    13-14 Filter Controls 15-20 ALL RIGHTS RESERVED, THIS MANUAL AND THE INFORMATION CONTAINED ARE NOT ALLOWED TO BE USED WITHOUT WRITTEN PERMISSION FROM AUTOMATIC FILTERS INC. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 3: Introduction

    Automatic Filters Inc. are easy to install, use and service and don’t require special skills to operate them We would like to wish you many years of satisfied service. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 4: Description & Operation

    The CSB filter contains the following parts: 1. Inlet 4. Flushing Valve (HYD or Electric) 2. Screen 5. Electric Motor 3. Brush 6. Outlet Figure 1: Filter Assembly For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 5 At the end of the 10 second cycle the flushing valve (4) closes and the operation of the electric motor (5) is stopped. The filter is now ready for the next cycle, Figure 2: Filter Assembly For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 6: Technical Data

    * Flow rate data are for high quality water at filtration grade of 200 micron. ** Flushing flow rate data are for minimum operational pressure (1 bar / 15 psi). Filtration Grade Conversion Table Micron 1500 3000 Mesh For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 7 &6% 0$18$/ Pressure Loss At 200 Micron For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 8: Installation

    6. Check that all connections are properly secured. 7. Check that all bolts and nuts on filter periphery are properly tightened and secured. Figure 3: Initial Filter Installation For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 9 9. Set the appropriate differential pressure for flushing at the ∆P differential pressure indicator to 0.5 bar (7 PSI). WARNING Take precautions while operating the filter because the filter might enter a flushing mode automatically, without prior warning. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 10: Filter Assembly

    Check for leaks. WARNING Take precautions while operating the filter because the filter might enter a flushing mode automatically, without prior warning. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 11 &6% 0$18$/ Figure: 4 Figure: 5 For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 12 &6% 0$18$/ Figure 6: Brush Removal & Installation Figure 7: Fine Screen Assembly Removal & Installation For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 13: Periodic Checks

    4. Check the filter housing for paint damage and corrosion. If required, clean area with sandpaper and apply a thin layer of basic + epoxy paint. 5. Check for leaks. Figure 8: Periodical Checks For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 14 &6% 0$18$/ )LJXUH For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 15: Filter Parts

    2” Flushing Valve Seal Housing Nut Special Rope Seal Seal Tightening Nut Motor Adaptor Spinning Shaft Shaft Splint Electric Motor 300A Terminal connections Assembly 300B Brushes Assembly For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 16: Filter Controls

    For other phase supply voltage TR1 must be wired accordingly : 380 V -------------------------------- TR1 tags No. 1 & 2 415 - 420 V ------------------------- TR1 tags No. 1 & 3 For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 17 TD – Interval flush timer. (Factory set to 10 hours & enabled - TB 13/14 shorted) NOTE that the TD timer can be disabled by removing the short wire from TB 13/14-SET inlets) For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 18 On elapsed set time the timer will activates the internal relay. Resetting the timer done by disconnecting the supply voltage. Range and time setting. Range set knob Time set knob 1------2------3------4------5------6------7------8------9------10 For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 19 No light = The timer is in off state. (No supply on A1/A2 terminals) b. Blinking light = The timer is counting/On delay. c. Steady light = The timer reached the time set. (Internal relay energized) For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 20 &6% 0$18$/ For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 21 &6% 0$18$/ For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 22 THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, EXCEPT THIS WARRANTY WHICH IS GIVEN IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...

This manual is also suitable for:

Csb 4Csb 6Csb 8Csb 10Csb 12Csb 14 ... Show all