Do you have a question about the turbofan EH Series and is the answer not in the manual?
Questions and answers
Summary of Contents for Moffat turbofan EH Series
Page 1
E H T 1 0 H u m i d i f i e d H o l d i n g C a b i n e t I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l 245286-1...
Page 2
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in writing by the manufacturer. In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
Page 3
Contents List EHT10 - Turbofan Humidified Holding Cabinet - 10 Tray Half Size. Safety Information EHT10 - Humidified Holding Cabinet Installation Requirements Unpacking Fitting Stand-Off Brackets Water Connection Electrical Connection Positioning the Humidified Holding Cabinet Clearances Commissioning the Humidified Holding Cabinet Using the Humidified Holding Cabinet 1.
Page 4
Contents List 7. Manager Screen #5 Changing Passcodes - Settings Auto-Start Options - Settings System - Displays System Info 8. Manager Screen #6 Controller Time Settings Controller Date / Day Settings Controller Language Selection - (Not Used for this Application) Temperature Units - °F / °C Setting Manager Mode Parameters and Settings - Reference Table Holding Cabinet - General Troubleshooting...
Page 5
Introduction Before using your new Humidified Holding Cabinet, please read this This manual must be kept by the owner for future reference. instruction manual carefully, pay particular attention to any Date of Purchase, Date of Installation A record of the information labelled ‘WARNING’, ‘CAUTION’, ‘IMPORTANT’...
Page 6
Specifications 208V, 60HZ, Single Phase, L1+L2+GND, 2.25kW, 10.8A. USA / Canada 220-240V, 60HZ, Single Phase, L1+L2+GND, 2.25kW, 9.7A. 220-240V, 60HZ, Single Phase, L1+N+E, 2.25kW, 9.7A. All Other Markets 220-240V, 50HZ, Single Phase, L1+N+E, 2.25kW, 9.4A. 10 x 1/1 GN / 20” x 12”, Steam Pan Capacity. 10 x Half Size Sheet Pan Capacity.
Page 7
Installation Installation shall comply with local electrical, health and safety requirements. It is most important that this Humidified Holding Cabinet is installed correctly and that the operation is correct before use. If you have any questions regarding the proper installation and / or operation of this Humidified Holding Cabinet, please contact your local Turbofan distributor.
Page 8
Installation The Oven / Proofer is fitted with a water filtration system. This sys- tem will require the Filter Cartridge and the Double Check Valve connecting to the Filter Body. And the filter system connecting to the mains water supply, Follow the instructions below to connect up the water filter system.
Page 9
Operation - Using the Holding Cabinet Press key to turn control ON. Press , display will return to the ‘Start’ screen shown below. Displays Set Temperature of Cabinet. Pre-Heating w ill occur autom atically. Pre-Heating stage will complete when both the pre-heat Displays Actual Temperature of Cabinet.
Page 10
Operation - Using the Holding Cabinet Displays Set Temperature and Set Water Temperature of Cabinet. Pressing Cabinet or Water temperature will When pre-heating is complete Humidified Holding Cabinet show Actual temperatures for 3 seconds. is ready to use. Load trays into Hum idified Holding Cabinet onto the shelf selected and close the cabinet door.
Page 11
Operation - Using the Holding Cabinet When a product falls below a pre-set time (refer to ‘Manager Mode’ - ‘Hold Programming - ‘LAST SHELF’ time settings), while the number of remaining shelves of that product is lower than the set number, the ‘LAST SHELF’...
Page 12
Operation - Using the Holding Cabinet HELF PTION NOTE: This cabinet can be used with ‘Half Tray Shelf’ or ‘Full Tray Shelf’ settings. This allows two separate recipes to be run on the same shelf, each with a separate timer. For a description on how to set-up and use the ‘Half Tray Shelf’...
Page 13
Operation - End of Shift Cooldown At the end of shift when the Humidified Holding Cabinet is no longer required for use, the cabinet can be cooled down for cleaning etc. By selecting the Cool Down symbol on the main display, the ‘Cool Down’...
Page 15
Manager Mode - Holding Cabinet Settings / Programming Select MANAGER. ENTER Passcode (4500). Press to confirm. Press to cancel. Press to exit ‘Manager’ screen and return to ‘Main’ screen. Press for next MANAGER screen. ROGRAMMING Press to select the recipe to program.
Page 16
Manager Mode - Holding Cabinet Settings / Programming In the ‘Edit Hold’ screen, select the Product Name and Press to step to previous screen. change the name on the keypad displayed. Select the ‘Image’ and change the image for an image shown in the ‘Image Gallery’.
Page 17
Manager Mode - Holding Cabinet Settings / Programming ETTING EMPERATURE On the Hold Settings screen, select set the hold temperature on the keypad displayed. Hold Temperature Range = 60 - 90°C 140 - 194°F Press to confirm changes. Press to cancel changes. ETTING ATER UMIDITY...
Page 18
Manager Mode - Holding Cabinet Settings / Programming Press to exit ‘Manager’ screen and IMERS return to ‘Main’ screen. On ‘Manager Screen 1’, press to copy hold timer information to a USB. Enter Recipe Set Name on keypad. Press to confirm changes. Press to cancel changes.
Page 19
Manager Mode - Holding Cabinet Settings / Programming Press to exit ‘Manager’ screen and return to ‘Main’ screen. IEZO OLUME Press to adjust P iezo volume Up / Dow n. Press for next / previous MANAGER screen. EEPER PTIONS Press to turn TI M E’S UP beep On / Off. Press to turn P R EHEAT R EADY beep On / Off.
Page 20
Manager Mode - Holding Cabinet Settings / Programming Press to exit ‘Manager’ screen and return to ‘Main’ screen. Press to Enable / Disable M ANAGER P asscode. Press to adjust screen BR I GHTN ESS settings. Press to enter AUTO DI M SETTI N GS. Press for next / previous MANAGER screens.
Page 21
Manager Mode - Holding Cabinet Settings / Programming Press to exit ‘Manager’ screen and return to ‘Main’ screen. HANGE ASSCODE CREEN Press to change passcode. N um eric key pad will display. The ‘Change Passcode - Manager’ screen will appear. Press for next / previous MANAGER screen.
Page 22
Manager Mode - Holding Cabinet Settings / Programming Press to exit ‘Manager’ screen and return to ‘Main’ screen. Press to enter / change real time settings. Press to change from AM to PM. Press to enter / change real date settings. Press to enter Language selection (if available).
Page 23
Manager Mode - Settings To enter MANAGER menus, the Default Passcode is ‘4500’. ANAGER ARAMETER ESCRIPTION ANGE EFAULT Manager Screen 1 Select Hold Programming to change the following options :- - Product Name. - Product Image. ---- ---- - Recipe Category. - Recipe Colour.
Page 24
Manager Mode - Settings ANAGER ARAMETER ESCRIPTION ANGE EFAULT Manager Screen 4 Press to Enable / Disable Manager Passcode Protection. Enable / Disable Enable ASSCODE Screen brightness can be adjusted in increments. 1 - 5 RIGHTNESS ETTINGS Time after which display will reduce in brightness by value shown below. 1 - 30 minutes 10 mins ETTING...
Page 25
Troubleshooting Guide This section provides a reference to the more common problems You may encounter a problem not covered in this section, please that may occur during the operation of your Humidified Holding contact your service provider who will require the following Cabinet.
Page 26
Troubleshooting Guide Error Message Probable Cause Corrective Action (Control Screen) Controller internal communication error. ERROR 1 A1. Reboot controller by turning mains power ‘Off’ A. Controller fault. I/O Feedback for at least 10 seconds, then back ‘On’. Call For Service A2.
Page 28
Replacement Parts List Only genuine authorized replacement parts should be used for the servicing and repair of this Humidified Staging Cabinet cabinet. The instructions supplied with the parts should be followed when replacing components. For further information and servicing instructions, contact your nearest authorized service provider or Turbofan Dealer. When ordering replacement parts, please quote the part number and the description as listed below.
Page 29
Appendix 1 - Updating Controller Software To controller software can be updated by Power Off/On The controller software can be installed by USB through Method. Refer below Steps 1-5 for this procedure. the Service Mode if the existing software shows the option ‘UPDATE SOFTWARE’...
Page 30
Appendix 1 - Updating Controller Software To verify a software update or to check a software The SOFTWARE NUMBER shown in the SYSTEM screen below version, follow Step 1 to Step 4 as shown below. shows the Software number and version that is operating on the controller.
Page 31
Appendix 2 - Humidified Holding Cabinet Door Reversal NOTE: CABINET BODY. Refit all screw fasteners using a low-mid strength Remove four blanking screws covering alternate hinge holes thread locking adhesive unless otherwise stated. on RH side of cabinet. Refit cover screws on opposite side. Remove Top Hinge Bracket and Packer Plate from upper LH ...
Page 32
Appendix 2 - Humidified Holding Cabinet Door Reversal To Check / Adjust Door Alignment: Check alignment and operation of the door. Ensure that the door There should be a is correctly aligned horizontally and vertically. nominal gap of 6mm from edge of door to side of control panel.
Need help?