Hydraulic calibration pump
Hide thumbs Also See for 7095:

Advertisement

User Manual
7095
Hydraulic Calibration Pump
Version 1.2
March 2021
Time Electronics Ltd
Unit 5, TON Business Park, 2-8 Morley Road,
Tonbridge, Kent, TN9 1RA, United Kingdom.
T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198
mail@timeelectronics.co.uk | www.timeelectronics.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7095 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Time Electronics 7095

  • Page 1 User Manual 7095 Hydraulic Calibration Pump Version 1.2 March 2021 Time Electronics Ltd Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom. T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 mail@timeelectronics.co.uk | www.timeelectronics.com...
  • Page 2 All rights reserved. Nothing from this manual may be multiplied, or made public in any form or manner, either electronically or hard copy, without prior written consent from Time Electronics Ltd. This also applies to any schematics, drawings and diagrams contained herein.
  • Page 3: Table Of Contents

    Time Electronics User Manual 7095 Hydraulic Calibration Pump v1.2 Contents Introduction ............................ 4 Specifications ..........................5 Kit Contents ........................... 5 Operational Guidelines ......................... 6 Operation ............................7 Warranty and Servicing ......................... 8 7095 Hydraulic Calibration Pump Page 3 of 9...
  • Page 4: Introduction

    The 7095 is supplied as a kit with a minimess 1/4" BSP high pressure hose, 1/4" BSP blanking plug, selection of spare washers, filters and o-rings, carry case, and user manual.
  • Page 5: Specifications

    Time Electronics User Manual 7095 Hydraulic Calibration Pump v1.2 Specifications Output Range: 0 to 700 bar (0 to 10,000 psi) Media: Distilled water or mineral based hydraulic oil. Gauge Port: 3/8” BSP (blanking plug fitted) Process (UUT) Port: 1/4” BSP with minimess test point fitted...
  • Page 6: Operational Guidelines

    4. The 7095 comes with a 3/8” BSP gauge port fitted with a blanking plug and a 1/4" BSP output port fitted with a capped Minimess 1620 test point.
  • Page 7: Operation

    2. Connect the Minimess hose to the Minimess adaptor on the output port and connect to the instrument under test. 3. Connect the calibrator with a suitable adaptor to the 7095 via the top gauge port. 4. Set the vernier control to about half its travel and fully screw in the release control valve, no need to over tighten.
  • Page 8: Warranty And Servicing

    Time Electronics’ total liability is limited to repair or replacement of the product. Note that if Time Electronics determine that the fault on a returned product has been caused by the user, we will contact the customer before proceeding with any repair.
  • Page 9 Returning Instruments Prior to returning your product please contact Time Electronics. We will issue a return merchandise authorization (RMA) number that is to accompany the goods returning. Further instructions will also be issued prior to shipment. When returning instruments, please ensure that they have been adequately packed, preferably in the original packing supplied.