  • Page 1 PLC Data concentrator DC12U G3 PLC User Manual Version 1.3 “ELGAMA – ELEKTRONIKA” Ltd., Lithuania 2020 DC12U G3 v1.3...
  • Page 2 DC12 PLC Data Concentrator User Manual This Page is blank intentionally. Please consider the environment before printing this document.
  • Page 3 EVEN IF ELGAMA-ELEKTRONIKA IS INFORMED OF THE POSSIBILITY OF SUCH DAMAGES. FURTHERMORE, ELGAMA-ELEKTRONIKA WILL NOT BE LIABLE FOR THIRD PARTY CLAIMS AGAINST CUSTOMER FOR LOSSES OR DAMAGES. ELGAMA-ELEKTRONIKA IN NO EVENT WILL BE LIABLE FOR ANY DAMAGES IN EXCESS OF THE AMOUNT ELGAMA-ELEKTRONIKA RECEIVED FROM THE END-USER FOR THE PRODUCT.
  • Page 4: Table Of Contents

    Supported Browsers..........................12 WEB UI user levels ..........................12 WEB UI supported functions ....................... 12 Usage ............................12 4.1.1 Access DC12U WEB UI ......................12 DCU running status information ....................13 4.2.1 Basic Information........................ 13 4.2.2 DC12U collected data monitoring ..................14 4.2.3...
  • Page 5 SMS Commands from phone...................... 47 6.2.1 SMS command examples ....................48 Appendix A. Data gathered by DC12U from meters ................... 49 Appendix B. GSM LED description ......................50 Appendix C. DC12U Dimensions and installation..................51 Please consider the environment before printing this document.
  • Page 6: Introduction

    1 Introduction This manual’s feature descriptions are based on the software release 1.2. The features listed here are the subset of features that are supported by the DC12U PLC data concentrator. 1.1 Audience This reference manual is intended for administrators and other engineers responsible for installing and managing the DCU by using the DC configurator or Web User Interface (Web UI).
  • Page 7: Notes, Notices And Cautions

    DC12 PLC Data Concentrator User Manual 1.4 Notes, Notices and Cautions Below are examples of the three types of indicators used in this manual. When administering your DCU using the information in this document, you should pay special attention to these indicators. Each example below provides an explanatory remark regarding each type of indicator.
  • Page 8: Safety

    DC12 PLC Data Concentrator User Manual 2 Safety 2.1 Safety requirements Installing, uninstalling, parameterization and verification can be performed only by authorized organizations that have qualified technicians. Only qualified persons should install DCU. DCU connection or disconnection from network should be done when voltage in the network is turned off.
  • Page 9: Proper Disposal Of Product

    DC12 PLC Data Concentrator User Manual Procedure of returning DCU to manufacturer. In case malfunctions cannot be eliminated on the spot, the DCU should be returned to the manufacturer for repair or replacement. DCU upon return to manufacturer must have Passport with notices of organization in charge of their exploitation and short description of DCU malfunctioning.
  • Page 10: Technical Specifications

    < 3 Dimensions (HxWxD), mm 290 x 180 x 95 Average service life (years) DC12U has 512 MB RAM and 4096 MB Flash. DC12U is designed to support up to 500 meters. Please consider the environment before printing this document.
  • Page 11: Concentrator And Modem Status Indication

    91kHz) frequency bands. Electromagnetic emissions of the modem does not exceed standardized values according EN55022 when operating at above two frequency bands. DC12U PLC modem ensures PLC MAC security according G3 PLC technology by using 128 bit length pre- shared key (PSK). DC12U will be configured with purchaser provided PSK.
  • Page 12 DC12 PLC Data Concentrator User Manual GSM module indicators (see Appendix B. GSM LED description for details): • LED1 [Power] – RED. Connected directly to power supply • LED2 [Network] – RGB GSM network connection LED. • LED3 [Activity] – RG GSM network activity LED. Please consider the environment before printing this document.
  • Page 13: Dcu Configuration Using Web Ui

    4 DCU Configuration using Web UI Supported Browsers DC12U WEB UI supports following browsers: Firefox, Microsoft Edge and Google Chrome. DCU comes with self-signed HTTPS certificate. You will receive warning from your browser about untrusted certificate until you upload your HTTPS certificate to DCU.
  • Page 14: Dcu Running Status Information

    DC12 PLC Data Concentrator User Manual Port ETH0 Port ETH1 Figure 4.1 Ethernet port locations on Ethernet module 4.2 DCU running status information 4.2.1 Basic Information. WEB UI is divided into two main parts. Language selector and main menu tree is displayed on the left side.
  • Page 15: Dc12U Collected Data Monitoring

    Alerts – Current active DCU alerts. Clicking on Alerts icon expands active alerts list. • Connected users – list of currently connected to DC12U users. Access level and user IP address. • Latest log entries – list of latest important log entries.
  • Page 16 DC12 PLC Data Concentrator User Manual First submenu – List. Contains list of meters currently present in DC12U database. DCU itself is also present in this list. No electricity meter is present in the current DC12U modification. Amount of listed meters per page can be changed to 7, 10, 20, 25 rows. User can search meter list using any part of meter serial number.
  • Page 17: Meters - Generate Csv

    It is possible to generate billing profile report for selected dates. CSV report includes all meters available in specific DC12U. Data concentrator stores generated reports for repeated downloads. Maximum number of stored reports – 15. When limit is reached, oldest stored report will be deleted from DC12U. Administrator can manually delete reports one by one.
  • Page 18 DC12 PLC Data Concentrator User Manual Figure 4.6. Meters tree. Hierarchical layout When hovering over each meter, detailed information related to PLC connection, is displayed. Figure 4.7. Detailed PLC connection information for selected meter Detailed description of PLC connection information: •...
  • Page 19: Status. System

    PLC PAN ID – current PAN ID used by DCU. Alarm also is displayed by alarm LED on DC12U faceplate. If hardware platform is equipped with buzzer, it will sound when alarm is triggered. Alarm can be triggered by following events: •...
  • Page 20 “Status” page or by pressing and holding Enter (first from the right) key on keypad for 5 seconds. Figure 4.9. Electrical status Electrical. Phases currently present on DC12U feed. Data is refreshed every 5 seconds. Figure 4.10. Ethernet ports status Ethernet. Information about Ethernet ports.
  • Page 21 DC12 PLC Data Concentrator User Manual Figure 4.11. GSM status information GSM. Status of GSM modem IP interface. If modem is connected to network, status will be displayed green. IP address, subnet mask and default gateway, received from cellular operator, will be displayed accordingly.
  • Page 22: Meters Activity

    • RAM Size – total available RAM in kilobytes. • RAM Status – current RAM usage status (refreshes every 5 seconds). DC12U will auto reboot if less than 50MB of free RAM is available. Figure 4.13. Operating statistics RAM Free, CPU usage, Disk usage, Network usage. Graphs representing current usage of respective components.
  • Page 23: Status. Runtime Information

    There may be some graphical issues displaying table if very long period is selected. 4.2.7 Status. Runtime information. Runtime information page displays detailed statistics of DC12U operating system status. Usually information needed only for debugging purposes. All data is read only.
  • Page 24 Figure 4.15. System settings > Main page • Alarm status can be triggered manually. On the right column actual setting from DC12U is displayed. It is refreshed every 5 seconds. When triggered, LED on DCU will flash (Buzzer will beep if it is installed) •...
  • Page 25 DC12 PLC Data Concentrator User Manual Figure 4.17. NTP settings page GSM configuration tab allows setting up GSM modem parameters. • GSM Mode – Select GSM mode: o Only 2G. Modem communicates only in 2G. o Only 3G. Modem communicates only in 3G. o Only 4G.
  • Page 26: Settings. Web

    Ethernet configuration tab allows setting up IP information for Ethernet ports. Right column displays current active setting. It refreshes every 5 seconds. Please change IP addresses responsively, do not lock yourself out from access to DC12U management. Figure 4.19. Ethernet settings page 4.3.2 Settings.
  • Page 27 DC12 PLC Data Concentrator User Manual automatically redirected to enabled protocol and port. Default protocol and port for WEB UI access is HTTP over port 80. Protocol and port settings applies to all interfaces - Ethernet and GSM. Do not lock yourself out of management.
  • Page 28: Firmware Update

    Figure 4.23. User management page 4.3.3 Firmware update DC12U can be upgraded via WEB UI. It is not possible to downgrade DC12U software via WEB UI. If there was any critical error in upgrade process DC12U will revert to last good firmware.
  • Page 29 • Admin user must upload update package to DC12U and initiate upgrade. • DC12U will check package contents. If file was received correctly and it is newer than current version, DCU will start upgrade process. • No user interaction is needed during upgrade process. DCU will not reboot while upgrading or after upgrade.
  • Page 30: Dcu Configuration Using Dc Configurator

    DC12 PLC Data Concentrator User Manual 5 DCU Configuration using DC Configurator 5.1.1 Supported Operating systems DC Configurator application, further referred to as Configurator, can run on Microsoft Windows XP, 7, 8, 10 operating systems. Please update Microsoft .NET3.5 libraries if needed. Libraries are available from Microsoft and not included in DC Configurator distributable.
  • Page 31: Upgrading Dc Configurator Application

    DC12 PLC Data Concentrator User Manual On the left is located window (Named Managed device list) with list of devices managed by DC Configurator application. All added DCUs are listed under Devices folder. Main application window is located on the right. All controls and management tabs are located in this window.
  • Page 32: Dcu Parameters

    DC12 PLC Data Concentrator User Manual 5.3 DCU parameters Select desired DCU in managed device list. Press Connect in Main application window. You should see in [2020.03.25 11:25:55] [INFO] DC12U_Kaunas : Connected (admin Log window: – ReadWrite) if connection was successful. Then you must read configuration from DCU. Press Read configuration in Main application window.
  • Page 33 DC12 PLC Data Concentrator User Manual Figure 5.3. DCU options configuration DCU Software. This option shows version of requester working in DCU. In order to read it from DCU press Get DCU Software Info. Following DCU requester parameters can be set: •...
  • Page 34: Dcu Settings Tab

    DC12 PLC Data Concentrator User Manual 5.3.3 DCU Settings tab System Info tab displays DCU information. • Host Name – DCU full name consisting of manufacturer code, device type and serial number. I.e. EGM0990000000006 • HW version – DCU hardware version. Displayed as number. •...
  • Page 35 DC12 PLC Data Concentrator User Manual • Min Poll – the minimum poll interval for NTP messages. Setting takes a time value (in seconds). Must not be smaller than 16 seconds. Default value 32 seconds. • Max Poll – the maximum poll intervals for NTP messages. Setting takes a time value (in seconds). Must be larger than MinPoll.
  • Page 36 DC12 PLC Data Concentrator User Manual Figure 5.6. GSM settings page Modem info. GSM modem module status. Connected if module is present and working. It does not indicate active data connection, only connection to mobile network. • IMEI - International Mobile Equipment Identity, unchangeable code identifying modem module.
  • Page 37: Fw Update Tab

    DC12 PLC Data Concentrator User Manual Figure 5.7. Local Area Network settings page • Status – Link status. Activated means port is connected to network. Unavailable means no link is available on given port. • IP address – IPv4 address for given network interface. Default IP addresses are 10.0.2.1 for Ethernet 0 and 10.0.2.2 for Ethernet 1.
  • Page 38: Meter Tariff Modification Tab

    DC12 PLC Data Concentrator User Manual Figure 5.8. Firmware update page Meter Firmware update. Please select provided meter firmware file, select meters, which will be upgraded, and time when firmware has to be activated. If activation timer is not set, firmware will be activated (meter will reboot) right after successful firmware transmission to meter.
  • Page 39 DC12 PLC Data Concentrator User Manual Figure 5.9 Meter tariff modification page At the top of the table, hourly rates that are valid for the current date are displayed. Moving through the list of meters, in the lower part on the Active tab, displayed detailed configuration of the active tariff for the selected meter.
  • Page 40 DC12 PLC Data Concentrator User Manual Figure 5.10 Editing meter tariff table MeterTarif.xml After editing the tariff, click the Create tariff XML button, in this case the file will be created in the temporary folder on the disk, the program will switch to the Update by template tab, and the created file will be substituted in the field with the name of the update file.
  • Page 41: Meter Parameter Update Tab

    DC12 PLC Data Concentrator User Manual After that, in the list of meters for updating select one or several meters, to record a new tariff schedule and click Start update. When updating the tariff on the meter, the outdated data on the meter’s tariff schedule is deleted from the controller’s database.
  • Page 42 DC12 PLC Data Concentrator User Manual • Active – If meter is made inactive, then DCU will not read any data from that meter. Figure 5.13. Available meters list For each meter available on DCU additional configuration can be set. Please select meter and press Edit in Meters menu.
  • Page 43 DC12 PLC Data Concentrator User Manual Figure 5.14. Meter parameters configuration It is possible to connect directly to selected meter via Work with meter menu. All data and settings under this menu is read and written directly to the meter. Because connection is between managing station and DCU, then from DCU to meter via PLC, reaction time for each action can be slow.
  • Page 44: Controller Data Inspector

    Controller name – User configurable DCU name. • Serial number – DCU serial number. Set at the factory, can be modified by manager if needed. • Controller type – DC12U is only PLC controller. • Call number – parameter set to 1. •...
  • Page 45 DC12 PLC Data Concentrator User Manual Figure 5.16. Controller data inspector Full meter table with detailed PLC information is available under Work with controller submenu. Additional window will be opened. After Pressing Read Meters Table, it will be read from DCU PLC meter list.
  • Page 46 DC12 PLC Data Concentrator User Manual Figure 5.17. Meter PLC connection information Right clicking on any meter allows removing meter from DCU PLC list. White list is used to allow only listed meters to be able to register to DCU. By default it is disabled, any meter is allowed to register on DCU via PLC.
  • Page 47 DC12 PLC Data Concentrator User Manual Figure 5.19. Blacklist management Please consider the environment before printing this document.
  • Page 48: Dcu Sms Management

    DC12 PLC Data Concentrator User Manual 6 DCU SMS management 6.1 SMS management configuration in WEB UI In order to control DCU via SMS, feature has to be enabled. In WEB UI go to Settings > System and open GSM tab. Set Control via SMS to enabled. Set Password, It has to be 8 symbols long. Figure 6.1 SMS management in web ui 6.2 SMS Commands from phone.
  • Page 49: Sms Command Examples

    DC12 PLC Data Concentrator User Manual PASSWORD Set password for authentication with GSM operator. By default it is empty. Password is case sensitive. AUTH Set authentication mode: [NONE/PAP/CHAP]. By default all modes are enabled. Setting authentication mode overrides previous setting. MODE Set network mode: •...
  • Page 50: Appendix A. Data Gathered By Dc12U From Meters

    DC12 PLC Data Concentrator User Manual Appendix A. Data gathered by DC12U from meters Data Concentrator Unit (DCU, DC12U) collects the following data from GxY electricity meters: Energy registers (total and by tariff), captured at the end of each day at 00:00 o‘clock OBIS 15.8.0...
  • Page 51: Appendix B. Gsm Led Description

    DC12 PLC Data Concentrator User Manual Appendix B. GSM LED description • LED 1 [Power] – RED. Connected directly to power supply • LED 2 [Network] – RGB LED. o LED 2.1 – Red, o LED 2.2 – Green, o LED 2.3 – Blue. •...
  • Page 52: Appendix C. Dc12U Dimensions And Installation

    DC12 PLC Data Concentrator User Manual Appendix C. DC12U Dimensions and installation. Data concentrator injects PLC signal in to all three phases simultaneously. For data concentrator installation 3 Phases (L1, L2, L3) and Neutral line should be used. DCU wiring diagram provided on DCU nameplate and in Figure 0.1.
  • Page 53 Figure 0.3. Screws used in DCU Figure 0.4. DCU Terminal block contact dimensions It is possible to mount the DC12U to the wall or cabinet by means of 5x20mm screws. Mounting holes illustrated in Figure 0.5. DCU mounting holes. Please consider the environment before printing this document.
  • Page 54 DC12 PLC Data Concentrator User Manual Figure 0.5. DCU mounting holes After installation, sealing points of the DCU should be checked and sealed if necessary. Sealing points of two-position main cover and module cover (suspended seal) are indicated in Figure 0.6. Sealing points. For sealing, up to 2 mm diameter sealing cord can be used.
  • Page 55 DC12 PLC Data Concentrator User Manual Figure 0.6. Sealing points Terminal cover has removable edges for connecting cables, and two sealing screws are inserted inside terminal cover. Figure 0.7. Terminal cover Please consider the environment before printing this document.
  • Page 56 DC12 PLC Data Concentrator User Manual End of Document Please consider the environment before printing this document.

Table of Contents