E N G L I S H ASPIRCOMFORT PRO X 460H GENERAL 1.1 INTRODUCTION This manual was prepared with the aim of making the installation and management of your system as simple as possible. By reading and applying the suggestions of this manual, you can achieve the best performance of the purchased product.
Page 3
E N G L I S H ASPIRCOMFORT PRO X 460H • It is forbidden to insert objects and substances through the air intake and supply grids. • It is forbidden to open the access doors to the inside of the device, without firstly placing the system’s main switch on ‘off’.
Page 4
E N G L I S H ASPIRCOMFORT PRO X 460H 1.4 WARNINGS The unit must be installed by qualified and authorised personnel according to the rules in force in the various countries. If installation is not carried out, this could lead to a situation of danger. Avoid installing the unit in very damp rooms or where there are large sources of heat.
E N G L I S H ASPIRCOMFORT PRO X 460H 1.5 CONFORMITY The CE marking (applied on each machine) certifies compliance with the following Community standards: • Low Voltage Directive 2014/35/EC • Electromagnetic Compatibility Directive 2014/30/EC • RoHS2 2011/65/UE •...
Page 6
E N G L I S H ASPIRCOMFORT PRO X 460H ALL IN ONE Complete unit capable of exchanging air and integrating the cooling thermal demands of the served rooms. The unit is complete with all components for its operation and ready to use. UVC LAMP (AP20384 ACCESSORY) AND VOC SENSOR The unit is equipped with a UVC lamp (AP20384 accessory), which enables a germicidal action to be carried out on the air introduced from outside through the effect of UVC;...
E N G L I S H ASPIRCOMFORT PRO X 460H 1.9 MAIN COMPONENTS OF THE UNIT Compressor Intake fan Exhaust fan Input coil Exhaust coil Electrical panel Display Outdoor air prefilter Epm1 filters UVC lamp (AP20384 accessory)
E N G L I S H ASPIRCOMFORT PRO X 460H 1.10 PACKAGING AND TRANSPORT The units are prepared for transport secured to a wooden pallet and placed inside cardboard boxes. To facilitate relocation, the units have a wooden pallet and hooks on the base so it can be lifted and positioned in the place of installation.
E N G L I S H ASPIRCOMFORT PRO X 460H INSTALLATION 2.1 INSTALLATION CONDITIONS The unit must be installed based on national and local regulations governing the use of electrical devices and based on the following indications: • install the unit inside residential buildings with room temperature between 0°C and 45°C; •...
E N G L I S H ASPIRCOMFORT PRO X 460H 2.2 UNIT POSITIONING CEILING INSTALLATION To mount the unit on the ceiling, it is necessary to: • Remove the front grille by prying it upwards and pulling it out towards the bottom first; •...
E N G L I S H ASPIRCOMFORT PRO X 460H 2.3 CONDENSATE DISCHARGE CONNECTION Due to the thermodynamic heat recovery system of the dehumidification coils, the humidity contained in the indoor air condenses inside the unit. For the correct operation of the heat recovery unit, it is therefore necessary to connect the condensate discharge to the hydraulic system (drain);...
E N G L I S H ASPIRCOMFORT PRO X 460H AERAULIC CONNECTIONS 3.1 AERAULIC ORIENTATIONS The unit has 4 male circular rear fittings of different Ø and one rectangular front opening based on the size; To correctly connect the air ducts, refer to the following diagram and stickers on the unit. Table of unit aeraulic connection diameters Codes AP20068...
Page 13
E N G L I S H ASPIRCOMFORT PRO X 460H 3.2 INSTALLATION OF EXTERNAL GRILLES Cut off any excess part of the tube using a standard cutter. To position the external grilles, proceed as follows: - attach the chains to the end of the springs; - fold the external dampers back on themselves;...
E N G L I S H ASPIRCOMFORT PRO X 460H ELECTRICAL CONNECTIONS 4.1 GENERAL - Before starting any operation to perform the electrical connection make sure that the unit is not electrically powered. - Perform the necessary electrical connections referring exclusively to the wiring diagram attached to this manual.
Page 15
E N G L I S H ASPIRCOMFORT PRO X 460H 4.2 POSITIONING AND PROCEDURES OF THE CONNECTIONS The unit is supplied with all electrical connections prepared and with a schuko plug for connection to the mains; The electrical cable entry is located at the rear of the unit where two dn 16mm passages are provided; If it is not possible to carry the wiring from the rear of the unit, it is possible to exit to the right side of the unit using the pre-cut hole on the side;...
Page 16
E N G L I S H ASPIRCOMFORT PRO X 460H 4.3 INSERTION OF REMOTE CONTROL BATTERIES Only a CR2025 3 V dry lithium battery (included in the scope of supply) may be used for the remote control. Spent batteries may only be disposed of at collection points set up by Local Authorities for this type of waste. To insert the battery, open the snap-on battery door at the bottom of the remote control.
E N G L I S H ASPIRCOMFORT PRO X 460H 4.4 WIRING DIAGRAM 4.5 CONNECTIONS N-L-PE – POWER SUPPLY The unit is supplied with a power supply socket connected to terminals N , L , PE ; HT- EXTERNAL HEATER It provides for the connection of the additional electrical resistance (Accessory) to be inserted on the air supply duct CP- ON OFF REMOTE...
Page 18
E N G L I S H ASPIRCOMFORT PRO X 460H COMMISSIONING AND METHOD OF USE 5.1 OPERATION OF ON-BOARD WIFI CONTROL PANEL AND REMOTE CONTROL The unit is controlled either via the on-board wifi panel or via the supplied infrared remote control. You can also download the app and control the main functions from IOS or ANDROID systems;...
E N G L I S H ASPIRCOMFORT PRO X 460H SWITCHING THE UNIT ON AND OFF In order to operate the appliance using the remote control or the touch screen display, it is necessary to either switch on the main switch which has been provided on the power supply line (the technician who installed the appliance will be able to be more precise about its position), or insert the appliance's power plug into the system's socket.
E N G L I S H ASPIRCOMFORT PRO X 460H VENTILATION-ONLY FUNCTION When this function is activated, the compressor is never switched on and the appliance has no effect on either the temperature or the humidity of the air in the room. It is possible to select Ventilation only the fan speed.
E N G L I S H ASPIRCOMFORT PRO X 460H TIMER FUNCTION The logic of the device provides the user with the possibility of programming its activation or deactivation, as desired. While the air conditioner is switched on, it is possible to program it to switch off by pressing the Timer button, followed by setting the number of hours (from 1 to 24) after which the appliance will be placed in stand-by mode.
E N G L I S H ASPIRCOMFORT PRO X 460H MAINTENANCE To always guarantee correct and optimal unit operation, it is necessary to periodically perform all of the maintenance activities. 6.1 EPM1 FILTER CLEANING OR REPLACEMENT To replace the filters, or periodically clean them, do the following: •...
E N G L I S H ASPIRCOMFORT PRO X 460H 6.2 PRE-FILTER REPLACEMENT To clean the outside air prefilter, proceed as follows: • cut off the power to the unit; • Remove the front grille; • Remove the bottom panel through the front screws and out of the rear seats; •...
Page 24
E N G L I S H ASPIRCOMFORT PRO X 460H 6.3 UVC LAMP MAINTENANCE (AP20384) To service the UVC lamp (AP20384 accessory): • Cut off the power supply to the unit; • Remove the front grille; • Remove the intake air filter to access the UVC lamp; •...
Page 25
E N G L I S H ASPIRCOMFORT PRO X 460H ALARMS In case of any problems or failures, take note of any error code appearing on the remote control screen, take note of the model and the serial number of the unit you possess (data provided on the identification plate attached on the side of the unit) and contact the installer.
Page 26
E N G L I S H ASPIRCOMFORT PRO X 460H High Vibrating panels Check the integrity of the unit panels vibrations and profiles. Check the correct closing of the unit cover and the panel that covers the electronic board. Make sure there are no walls that can transmit vibrations to the wall / floor / false ceilings.
E N G L I S H ASPIRCOMFORT PRO X 460H 7.2 TABLE OF ALARMS REPORTED ON THE DISPLAY ALARM CAUSE OPERATION Room temperature probe RT faulty The Cooling, Dehumidification and Heating functions can be activated regularly. The control only monitors the internal battery antifreeze.