 0.51 Input 3.40 2.70 2.19 2.05 1.89 20ºC Input 0.85 0.63 0.58 0.55 0.72 3.19...
  • Page 21 TMSL-12H410A Cooling Capacity TMSL-12H410A High speed Outdoor conditions (DB) at 0Pa Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 3.50 3.33 3.16 3.03 2.59 2.57 2.53 2.54 21/15ºC DB/WB 0.74 0.77 0.80 0.84 Input 0.76 0.83 0.86 0.89 3.60 3.43 3.26 3.06 2.70 2.68...
  • Page 22 3.32 3.16 3.00 2.82 2.29 2.27 2.25 2.20 24/17ºC DB/WB 0.69 0.72 0.75 0.78 0.75 0.80 0.84 0.88 Input 3.38 3.22 3.13 2.91 2.30 2.29 2.27 2.21 27/19ºC DB/WB 0.68 0.71 0.73 0.76 0.77 0.81 0.90 0.86 Input 3.44 3.35 3.25 3.00 2.72...
  • Page 23 TMSL-18H410A Cooling Capacity TMSL-18H410A High speed Outdoor conditions (DB) at 0Pa Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 5.25 5.00 4.74 4.54 3.89 3.85 3.79 3.81 21/15ºC DB/WB 0.74 0.77 0.80 0.84 Input 1.33 1.44 1.50 1.55 5.41 5.15 4.90 4.59 4.05 4.02...
  • Page 24 4.97 4.74 4.50 4.22 3.43 3.41 3.38 3.29 24/17ºC DB/WB 0.69 0.72 0.75 0.78 1.31 1.40 1.46 1.53 Input 5.07 4.83 4.69 4.36 3.45 3.43 3.40 3.32 27/19ºC DB/WB 0.68 0.71 0.73 0.76 1.34 1.41 1.56 1.49 Input 5.16 5.02 4.88 4.50 4.08...
  • Page 25 TMSL-24H410A Cooling Capacity TMSL-24H410A High speed Outdoor conditions (DB) at 0Pa Indoor Conditions (kW) 21ºC 28ºC 35ºC 43ºC 7.21 6.86 6.51 6.23 5.34 5.28 5.21 5.23 21/15ºC DB/WB 0.74 0.77 0.80 0.84 Input 1.83 1.98 2.07 2.13 7.42 7.07 6.72 6.30 5.57 5.51...
  • Page 26 6.83 6.50 6.18 5.80 4.71 4.68 4.64 4.52 24/17ºC DB/WB 0.69 0.72 0.75 0.78 1.80 1.92 2.01 2.11 Input 6.96 6.63 6.44 5.99 4.73 4.71 4.67 4.55 27/19ºC DB/WB 0.68 0.71 0.73 0.76 1.84 1.94 2.15 2.05 Input 7.08 6.89 6.70 6.18 5.60...
  • Page 27 Air Conditioning Systems Cooling & Heating TRUST AIR-CONDITIONING EQUIPMENT CO. Shiraz office: 8 th floor, Alvand Blog., Dostan St., Moaliabad Ave., SHIRAZ, IRAN., Post code: 71877-14446 Tel.: +98-71-36341070 Fax.: +98-71-36341094 Tehran office: No. 19- koohe nour St.- Motahhari St.- TEHRAN, IRAN., Post code: 15876-73111 Tel.: +98-21-89389...

Table of Contents