Belt-Way Scales ASM0325 Quick Start Manual

Remote display

Advertisement

Quick Links

R
D
Q
S
G
2.5
2021
EMOTE
ISPLAY
UICK
TART
UIDE V
Belt-Way Scales Inc.
1 Beltway Rd.
Rock Falls IL 61071
Phone: (815) 625-5573
sales@beltwayscales.com
www.beltwayscales.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASM0325 and is the answer not in the manual?

Questions and answers

Summary of Contents for Belt-Way Scales ASM0325

  • Page 1 2021 EMOTE ISPLAY UICK TART UIDE V Belt-Way Scales Inc. 1 Beltway Rd. Rock Falls IL 61071 Phone: (815) 625-5573 sales@beltwayscales.com www.beltwayscales.com...
  • Page 2: Table Of Contents

    Remote Display Quick Start Guide v2.5 Table of Contents 1. INTRODUCTION ..........................2 2. WHAT'S IN THE BOX ........................2 3. DISPLAY SPECIFICATIONS ......................3 4. INSTALLATION PROCEDURE ......................3 5.NETWORK SETUP ..........................4 6. DISPLAY NETWORK SCREEN ......................5 7.
  • Page 3: Introduction

    Remote Display Quick Start Guide v2.5 Introduction The 4" or 7" Belt-Way Remote Display allows a plant operator to monitor multiple conveyor belt scales from a single location. The operator can reset scale totals and perform zero calibrations on all connected scales. The remote display also displays historical production information and records accumulated weight and flow rate data files to the included USB flash drive.
  • Page 4: Display Specifications

    Remote Display Quick Start Guide v2.5 Display Specifications Part Numbers: ASM0325 4” Remote Display ASM0294 7" Remote Display ASM0294-BASIC 7” Basic Remote Display Display Communication Screen: 4” or 7” Color Touchscreen Com ports: Ethernet Max colors: 16 Million Data Storage: 128 MB Internal Resolution: 4"...
  • Page 5: Network Setup

    Remote Display Quick Start Guide v2.5 Step 2B: HARDWIRE ONLY Connect CAT5e cable directly to the Display Use coupler to bypass the Power over ethernet adapter. WHITE CABLE CAT5 CABLE TO DISPLAY TO NETWORK Step 3: Power the display. The display comes with a 110/220 AC to 24 VDC power supply. Plug the power cord into a grounded outlet.
  • Page 6: Display Network Screen

    Remote Display Quick Start Guide v2.5 Hardwire Network Example: Remote Display 192.168.1.251 Scale 1 192.168.1.100 Ethernet Switch Scale 2 192.168.1.101 Scale 3 Network Device 192.168.1.102 Running VNC VIEWER Cat5e cable segments MUST be less than 300 ft Display Network Screen The Network screen shows scale IP addresses currently programmed into the display.
  • Page 7: Integrator Ip Address Setup

    Remote Display Quick Start Guide v2.5 Integrator IP Address Setup Program the IP address and Slave ID into each integrator. The first scale is usually left at the default address 192.168.1.100. Each additional scale must be changed to 192.168.1.101, 192.168.1.102, etc. Arrow down to IP Address Next choose Ethernet Press the MENU Button and...
  • Page 8 Remote Display Quick Start Guide v2.5 Main Screen part 2 Scale Connection Status Indicator Each scale has a connection indicator. The indicator is GREEN when the scale is connected and the data is updated. The indicator is when the scale is not connected and displayed data may not be updated to the most current values.
  • Page 9: Menu

    Remote Display Quick Start Guide v2.5 Step 2: Press OK to confirm and proceed with the ZERO CALIBRATION. Step 3: green Each indicator turns displays RUNNING. They automatically return to normal when each scales ZERO CALIBRATION process completes. THE ZERO CALIBRATION SHOULD BE PERFORMED A MINIMUM OF ONCE PER DAY OR AS NEEDED DEPENDING ON WEATHER CONDITIONS, BELT CONDITIONS, MECHANICAL CHANGES TO THE CONVEYOR, ETC.
  • Page 10: Cal Data

    Remote Display Quick Start Guide v2.5 Cal Data The Cal Data Screen shows important calibration information including Previous Trim Factor, Current Trim Factor, Trim Factor Difference, Previous Zero Value, Current Zero Value, and Belt Length. The Zero Value changes each time the Zero Calibration is performed.
  • Page 11: Setup

    Remote Display Quick Start Guide v2.5 Setup Setup shows the current version of the remote display software. Example: 7.3.06 (7" Display, Version 3.06) There is also an automatic restart feature that should be activated if the display is powered continuously for 24 hours per day. The restart time should be a few minutes before the normal plant start-up time.
  • Page 12: Reports

    Remote Display Quick Start Guide v2.5 Total Production, TPH, and Belt Speed Reports THIS FEATURE IS NOT AVAILABLE IN THE BASIC DISPLAY The graphing screens show the trend of accumulated weight, tons per hour, or belt speed over time. The readings are logged once per minute. Each graph is independently scaled using the Max button.
  • Page 13: Usb

    Remote Display Quick Start Guide v2.5 *THIS FEATURE IS NOT AVAILABLE IN THE BASIC DISPLAY* The USB screen shows the remaining capacity for the display's internal memory and the USB flash drive. The data log files are saved to the internal memory and backed up to the USB flash drive each day at 12:00 pm.
  • Page 14: Vnc Viewer

    Remote Display Quick Start Guide v2.5 VNC VIEWER THIS FEATURE IS NOT AVAILABLE IN THE BASIC DISPLAY* The remote display can be monitored from one or two PC's, smart phones, or tablets running VNC VIEWER (Virtual Network Computing) software. VNC Viewer is an inexpensive program that can be downloaded from www.realvnc.com, the Itunes App store or Google Play App store.
  • Page 15: Software Update

    Remote Display Quick Start Guide v2.5 Download Software Update Updates to the display can be downloaded from the USB drive. The update files are emailed from Belt-way as Zip files. Step 1: Remove the USB drive from the display and plug it into the computer. Download the Zip file from the email and save it on the USB drive.
  • Page 16 Remote Display Quick Start Guide v2.5 Step 3: Click Extract here. Follow the steps to save the Zip file as a new folder on the USB drive. Step 4: Right click on the USB drive and choose Eject. Remove the USB drive from the computer. Step 4: Insert the USB drive into the display USB port.
  • Page 17 Remote Display Quick Start Guide v2.5 Step 5: Use the keyboard to enter the default password of "1". Step 6: The Pick a Directory window appears. Double click the usbdisk folder. Double click the disk_a_1 folder. Single click to highlight the update folder and click Ok. The display will automatically restart and run the new program.