Assembly instructions Changing table Elise wall mounted with and without sink.
(Item.nr 119366, 119367, 35441, 35442 and 35446)
The changing table must be mounted on a free surface without nearby fixed obstacles on the
walls.
The floor must be stable and leveled.
Position the changing table so that there is no risk of squeezing adjacent objects. It is the
installer and the user's responsibility to position the changing table so that there is no risk of
squeezing. Remember that you as a user are responsible for ensuring that no one is harmed.
The distance to adjacent objects should be as following:
- No openings between 7 and 12 mm
- No openings between 25 and 45 mm
- No openings between 65 and 223 mm
The changing table must be mounted as low as possible.
The adjustable feet on the stand are there to make it easier to get the changing table in
balance (horizontal position).
Electrical connection must be made via a standard 230V socket with timer.
This equipment must not be permanently connected to the mains.
Water and drains must be connected by a qualified installer.
The table must not be loaded with more than a maximum of 40kg in the
stationary position and 20kg in the driving position.
Ladder shall not be mounted due to low minimum height.
If any part of the changing table is damaged or if there is a suspicion of
damage, take the changing table out of operation immediately.
Disconnect the power supply and contact your supplier.

Use

The table is intended for care, laundry, diaper changes, etc. of small children in kindergartens,
preschools and similar functions.
All other use is prohibited and falls outside the product / supplier's product
liability.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 119366 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lekolar 119366

  • Page 1 Assembly instructions Changing table Elise wall mounted with and without sink. (Item.nr 119366, 119367, 35441, 35442 and 35446) • The changing table must be mounted on a free surface without nearby fixed obstacles on the walls. • The floor must be stable and leveled.
  • Page 2 Assembly 1. Mount the stand on a wall where there are studs. NOTE! Plaster or similar sheet material does not hold as a fastening material. If there are no studs, additional stud framing needs to be done. 2. Adjust the changing table with the help of the adjustable feet’s. 3.
  • Page 3 5. Connect the hand control to the designated socket in the control box. 6. Connect the 220V cable (the length of the power cord is 3.7m) to test that the motor works. 7. Then unplug the 220V cable. 8. A. Route cables (220V and hand control) on the appropriate side, right or left. Use the available bushings.
  • Page 4 11. Water and sewage shall be connected by a qualified installer. Water and sewage are drawn according to this sketch out through the hole located on each side of the table. (The length of the drain hose is 1.8 m) 12.
  • Page 5 Operation Hand control with up & down buttons illustrated with arrows regulates the movement of the table. Raise button. Press the up button until the table reaches the desired position. Button for lowering. Press the down button until the table reaches the desired position. Squeeze protection / safety stop The function of the safety stop is such that if the underside of the table (clamp protection plate) is affected "Push upwards"...

This manual is also suitable for:

119367354413544235446

Table of Contents