Setup Changes with DIP Switch 1 ON - Using a TP600 or TP400 Panel (cont.)
Again, you will have 1 minute to complete the setup change after you manually exit Priming Mode.
Immediately after exiting Priming Mode, press this sequence of buttons: Warm*, Light, Warm, Warm, Warm, Warm. Continue
to press Warm until the display shows the Setup Number (S-01, S-02, etc.) you want to switch to. When the correct setup
number is showing, press Light once, and the system will reset, using the newly-selected Setup from that point on.
Move DIP Switch 1 to the OFF position to take the spa out of Test Mode. °F or °C will replace °T.
Using a permanent marker, write the Setup number on the Setup label mounted inside the system lid (right). This is very
important to any service person in the future who may need to replace a circuit board or system and needs to
change the Setup on a replacement part while in the field.
NOTE: Changing the Setup may require wiring changes as well - refer to the wiring diagram or wiring diagram
addendum.
Main Screen
*If the Control Panel does not have a Warm (Up) button, but rather a single Temp button, use the Temp button in place of the Warm
button in the instruction above. (The flow chart assumes a single Temperature Button.)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
42217 C
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message - every 1/2 second
A temperature button, used for "Action"
Light or dedicated "Choose" button, depending on control panel configuration
Waiting time - varies depending on function
While the Set Temperature is
still flashing, press Light
TEST will now appear in
the LCD first.
Displays Fault Log
The System will reset and go into Priming Mode if the Light Button
is pressed while anything other than the current setup is flashing.
If there is no change to the Setup Number (S-01, S-02, etc.),
the display returns to the SETP screen.
Several Setups can
exist in in this string
A dash (--) indicates the current Setup.
When set to ON, Panel will display
alternate readings from
Senor A and Sensor B
on Main Screen
THIS SYSTEM IS
CONFIGURED AS
SETUP #
or
Approx.
5 sec.
or
Approx.
5 sec.
Main Screen
39