Manual for dialog Web Order no.: 443 150 Technical Manual dialog Web Version 2.01 Radevormwald, 01.09.2020 Version 2.01 Page 1 / 47 01.09.2020...
Manual for dialog Web Order no.: 443 150 Content Introduction..............4 1.1. Using the manual..............4 1.2. Support...................5 1.3. Warranty and liability............5 1.4. Explanation of used pictograms..........5 1.5. Safety instructions..............6 1.6. Order information..............6 Product description............7 2.1. Applications................7 2.2. Functionality................9 2.3. Licensing.................9 2.4.
Page 3
Manual for dialog Web Order no.: 443 150 4.3.1 Web room control unit object........27 Glossary.................44 Version 2.01 Page 3 / 47 01.09.2020...
Order no.: 443 150 1. Introduction Thank you for choosing a spega product. This product has been designed and optimized for use in room automation. To familiarize yourself with the handling and functionality of the system, we would ask you to read this manual carefully. It contains information about the operation, assembly and parameterization of the system.
Electrical devices must be assembled and installed by trained personnel only. Operation of the device is determined by the application software. Only software which has been approved by spega should be used for this device. The system integrator should ensure that the software and relevant parameterization correspond with the wiring and intended use of the device.
Manual for dialog Web Order no.: 443 150 2. Product description The dialog Web Server is the basis for all room automation control functionalities by using standard web-browser or IP-capable telephones (optional) for up to 150 rooms. For installations with more than 150 rooms respectively more dialog Web Server are needed.
Page 8
Manual for dialog Web Order no.: 443 150 Room control via web browser on mobile devices. Version 2.01 Page 8 / 47 01.09.2020...
Each additional web-license enables the operation of another Lonmark object and thus another room. The activation of the operation of the Lonmark objects happens per dialog Web Server in the following order. For example, if you have 50 web licenses, the first 50 Lonmark objects can be operated via web browser.
Page 10
Manual for dialog Web Order no.: 443 150 (rooms). Thus, it can be defined which rooms can only be operated via web browser and which additionally via IP telephone. Version 2.01 Page 10 / 47 01.09.2020...
Manual for dialog Web Order no.: 443 150 2.4. Technical Data Supply Power supply 12 or 24 V DC Current input Max. 15 W Network Type of network Ethernet (100/1000 Base-T) Connections Supply 3-pin connector with screw clamp terminal Network...
Page 12
Manual for dialog Web Order no.: 443 150 Standards / guidelines Certification Version 2.01 Page 12 / 47 01.09.2020...
Electrical devices must be assembled and installed by trained personnel only. The dialog Web Server can either be mounted on the supplied mounting plate for mounting on a top-hat rail (DIN EN 50022), or it can be glued with the supplied rubber feet and operated as a desktop device.
Manual for dialog Web Order no.: 443 150 3. Configuration 3.1. IP configuration The IP configuration can only be changed via the web interface. The correct display and operability is only given for the web browsers Mozilla Firefox (version 3.6 or higher) and Safari (version 4 or higher).
Page 15
Manual for dialog Web Order no.: 443 150 Click on Device Configuration and in the following page on LAN. Here you can now carry out the IP configuration. Three different operating modes are available. 1. The device is only operated with an Ethernet interface (LAN A). Access to the web server (HTTP) and the EIA-852 part (LON over IP) is via an IP address.
Page 16
Here you can specify the EIA-852 configuration server and the ports to be used. The default ports 1628 and 1629 for the Lon-over-IP protocol are preset. Please note that the dialog Web Server must be made known to the configuration server.
The Lonmark objects are configured using LNS plug-ins. They offer the possibility to transfer all settings to a selection of Lonmark objects of all dialog Web Servers that are located in an LNS project. This function can be found in the plug-ins in the File menu and is called Transfer parameter.
Manual for dialog Web Order no.: 443 150 The several operating modules are assigned to the several elements of a Lonmark object on the configure room operating units (RBG) page. You can create several user interfaces (RBG variants) here. One for each LON configuration (room type). As a help, you can display the LON configuration of any Lonmark object (room) as a room reference in this dialog.
The user Administrator has the password dialogweb by default. He is the only user who has access to the configuration of the dialog web server. The password should be changed to prevent unauthorized access. The user name cannot be changed.
Manual for dialog Web Order no.: 443 150 Note: The password for the user Administrator as well as the license are not saved and are not changed when the configuration is restored. 3.8. Firmware update Before updating the firmware, you should first make a backup of the configuration and save the license as a file.
Manual for dialog Web Order no.: 443 150 4. Applications This document describes the behaviour and parametrisation of the applications listed below. The applications are split into logical objects according to LonMarkTM- Interoperability-Guidelines. The objects' behaviour is described separately in this document.
Manual for dialog Web Order no.: 443 150 4.3. Description of software objects The individual functional objects are described in greater detail below. 4.3.1 NodeObject Interface description Network interface Version dialog Web Status 01.03.10 UFPTnodeObject UFPT #0 nviRequest nvoStatus SNVT_obj_request...
Page 24
Manual for dialog Web Order no.: 443 150 nviConfig communication nviFileReq specifies the requested interface for plug-ins file operation and the file index Type: UNVT_config Type: SNVT_file_pos Receiving not available inspection: Receiving not available inspection: Output variables nvoStatus output for status...
Page 25
Manual for dialog Web Order no.: 443 150 SCPTlocation extended description UCPTalarmDesc Field with 16 alarm [16] of the position of the descriptions that can device be sent out in case of device alarms Type: SCPT #17 SNVT_str_asc Type: UCPT #4...
Page 26
Manual for dialog Web Order no.: 443 150 Status request The status of the device and individual objects can be requested via the network variable nviRequest. The response to the request can be taken from the network variable nvoStatus. The following commands are to be used for...
Page 27
Manual for dialog Web Order no.: 443 150 4.3.1 Web room control unit object The UFPTwebOperationPanel object represents a room control unit with separately configurable functional components. Interface description Version Status 01.03.10 Network interface UFPTwebOperationPanel UFPT #23203 Switch (8x) nviValueFb...
Page 28
Manual for dialog Web Order no.: 443 150 Function description The UFPTwebOperationPanel consists of several independent functional components. In addition to 8 individually usable push-button objects, it also contains room climate control and scene control. Functional component - touch sensor The push-button object is based on the function profile UFPT_Switch.
Page 29
Manual for dialog Web Order no.: 443 150 Interface components Network variables nviValueFb feedback input for nvoValue light control: switching/dimming output of the switching actuators when using values (switching/dimming) several pushbuttons for sun protection control: one light circuit output of movement...
Page 30
Manual for dialog Web Order no.: 443 150 Parametrierung des Funktionsobjektes UCPTswitch operating module type UCPTenable specifies whether the Auto sending of "invalid" Type: enumerated values (undoing an (UCPT #97) override) is permitted Value range: -1 SU_NUL (invalid) Type: boolean...
Page 31
Manual for dialog Web Order no.: 443 150 UCPTsource for future use UCPTbutton action that is executed when Info Event[6] the respective button is Type: enumerated clicked (UCPT #6) Type: enumerated (per entry) Value range: function dependent (UCPT #102) Preallocation:...
Page 32
Manual for dialog Web Order no.: 443 150 Basic parameterization Operating module type In the parameter UCPTswitchUse the type of the operating module to which the push-button function component is assigned must be specified. Network variable types The push-button function component supports the network variable types SNVT_switch (only for light operation) and SNVT_setting.
Page 33
Manual for dialog Web Order no.: 443 150 Function Value on nvoValue DIM_UP "dim up" SNVTswitch = (letzter Wert+S*, 1) The object sends a dimming value incremented by S (SCTPstepValue). The SNVTsetting = (SET_UP, S*, 0) dimming process is limited by SCPTMaxOut.
Page 34
Manual for dialog Web Order no.: 443 150 Functional components - Room climate control function component room climate control based SFPTsccCommandModule function profile. It defines the function of the "Energy level", "Room temperature" and "Fan control" control modules. Interface components...
Page 35
Manual for dialog Web Order no.: 443 150 Network variables Network input variables nviEffectOcc input for current energy nviEnergyHld input for locking the level of the individual room heating/cooling function controller or the room (e.g. when opening occupancy status windows)
Page 36
Manual for dialog Web Order no.: 443 150 nviUnitStatus input for current controller nviSetpt input for local setpoint OffsetFb output values and shift controller function Type: SNVT_temp_p Type: SNVT_hvac_status Value range: -10.00 ... + 10.00 °C Structure: .mode Preallocation: 0.00°C (0)
Page 37
Manual for dialog Web Order no.: 443 150 Network output variables nvoOccupancy specification of the energy nvoFanSpeed input for local setpoint shift level/room occupancy Type: SNVT_switch status for individual room Value range: depending on controller UCPTfanLevels Type: SNVT_occupancy .value with:...
Page 38
Manual for dialog Web Order no.: 443 150 UCPTfanLevels number of adjustable fan UCPTfreshAir value to be sent on request CmdOn speeds of the controller for supply air Type: unsigned Type: SNVT_lev_cont (UCPT #92) (UCPT #18) Value range: 1 ... 3 stages Value range: 0.0 % ...
Page 39
Manual for dialog Web Order no.: 443 150 Basic parameterization Area code The parameter UCPToperatingLocation is used to enter a plain text for assignment to a room or an operating area. The value is displayed in the web configuration interface.
Page 40
Manual for dialog Web Order no.: 443 150 Value Function used interface components controller activity registration and nviUnitStatus.heat_output_primary, display nviUnitStatus.cool_output, nviSccSync.heat_output, nviSccSync.cool_output controller function registration and nviSccSync.heat_cool display Parameterization: registration UCPTenableHvacMode, UCPThvacMode Output: nvoSccSync.heat_cool Heating/cooling registration nviEnergyHldOff, nviUnitStatus.in_alarm.bit2, interruption nviSccSync.in_alarm.bit2 nviUnitStatus.in_alarm.bit1,...
Page 41
Manual for dialog Web Order no.: 443 150 The resulting setpoint shift is sent after each change to nvoSetpointOffset and nvoSccSync.setpoint_offset. Controller activity Using values received nviUnitStatus (.heat_out_primary and .cool_output) or nviSccSync (.heat_output and .cool_output), the controller activity (heating/cooling) can be determined and displayed.
Page 42
Manual for dialog Web Order no.: 443 150 Presence If the buttons of the operating module are not used to switch the energy level and manual logon and logoff is enabled in the parameter UCPTenableOcc, the logon or logoff telegram specified in UCPToccCmds is sent on the nvoOccupancy when the corresponding button is selected.
Page 43
Manual for dialog Web Order no.: 443 150 Function component - Scene control The scene control function component is based on the UFPTscenePanel function profile. It defines the function of the "Scene control" operating module. Interface components UFPTwebOperationPanel UFPT #23203...
Page 44
Manual for dialog Web Order no.: 443 150 Configuration parameter UCPTscButton maximum number of UCPTscButton configuration of the scene Count Config[16] scene buttons (constant) buttons (scene number and learning support) Value: Type: structure (UCPT #45) UCPTscDesc description of each scene Value range: .scene_nmbr :...
Page 45
Manual for dialog Web Order no.: 443 150 5. Glossary alternating current Alias entry address entry for a member of a group binding in the sending node amplitude shift keying Bluetooth industry standard for wireless radio networking over short distances fire damper ‚Communauté...
Page 46
Manual for dialog Web Order no.: 443 150 Short address individual address for identification of DALI devices light emitting diode LonWorks network services LON™ local operating network LonMark™ international organization with the intention to advance and bring forward the LON technology LonWorks™...
Page 47
Manual for dialog Web Order no.: 443 150 Transmitter ID individual, unique 32-bit transmitter identification for wireless transmitters, based on EnOcean technology UCPT user configuration property type UNVT user network variable type ‚VDE Verband der Elektrotechnik, Elektronik und Informationstechnik e.V.‘...