System Components IML-RESI PD-Series Handle Control Unit Battery 45° Adapter Additional Handle Navigation Knob Display Bluetooth Antenna USB Interface...
Switching the device On and Off IML-RESI PD-Series Press the navigation knob to switch on the instrument and keep it pres- sed until the IML logo appears in the display. Press the navigation knob again to switch off the device. Keep it pres- sed until the control unit switches off.
Description of the Main Menu IML-RESI PD-Series Number of stored Feed stage measurements Feed speed Remaining free memory Tilt (Add-on module TLT) Changes the ID number. You Changes the remark. You can choose for example a can choose an individual tree number.
Page 5
Feed and RPM Stages IML-RESI PD-Series General Feed Stages: General RPM Stages: Hard wood: Hard wood: Stage 2 (50 cm/min) 2500 RPM to Stage 4 (175 cm/min) Soft wood: Soft wood: Stage 3 (100 cm/min) 2500 RPM to Stage 5 (250 cm/min)
Page 6
Changing the Drilling Needle IML-RESI PD-Series In order to change the drilling needle, select the drilling needle symbol in the main menu. The menu shown above appears. For automatic needle change select ‚AUTO‘ for manual needle change select ‚MANUAL‘. If no needle breakage or telescope damage exists always select the automatic needle change.
Page 7
Furthermore the next service date, the versions of the firmware, of the hardware and of the WoodInspector are listed. The installed Add-on modules are also displayed in the device information menu. Note: The complete instruction manual is available on our website: www.iml.de/en You can find it in the download area.