Controller
IF-4041 Gateway
00-4041-02002x

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Interflex IF-4041 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Allegion Interflex IF-4041

  • Page 1 Controller IF-4041 Gateway 00-4041-02002x...
  • Page 2: Table Of Contents

    1 General information.......................... 1.1 Short description ......................... 1.2 Scope of delivery ........................1.3 Intended use ..........................1.4 Target group ..........................1.5 Safety ............................1.6 Abbreviations ..........................2 System overview..........................2.1 Range of functions ........................2.2 Electronic assembly units ......................3 Mounting the Gateway........................4 Connecting the Gateway ........................
  • Page 3 Tool for checking the certificate chain ..................21 6.7 Configuring PKI and TLS ......................22 Configuration ..........................22 7 Technical specifications ........................8 Open Source Program Packages ....................9 Disposal ............................. 10 Declarations of Conformity......................10.1 EU Declaration of Conformity ..................... 25 10.2 UKCA Declaration of Conformity ....................
  • Page 4: General Information

    General information 1 General information 1.1 Short description The IF-4041 Gateway offers maximum security for the seamless connection of Opendor wireless locking components to the IF-6040 access control system. With over-the-air technology, every door becomes an online door. The Gateway is an ideal solution for cost- effective, uncomplicated and wireless compliance with current security standards for a wide range of applications.
  • Page 5: Safety

    General information 1.5 Safety WARNING Danger to life due to electric shock People can be seriously hurt or killed through physical contact with live parts (e.g. 230 V~). Make sure that you cannot touch live lines during installation. Switch off the power supply of the devices. Please observe the applicable safety regulations and take all precautionary measures to ensure safe installation.
  • Page 6: System Overview

    System overview Ground IEEE Institute of Electrical and Electronics Engineers NC contact Normally closed contact NO contact Normally open contact Power over Ethernet RFID Radio-Frequency Identification Shield Secure shell 2 System overview 2.1 Range of functions Main functions of the IF-4041 Gateway: Certificate-based encryption from the terminal via the Gateway to the host Grant or withdraw access permissions online in real time No cabling to end device required...
  • Page 7: Electronic Assembly Units

    Mounting the Gateway 2.2 Electronic assembly units Connection for serial service DIP switches Reset button cable USB connection for dongle Power supply without PoE RJ45, Ethernet 10/100 of IF-ServiceApp 3 Mounting the Gateway 1. Open the lid of the housing. 2.
  • Page 8: Initial Operation

    Initial operation 5 Initial operation The IF-4041 Gateway is part of the Controller product family. That is why the term Controller is used in this section and in the following sections. Prerequisites ü Service IF6040 Pki Service installed ü IF6040 Tls Proxy service installed ü...
  • Page 9: Service Interface

    Initial operation Service interface Accessing the controller via SSH requires the freeware PuTTY version 0.73 or higher: 1. Switching on the power supply 2. Establish serial connection between host computer and controller 3. Open PuTTY 4. Check and adjust parameters 5.
  • Page 10: Configuring The Controller In If-6040

    Initial operation 5.2 Configuring the controller in IF-6040 In IF-6040 under  Access > Access management > Controllers: 1. Select Interflex CHP under Options in the Transmission protocol field 2. Enter the serial number of the controller under Connections. 3. Select a suitable Configuration under Connections >...
  • Page 11: Service Interface

    Initial operation Service interface 1. In IF-6040 under Access > Access management > Controllers: Select Perform action > Register controller 2. Copy the URL of the IF-6040 in the registration window 3. In the console: Enroll -u <URL of IF-6040> 4. Copy password in the registration window 5.
  • Page 12: Further Information For Initial Operation

    Further information for initial operation 6 Further information for initial operation 6.1 Restarting the controller Some changes require a restart of the controller. You can do this directly on the controller or with the appropriate commands via the console. Warm boot A warm boot performs the following actions: Close application Restart application...
  • Page 13 Further information for initial operation Cold boot All settings made on the controller via IF-6040 or OC Task are deleted or reset to default. System or operating system settings, such as the IP address or password, are retained. Use the cold boot during initial operation and in the event of malfunctions that cannot be remedied by other means, e.g., a warm boot.
  • Page 14: Users And Passwords

    Further information for initial operation 4. Reset switch position: Associated console command: factory-reset full 6.2 Users and passwords The default user is fieldservice. A dialog is presented after the first login to specify the password for this user. Login to the controller and specify the password Prerequisites for a valid password Minimum 8 characters in length Contains upper and lowercase letters and numbers...
  • Page 15: Script Showlog

    Further information for initial operation The maximum size of the log files is 5 MB. If the file size is reached: The current log file is renamed: <service-name>-<controller-hostname>.<Number of backup>.log New log file with the original name is created. This log file is written to. The higher the number in the backup’s file name, the older the backup.
  • Page 16: Checking And Setting Network Parameters

    Further information for initial operation Command Result Shows the last 10 lines of the current log file of the cloudreadyd service showlog -f and from there every additional line Shows the last 10 lines of the current log file of the service-app-mgr showlog -s -f service and from there every additional line View the log file...
  • Page 17: Restoring The Default Ip Address

    Further information for initial operation Restoring the default IP address You have the option of restoring the default IP address if you can no longer reach the controller after changing the IP address. Perform a factory reset. Further information can be found in the section Restarting the controller. Static IP address 1.
  • Page 18: Dynamic Ip Address

    Further information for initial operation Dynamic IP address 1. List connections with nmcli-wrapper -l 2. Select the connection 3. Open the connection with nmcli-wrapper -e for editing Current Connection Type: [Wired-connection] Current Method: [DHCP] 1: Static-IP 2: DHCP Select a value from 1 to 2 [2]: 2 4.
  • Page 19: Ifcertificationtool.exe

    Further information for initial operation IFCertificationTool.exe Menu or keyboard commands File > Page for creating a new, derived customer system certificate New custom system certificate File > New Tls certificate Page for saving a file (certificate chain) with the customer system certificate (TLS) as the last certificate that cannot be derived further File >...
  • Page 20: Iftlscertificationtool.exe

    Further information for initial operation Page for deriving and saving a new customer system certificate (TLS) The saved file contains the three derived certificates with the customer system certificate (TLS) as the last certificate that cannot be derived further. Custom certificate key Supplied customer certificate and transport password (transport key) Custom certificate Path to the supplied customer certificate...
  • Page 21: Tool For Checking The Certificate Chain

    Further information for initial operation Page for importing the customer system certificate (TLS) Field Tls certificate key Password for the derived customer system certificate (TLS) Field Tls certificate Storage location of the file (certificate chain) with the derived customer system certificate (TLS) Import certificates button To import certificates Tool for checking the certificate chain...
  • Page 22: Configuring Pki And Tls

    Further information for initial operation 2. Check certificate chain (six certificates): 6.7 Configuring PKI and TLS The files for both IF6040 Pki Service and IF6040 Tls Proxy services are located in the IF6040\CommunicationSecurity\... subfolder of the installation path. C:\Program Files\Interflex\IF6040\CommunicationSecurity\... (even if you chose the suggested 32-bit path during installation).
  • Page 23 Further information for initial operation Connection data After installation, the file only contains default entries. The settings for HostName and HostPort, for example, are based on the assumption that all three relevant services are installed on the same computer. You therefore have to edit the entries: 1.
  • Page 24: Technical Specifications

    Technical specifications 7 Technical specifications Power supply Mains voltage 18 – 24 V AC/DC Power supply via Ethernet PoE IEE 802.3at of power class 3 (up to 12.95 W) Power consumption Approx. 5 VA Equipment Installation type Indoor Interfaces Ethernet, BLE to Gateway Service interfaces Ethernet network connection with SSH RS232 with 115200 baud, 8 bits, no parity, 1 stop...