OPERATION & SERVICE MANUAL Model: 20-4500-7000 Oxygen Booster 03/2009 Rev. 10 Tronair, Inc. Phone: (419) 866-6301 | 800-426-6301 1 Air Cargo Pkwy East Web: www.tronair.com Swanton, OH 43558 Email: sales@tronair.com...
Page 2
REVISION DATE TEXT AFFECTED 08/2005 Modified Parts List 10/2005 Modified 3.3 Assembly 03/2008 Added CE marling and Declaration of Conformity 07/2008 Major revision 02/2009 Major revision 03/2009 Major revision...
Model: 20-4500-7000 Oxygen Booster This product cannot be modified without the written approval of Tronair, Inc. Any modifications done without written approval voids all warranties and releases Tronair, Inc., it suppliers, distributors, employees, or financial institutions from any liability from consequences that may occur. Only Tronair OEM replacement parts shall be used.
Training: Read this entire manual prior to operation of the unit. All personnel using this oxygen cart should understand and follow this manual and receive training. We encourage our customers to call Tronair to discuss any operating or testing requirements.
Model: 20-4500-7000 Oxygen Booster PREPARATION FOR USE/ASSEMBLY INSTRUCTIONS UNPACKING The oxygen cart’s manifold system and oxygen booster have been thoroughly cleaned and inspected prior to packaging and shipment. After opening the shipping container and removing the unit, inspect it thoroughly for shipping damage.
Model: 20-4500-7000 Oxygen Booster OPERATION FILL PROCEDURE Connect shop air supply Close high pressure oxygen gas output valve Reduce output pressure regulator to minimum pressure (counter clockwise) Remove cap from output hose and immediately loosely connect hose to aircraft component SLOWLY open shut off valve on the oxygen bottle Adjust output pressure regulator for 50 –...
Section 3 - Safety of this manual prior to performing any maintenance on the unit. The inlet shop air filter should be inspected every 300 - 600 hours of service or every two years, whichever comes first. The replacement air filter element is available from Tronair, part number PC-1145. OXYGEN COMPONENTS:...
GUARANTEES/LIMITATION OF LIABILITY Tronair products are warranted to be free of manufacturing or material defects for a period of one year after shipment to the original customer. This is solely limited to the repair or replacement of defective components. This warranty does not cover the...
Page 11
Model: 20-4500-7000 Oxygen Booster Parts List When ordering replacement parts/kits, please specify model, serial number and color of your unit. Item Part Number Description HC-2278 Gauge, Pressure (0-160 psi) TF-1047-01*18.0 Hose, Push-On TF-1047-05*09.7 Hose, Push-On N-2055-03-S Reducer, Tube N-2017-14-S Tee, Male Run...
Page 12
When ordering replacement parts/kits, please specify model, serial number and color of your unit. Parts on this page are oxygen cleaned per SAE spec AIR 1776 as an assembly, therefore individual parts will not be sold. Contact your Tronair representative regarding repair. 03/2009 | Rev. 10...
Page 13
APPENDIX I Maxpro Operation & Service Manual with Safety Precautions...
Page 25
DECLARATION of CONFORMITY The design, development and manufacture is in accordance with European Community guidelines 20-4500-7000 Relevant provisions complied with by the machinery: 2006/42/EC Relevant standards complied with by the machinery: EN ISO 12100-1 CGA G-4.1 - 2004 SAE ARP 1176...