Download Print this page
Profelmnet 2114 Quick Start Manual

Profelmnet 2114 Quick Start Manual

Control panel for double motors up to 1600 watt

Advertisement

Quick Links

2114
Control panel for double motors up to 1600 watt
Code
Frequency
PSR/PTR-2114
433,92/868,3
PS-2114
433,92
PSR/PTR-2114P
433,92/868,3
Check all connections. Check the terminal switches of the motor. The BLUE/GREY motor wire is connected in terminal 4.
Δύναμη μοτέρ
Χρόνος αργού
Πυκνωτής Πυκνωτής
1 2 3 4 5 6 7 8 9 10 11 12
GND
L N
'
Φάρος
230VAC
230VAC
Motor
Motor
1
Terminal
Codification
Switches
Keeloq roll
YES
Standard
YES
Profelmnet roll
YES
Χρόνος διαδρομής
Κωδικός
M1
M2
"
+
Ενδεικτικά
"
Τροφοδοσία
Kωδικός
+
Προγράμματα
ON
1 2 3 4 5 6 7 8
1
8
Mοτέρ 1 Mοτέρ 2
24 25 26 27 28 29
Τερματικοί διακόπτες
1 2 3 4 5 6
Ενδεικτικά λειτουργίας
13 14 15 16 17 18 19 20 21 22 23
0 +
12V
κ
λειδαριά
φωτοκύτταρα
2
εξωτερικά μπουτόν
Photocells
Ext.Button
YES
YES
YES
YES
YES
YES
Function description
Νο
OFF: NO terminal switches. In case of single swing gate or
rolling shutter.
1
ON: Terminal switches. In case of sliding gate or barrier.
OFF: No photocell 2.
ON: Photocell 2. (Internal 1m after the fully open position to
2
stop the motion.)
OFF: No photocell 1.
3
ON: Photocell 1. (On the door for safety and auto-close.)
OFF: No auto close
ON: Auto-close. There is a double counter in the A/C
function. The first one is 120 seconds and is applied when
the door stops after an open function. During this counting
4
time of 120 sec., if the photocell beam is disturbed, then
after the beam is free, the A/C counting time becomes 10
sec. until the fully closed position.
OFF: No delay between two motors.
5
ON: Delay between Motor 1 (first) and Motor 2 (second)
OFF:NO repeatable close.
6
ON: Repeatable close for 1 sec every 1 hour
Κεραία
OFF: No key-lock
ON: Key-Lock (activates the key-lock
7
12
V
OFF: NO Light flash
8
ON: Light FLASH (OFF), or constant 2min. (ΟΝ)
Ag.Dimitriou 286A ,173 42 Agios Dimitrios
Call center: 210 9850 244, Fax: 210 9823 264
www.profelmnet.com
Light
Auto close
230V
YES
YES
YES
YES
YES
YES
routine)
Motor
Slow move
torque
YES
YES
YES
YES
YES
YES

Advertisement

loading

Summary of Contents for Profelmnet 2114

  • Page 1 Ag.Dimitriou 286A ,173 42 Agios Dimitrios Call center: 210 9850 244, Fax: 210 9823 264 www.profelmnet.com 2114 Control panel for double motors up to 1600 watt Terminal Light Motor Code Frequency Photocells Ext.Button Auto close Slow move Codification Switches 230V...
  • Page 2 Ag.Dimitriou 286A ,173 42 Agios Dimitrios Call center: 210 9850 244, Fax: 210 9823 264 www.profelmnet.com Functions Motor torque for both: photocell beam is disturbed, then after the beam is free, the A/C counting time becomes 10 sec. until the fully closed Adjust the motor torque for both motors at ½...

This manual is also suitable for:

Psr-2114Ptr-2114Ps-2114Psr-2114pPtr-2114p