hopf 4800 Series Technical Manual

Signal converter

Advertisement

Quick Links

Industriefunkuhren
_____________________________________________________________
Technical Manual
Signal Converter
for DIN Rail Mounting
Series 4800xx-yy
ENGLISH
Version: 01.02 - 07.06.2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4800 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for hopf 4800 Series

  • Page 1 Industriefunkuhren _____________________________________________________________ Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.02 - 07.06.2021...
  • Page 2 2 / 23 Signal Converter 4800 - V01.02 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 3 Disregard may impact function of system/device. Information Notes and Information. Signal Converter 4800 - V01.02 3 / 23 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 4 - and may be released for sale within the common markets. 4 / 23 Signal Converter 4800 - V01.02 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 5: Table Of Contents

    5.2 Switch on the Operating Power Supply..............18 Signal Converter 4800 - V01.02 5 / 23 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 6 6.7 Dimensions - DIN Rail Housing ................23 6 / 23 Signal Converter 4800 - V01.02 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 7: Signal Converter Series 4800

    Power supply unit with power LED • Completely maintenance-free • Customer-specific converter option Signal Converter 4800 - V01.02 7 / 23 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 8: Overview And Connections

    RS422 interface. 8 / 23 Signal Converter 4800 - V01.02 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 9: Rs422/Rs232 Connection

    AC or DC (see Chapter 4 Power Supply). Signal Converter 4800 - V01.02 9 / 23 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 10: Optocoupler Connection

    OC3+ n.c. OC2- OC1+ n.c. = not connected 10 / 23 Signal Converter 4800 - V01.02 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 11: Optical Fiber Connection

    RxD - green) which displays the current operating status of the transmission and reception lines. Signal Converter 4800 - V01.02 11 / 23 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 12: Rs422 Connection

    = not connected 12 / 23 Signal Converter 4800 - V01.02 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 13: Housing Installation

    Push the module upwards and then tip forward to remove from the rail. Signal Converter 4800 - V01.02 13 / 23 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 14: Power Supply

    In doing so the respective country-specific regulations (e.g. VDE, DIN) must be observed. 14 / 23 Signal Converter 4800 - V01.02 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 15: Power Supply Unit Specifications

    0.5 – 0.6 L, N, 0.2-2.5 0.2-2.5 24-12 Signal Converter 4800 - V01.02 15 / 23 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 16: Voltage Input / Fuse Protection

    No power supply is available or the device is faulty. 16 / 23 Signal Converter 4800 - V01.02 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 17: Dc Power Supply - Power Supply Unit Dc-M03-D

    No power supply is available or the device is faulty. Signal Converter 4800 - V01.02 17 / 23 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 18: Commissioning

    P E = Switch on the external power supply source. 18 / 23 Signal Converter 4800 - V01.02 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 19: Technical Data

    Interference radiation: EN 55022 EN 55022 Class B Signal Converter 4800 - V01.02 19 / 23 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 20: Ac - Power Supply

    Function Display (Power LED) LED green LED green 20 / 23 Signal Converter 4800 - V01.02 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 21: Dc - Power Supply

    Pay attention to the optical output power or received power when using other optical fiber types. Signal Converter 4800 - V01.02 21 / 23 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 22: Rs232/Rs422 Signal Inputs/Outputs

    150 / 100µsec. at 20mA switching current Isolation voltage: 500VDC 1000M min. 22 / 23 Signal Converter 4800 - V01.02 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
  • Page 23: Dimensions - Din Rail Housing

    ECHNICAL Dimensions - DIN Rail Housing Signal Converter 4800 - V01.02 23 / 23 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...