HYGIENE MONITOR SYSTEM
Clean-Q
User Manual
TELTRON INC.
TEL : +82-42-360-2012 FAX : +82-42-360-2010 E-mail : teltron@teltron.com

Advertisement

Table of Contents
loading

Summary of Contents for TELTRON Clean-Q

  • Page 1 HYGIENE MONITOR SYSTEM Clean-Q User Manual TELTRON INC. TEL : +82-42-360-2012 FAX : +82-42-360-2010 E-mail : teltron@teltron.com...
  • Page 2 Before using 1. As Clean-Q’s measured value shows the indirect contamination level, exact degree and type should be confirmed by professional organizations. 2. Guideline of contamination level of each item is only for reference. 3. Disposable Q-tube is required in order to use Clean-Q. Please inquire purchase department.
  • Page 3: Table Of Contents

    4.4 Lighting Setup 4.5 Sound Setup 4.6 Auto-Shutoff Setup 5. Error Message while Clean-Q runs ………………………………………… 11 6. How To Use PC Program of Clean-Q ……………………………………… 12 6.1 Display after selecting ‘5. PC connection’ 6.2 Program installation and connection 6.3 Program execution 6.4 Communication port connection...
  • Page 4: What Is Clean-Q

    1. What is Clean-Q? Clean-Q is portable ATP measuring device. ATP is acronym of Adenosine Tri-Phosphate, and every living organism(animal, plant, microorgan- ism, yeast, etc.) has ATP and uses ATP as energy source for life activities. ATP can be an indicator for the existence of living organism.
  • Page 5: Structure Of Clean-Q

    2. Structure of Clean-Q. 2.1 Components in box • Clean-Q components in box • Clean-Q terminal 1ea • Terminal pouch 1ea • PC program CD 1ea • USB cable 1ea • AA alkaline battery 2ea • User’s manual 1ea...
  • Page 6: Clean-Q Button Description

    3. How To Use Clean-Q 3.1 Power On • Once power button is pressed about 2 seconds, Clean-Q is on and 5 seconds are required for system checking , during which Q-tube should not be in Clean-Q and the cover should be closed.
  • Page 7: Preparation

    • ‘Retry’ : Check the system againConfirm whether the cover may open or be cracked or not. If the problem occurs continuously, please call to TELTRON sercenter. • ‘Ignore’ : Ignore and go to next stepTELTRON does not guarantee the performances of Clean-Q in case of choosing ‘Ignore’...
  • Page 8: Measurement

    <Measured target change> • User name and measured target name can be changed after installing PC-Sync program in enclosed CD on PC. ( Refer ‘6. Clean-Q PC program usage) • Use no measured target mode if you do not need.
  • Page 9 • Press so that the solution at the upper part can run down well. • Shake Q-tube during 10 seconds so as reagent to react well with measured • ‘Start’ message appears after 10 seconds • If ‘Start’ message appears, insert Q-tube in the terminal...
  • Page 10: Measurement Completion

    • [150~200]’ : This is guideline value of ‘safety,’ ‘caution,’ or ‘contamination’. It is recommended value and not absolute one. • ’Safety’: It means measured target is safe on the basis of the guideline provided by TELTRON. • ‘0’ : No ATP was detected from measured target.
  • Page 11: Time Setup

    4.2 Time Setup • Setting up terminal time. • Once setup is made at the beginning, it is not reset even after removing AA batteries due to internal battery. : Increase time : Move Next : Move Previous : Exit without Saving 4.3 PC Connection •...
  • Page 12: Sound Setup

    Please be cautious of this. 5. Error Message while Clean-Q runs When measurement begins, if upper cover is open, the following error message appears.
  • Page 13: How To Use Pc Program Of Clean-Q

    • If OK button is pressed after selecting ‘5. PC Connection,’ the following figure is displayed 6.2 Program install and PC connection • Inset enclosed CD into PC and Install the program by double click ‘CDM20814_Setup’ • Copy Clean-Q_Sync_Manager_ENG’and paste it to desktop. • Connect between Clean-Q and PC with USB cable.
  • Page 14: Program Execution

    6.3 Program execution • Following window is displayed after executing Clean-Q_Sync_Manager. 6.4 Communication port connection • Check communication port number in order to connect terminal to PC. • Follow below figures step by step. 1) ‘Start’ => ‘Control Panel’.
  • Page 15 2) Double click ‘System’ 3) Click ‘Hardware’ and ‘Device Manager’. 4) Check COM port number of USB Serial Port.
  • Page 16 5) After executing SyncManager, select proper port number and click ‘connect’ button on lower part of window. 6.5 Data importing • Click ‘Import from Clean-Q’ button in order to import user information, guideline, and measured result. <Data importing completed> 6.6 Save measured data to excel file.
  • Page 17 • Delete saved measured records in order to add user information. • Click ‘Delete all’ and ‘Reset’ • Type in ‘ID’ and ‘Name’, and Click ‘Add’. • Click ‘Save to Clean-Q’ after adding user information is completed.
  • Page 18 (2) Delete user information • Check box of useless user information, and click ‘Delete. • When selecting every user information, use ‘Select all’. (3) Add and delete of guideline information • The way to add or delete guideline information is the same as that of user information. ※...
  • Page 19 □ Repairs 1. Free repairs 1) Performance or function failure occurred with normal usage within the warranty period 2) The same failure occurred within 2 months after fixed by TELTRON’s service center engineer. 2. Paid Repairs 1) Expired warranty period...
  • Page 20 TELTRON INC. #305-343 ITplex 202, 26-41 Gajeongbuk-Ro, Yuseong-Gu, Daejeon, Korea TEL : +82-42-360-2012 FAX : +82-42-360-2010 E-mail : teltron@teltron.com / URL : www.teltron.com...