These instructions are designed for the installation
engineer to assemble the product and for the user
to operate and maintain it.
After installation, please pass them on to the
user for safekeeping.
Symbols and their meaning
Caution! Warning against bodily injury or damage
to property.
Note, tip or reference
Incorrect installation
Correct installation/test of functionality
Observe installation details
Cold water
Water fl ow
Optional/accessories

Safety Information

– This device is not intended to be used by per-
sons (including children) with limited physical,
sensory or mental abilities, or with inadequate
experience and/or knowledge, unless they are
supervised by somebody responsible for their
safety and have received instructions from them
on how to use the device.
– Children must be supervised to ensure they do
not play with the device.
– Avoid contact with the eyes or mucous membra-
ne.
– The electrical installations must be undertaken
by a specialist electrical installer in compliance
with IEC 60364-7-701/VDE 0100 Part 701!
National and local regulations must be taken into
consideration!
– Do not start the appliance if it or the power sup-
ply cable is damaged, but have it replaced by
the manufacturer, its customer service or by an
equally qualifi ed person.
Intended use
Sensor washbasin mixer for use in private and
public bathrooms and WCs.
Operation possible with pressure tanks and ther-
mally and hydraulically controlled instantaneous
water heaters.
Operation with unpressurised tanks (open water
heaters) is not possible!
Operation only with potable water.
Important information, please make sure to read!
Hot water
No water fl ow
With the optional Bluetooth® adapter (article No.:
59911 000000) the sensor washbasin mixer can
be operated and programmed via app.
Product is only suitable for installation indoors!
Attention! Only install in frost-free places.
Declaration of conformity! This product complies
with the requirements of the valid EU Guidelines.
The declaration of conformity for this product can
be requested from the following address:
KEUCO GmbH & Co. KG, Oesestraße 36,
D-58675 Hemer.
Technical specifi cations
– Supply voltage:
- Secondary voltage:
– Max. Power consumption
– Ambient conditions:
Temperature
– Flow at 3 bar pressure:
– Pressure:
min. 0.5 bar/recommended 1-5 bar
– Operating pressure
– Test pressure:
– Recommended hot water inlet temperature:
– Water connection:
Avoid pressure diff erences between the cold and
hot water feeds.
Install a pressure reducer for static pressures
above 5 bar.
Factory settings
– Cleaning mode:
– Continuous water fl ow
(thermal disinfection):
– Detection zone:
– Automatic fl ushing:
– Run-on time:
– Water stop:
*= Value can only be adjusted using the KEUCO
Bluetooth app with the optional Bluetooth® adapter
(article No.: 59911 000000).
EN
220V-240V AC 50Hz/60Hz
6.75 V DC
2.5 W
5°– 40° C
max. 3.8 l/min
max. 8 bar
16 bar
max. 70°C
cold = blue marking
hot = red marking
180 s
2 min
~16 cm (factory setting)
deactivated
(factory setting)
30 s*
1 s
7