» Caution for handling the LCD panel
1. Work in a clean room. (Humidity: 50% or more)
2. A worker must wear arm bands.
3. Work on a conductive mat.
4. Do not expose the unit to shock such as fall or vibration.
Diffusion Sheet
ITO Sheet
Condenser Sheet
LCD Display Unit
1
Reflection Panel
Light Guide Plate
Reflection Sheet
6
8
Reflection Polarizing Sheet
<<Disassembly of LCD Panel>>
1. Remove the six LCD unit fixing screws.
2. Remove the shield case.
3. Remove the light guide panel holder.
4. Remove the reflection panel.
5. Remove the lamp unit.
6. Remove the light guide plate.
7. Remove the fixing angle.
8. Remove the ITO sheet, diffusion sheet and the
reflection polarizing sheet.
2
3
5
4
7
Lamp Unit
Fixing Angle
(KLMP-0098CEZZ)
7
LC-15A2M
Shield Case
1
Light Guide Plate Holder

Advertisement