To read out the status of power outlets from your computer, enter the command
as explained below:
Syntax of the command:
Parameter
Value
Function
X
1 to 16
means the address of the Satellite (see table §1)
Y
1 to 8
indicates the number of the power outlet you want to control
The 8XS then sends the status of the specified power outlet using following syntax:
Pxy=z<CR><LF>
z = 0 if the power outlet is off
z = 1 if the power outlet is on
<CR> = Carriage Return
<LF> = Line Feed
Examples:
Read out the status of the power outlet 5 of the Satellite with address 1:
R15 <ENTER>
Read out the status of the power outlet 6 of the Satellite with address 2:
R26 <ENTER>
Remark: The 8XS accepts lower case and upper case commands.
ELECDAN • 2 impasse de la noisette • 91370 VERRIERES-LE-BUISSON • FRANCE
Tél. +33 (0) 1 60 11 44 44 • Fax +33 (0) 1 69 20 39 63 • www.elecdan.com • sales@elecdan.com
Rxy <ENTER>
ELECPS
-
8XS
ELECPS
-
8XS
Quick Start Guide
Detailed information can be found in the
User Guide on the provided CD-ROM
L'ELECPS-8XS-EU
Satellite is a power distribution and control unit that enables
power management of 8 devices through an RS-232 or RS-485 serial connection.
The number of controlled power outlets can be extended up to 128 by cascading
up to 16 Satellite models.
This 8XS is ideal to control power outlets through the serial connection of a PC, a
KVM switch or a console server. It can also be connected to an 8XM Master to
extend the number of controlled power outlets over IP.