DIRECT VENT GAS-FIRED FIREPLACE INSERT
WARNING!
If the information in this manual is not fol-
lowed exactly, a fire or explosion may result
causing property damage, personal injury or
loss of life.
-Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
-WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
If you cannot reach your gas supplier, call the fire
department.
-Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
WARNING!
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information, consult
a qualified installer, service agency or the
gas supplier.
The appliance area must be kept clear and free from combustible materials,
Aladdin Hearth Products
401 N. Wynne
Colville, WA 99114
A Division of Hearth Technologies Inc.
AFFINITY 25
ROOM HEATER
MODEL: DVi25S
OWNER'S MANUAL
AND INSTALLATION INSTRUCTIONS
FOR YOUR SAFETY
gasoline and other flammable vapors and liquids.
®
This manual must be used for installation of the DVi25S
Direct Vent Gas Fired Fireplace Insert Room Heater and
retained by the homeowner for operating and maintenance
instructions.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DVi25S and is the answer not in the manual?

Questions and answers

Summary of Contents for Arrow DVi25S

  • Page 1 -Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING! This manual must be used for installation of the DVi25S Improper installation, adjustment, alteration, Direct Vent Gas Fired Fireplace Insert Room Heater and...
  • Page 2: Table Of Contents

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater Table of Contents Listings and Code Approvals........................3 Description of the DVi25S System ......................3 III. Appliance System Components ......................4 Pre-Installation Preparation ........................5 A. Vent System Approvals ......................5 B.
  • Page 3: Listings And Code Approvals

    WITH AIR FILTER. - NE PAS UTILISER DE FILTRE A AIR AVEC CE FOYER AU GAZ A EVACUATION. II. DESCRIPTION OF THE APPLIANCE SYSTEM The DVi25S is a Direct Vent Gas-Fired Fireplace Insert Room Heater. Combustion air is supplied from outside, not from inside the house as with other types of appliances.
  • Page 4: Appliance System Components

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater III. APPLIANCE SYSTEM COMPONENTS Catalog Number Description DVi25S Direct Vent Gas Fired Insert - Natural Gas with-out Front Face DVi25SL Direct Vent Gas Fired Insert - Propane Gas with-out Front Face...
  • Page 5: Pre-Installation Preparation

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater IV. PRE-INSTALLATION PREPARATION WARNING! This appliance may only use the Direct Vent Chimney System Required with the Unit and MUST NOT be connected to a chimney flue servicing a separate Solid Fuel or Gas Burning appliance.
  • Page 6: Clearances

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater E. CLEARANCES TO UNIT Diagram B shows the minimum vertical and corresponding maximum horizontal dimensions of mantels or other com- bustible projections above the gas fireplace of 12 inches. When finishing the fireplace NEVER OBSTRUCT OR MODIFY THE AIR INLET/OUTLET OPENINGS IN ANY MANNER.
  • Page 7: Step-By-Step Installation Of The System

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater V. STEP-BY-STEP INSTALLATION OF THE DVi25S SYSTEM WARNING! BEFORE STARTING, DO THE FOLLOWING: Wear gloves and safety Glasses for protection. Keep hand tools in good condition. Sharpen cutting edges and make sure tool handles are secure.
  • Page 8 ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater Place the insert on the hearth and carefully slide it into the fireplace. Be sure the gas line enters the heater Termination Cap through the gas access opening and that the electrical cord is hanging out the front of the fireplace.
  • Page 9: Gas Line Installation

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater Roof Pitch H (Min.) feet Flat to 6/12 6/12 to 7/12 1.25 Over 7/12 to 8/12 Over 8/12 to 9/12 Over 9/12 to 10/12 Over 10/12 to 11/12 3.25 Over 11/12 to 12/12...
  • Page 10: Surround Installation

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater C. SURROUND INSTALLATION 5. Optional Surround Bottom Remove surround bottom from carton. Place hooks NOTE: Remove the Front Face and Glass Door on the surround bottom through the slots on bottom Assemblies from the Insert before beginning the of the surround side.
  • Page 11: Rock Wool And Lava Rock Placement

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater D. ROCK WOOL AND LAVA ROCK PLACEMENT likely to be stained by the cleaning agent. Stubborn The logs are shipped in place. If you have any ques- film can often be removed using Cook Top Cleaning tions regarding the logs, please contact your local deal- Creme available at appliance centers.
  • Page 12 ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater Figure 2AF Figure 3AF Access Door Catch Access Door Installation of the Bay Front Face. Turn off power to the Insert by shutting off the Circuit Breaker or unplugging the Power Cord.
  • Page 13: Gold Trim Cleaning

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater SLOT Figure 5BF Figure 4BF Figure 6BF Extension Knob Placing Lava Rock Into Bay Placing Bay into Slots Valve Access for the Bay Front Face. The Valve Access Door, located at the base of the Bay Front Face, is opened by lifting up on the Door Handle and then rotating downward.
  • Page 14: Wiring

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater J. WIRING Note: This appliance DOES require a Note: This appliance must be electrically 110-120 VAC supply for operation of the wired and grounded in accordance with Blower. local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition.
  • Page 15 ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater Ignitor Pilot Thermopile Thermocouple Rocker Switch / Wall Thermostat / Remote Push Button Ignitor Pilot Adjustment Variable Regulator Manifold Pressure Inlet Pressure Wiring Diagram B K. PRE-USE CHECK Before operating this appliance, please review the...
  • Page 16: Operating Instructions

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater VI. OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 17 ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater Upon completing the gas line connection, a small CAUTION: The Logs can get very hot. - amount of air will be in the lines. When first lighting the only handle them when they are cool.
  • Page 18: Maintenance Instructions

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater VII. MAINTENANCE INSTRUCTIONS CLEANING THE BURNER AND THE CLEANING THE GLASS: CONTROL COMPARTMENT: Note: Keep the burner and control compartment clean by When cleaning the glass, NEVER using a clean, dry paint brush and vacuum at least use abrasive materials.
  • Page 19: Trouble Shooting

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater VIII. TROUBLE SHOOTING Problem Cause Corrective Action A.Gas control knob 1. Pilot will not Turn knob to PILOT and push in on the valve (see lighting isn’t turned to ignite. instructions on page 16).
  • Page 20: Replacement Parts

    ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater IX. REPLACEMENT PARTS Replacement parts are available from your distributor/dealer, or through ARROW Customer Relations, Aladdin Hearth Products, 401 N.Wynne, Colville, WA 99114. ITEM PART NO. DESCRIPTION 28469 DVi25 Log Assembly...
  • Page 21 ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater REPLACEMENT PARTS CONTINUED ITEM PART# DESCRIPTION ITEM PART# DESCRIPTION 28240 Hearth Plate 30437 Surround Top - 32 28237 Refractory 30438 Surround Top - 38 28225 Burner Assembly 30442 Surround Side (LH) - 32...
  • Page 22 ® DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater REPLACEMENT PARTS CONTINUED RF25 - Rectangular Face Kit ITEM PART # DESCRIPTION 28458 Rectangular Front Face Ass. 28459 Front Face 28233 Front Face Top and Bottom 28234 Decorative Rod - Gold...
  • Page 23 This limited Lifetime Warranty is effective on all Dovre and Arrow stoves sold at point of purchase after July1, 1998, and all Quadra-Fire stoves sold after September 1, 1996, and supersedes any and all warranties currently in existence.
  • Page 24 Attention INSTALLER Please return these Operating & Installation Instructions to the Consumer Aladdin Hearth Products 401 N Wynne Colville, WA 99114 A Division of Hearth Technologies Inc. 11-98 29855 Rev B...