Remote cut off switch

Advertisement

Quick Links

Remote Cut Off Switch „NEFA 20-plus F/1"
Issue 01.01.2014
Installation:
1. Turn off the breaker of the desired cicuit
2. Install the NEFA 20-plus F/1 in a seperate electrical box according to the above shown wire diagram and electrical code.
3. After installing the receiver switch ,mount the antenna on top of the box and connect to the socket to the bottom.
•Note: Antenna must not be obstructed
4. Plug in the control light (included in scope of supply) into a visible recepticle in the monitored circuit and test for proper
function of the switch.
5. Stick the yellow warning sticker with breaker number and circuit name on the fuse box and on the box were the Remote
Cut Off Switch is installed,as well as on all monitored outlets
Safety features:
The NEFA 20-plus F/1 has an integrated electronic breaker to protect itself (not a replacement for the
regular breaker of the circuit). In the case of lightning or surge the F/1 shuts off. To reset the proper function turn the main
breaker for that circuit off for 30 seconds and on again. This resets the integrated breaker of the F/1 and brings it back to its
normal function.
Remote control unit: Small dimension handheld RF transmitter with HCS rolling code encoder. High security level, safe and
easy to use. The RF transmitter allows the user to manually turn on or off desired circuits. By pressing the blue button the
unit sends a short analog signal to the base unit and turns desired circuits on or off. Low energy consumtion lithium battery.
Warranty: We grant a 5 year long term warranty on the NEFA 20-plus F/1.
Technical Data
Operating Voltage:
120VAC
Continuous load:
20 Amp
Own consumption:
<1,6 Watt
Size:
1.34 Inch x 2.36 Inch x 3.54 Inch WxHxL
Sensitivity:
10 micro Volt, Transmitter BZT, FCC,
Industry Canada approved
Safe Living Technologies Inc. Tel: (519) 240-8735
S A F E
L I V I N G
Technologies Inc.
C r e a t i n g
H e a l t h y
L i v i n g
Installation Guide
The Remote Cut Off Switch NEFA 20-plus F/1 must be installed by a licensed electri-
cian according to the electrical code of each Province (Canada) or State (USA).
The switch is added to an existing circuit just after the circuit breaker and switches the
hot or black wire in that circuit. The switch is mounted in its own, separate approved
electrical box beside the main panel or a sub panel. Please note that the circuit will still
be protected by the circuit breaker. The switch is by no means a circuit breaker replace-
ment but an additional in-line device. Each switch controls a single circuit.
For proper connections see schematic drawing on top.
Transmitting power:
Control light:
In case of failure:
Battery remote control:
Long term warranty:
Mounting:
www.SLT.co
sales@SLT.co
subject to modifications and amendments errors excepted
S p a c e s
5 mW, 915.5 MHz, coded
green = Operating Power „ON"
Manual switching without remote control
Li CR 2032
5 Years
Seperate electrical box beside the breaker
panel
Biologa
Model No.: NEFA 20 PLUS F/1
IC: 6454A-NEFA20F1
FCC ID: TZE-NEFA16PLUSF-1
* This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must accept
any interference received, including interference that may cause
undesired operation.
Page 1

Advertisement

loading

Summary of Contents for Safe Living Technologies NEFA 20-plus F/1

  • Page 1 1. Turn off the breaker of the desired cicuit 2. Install the NEFA 20-plus F/1 in a seperate electrical box according to the above shown wire diagram and electrical code. 3. After installing the receiver switch ,mount the antenna on top of the box and connect to the socket to the bottom.
  • Page 2 C r e a t i n g H e a l t h y L i v i n g S p a c e s Circuit diagrams „NEFA 20-plus F/1“ Ausgabe 01.01.2014 Installation with all loads 20A-7500VA (ohmic load)