Marshall Amplification DH5-4444DMK Owner's Manual

Marshall Amplification DH5-4444DMK Owner's Manual

Heated holding unit

Advertisement

Quick Links

OWNER'S MANUAL
MODEL DH5-4444DMK – HEATED HOLDING UNIT
DH5-4444DMK
PRODUCT DESCRIPTION
This Heated Holding Unit features Marshall's own
ThermoGlo heating technology. Heat radiates from
every square inch of the upper and lower flat plate
heating surfaces. This eliminates the need to clean
intricate calrod, wire and reflector assemblies.
The
DH5-4444DMK
accommodates up to three 1/3 size pans 2 1/2" deep,
two 1/2 sheet pans, one full pan or one 1/2 sheet pan
per deck.
The unit is controlled by four independent integrated
time/temperature controllers located on the front of the
heated holding cabinet. The controls determine the
intensity of top and bottom heaters. The integrated
time/temperature controllers also feature 3 independent
countdown timers to help maintain product integrity. An
On/Off switch for each deck is easily accessible to the
store personnel allowing them to turn ON and OFF any
desired deck. The Heated Holding Unit offers the latest
in technological design which gives you the most
favorable holding characteristics in a system that is
simple to work with and operate.
165037 RV113018
Copyright © 2014 Marshall Air Systems, Inc.
All Rights Reserved.
Heated
Holding
Units
Supplier Name:
MARSHALL AIR SYSTEMS, INC.
Address:
419 Peachtree Drive South
Charlotte, NC 28217
Model #'s:
_____________________________
Serial #'s:
_____________________________
Date Received:
_____________________________
Date Installed:
_____________________________
Telephone #:
704.525.6230
Fax #:
704.525.6229
Service Referral #: 800.722.3474
Local Service Name:____________________________
Local Service #:
____________________________
GENERAL SPECIFICATIONS
Model:
DH5-4444DMK
Height:
30.125"
Width:
22.375"
Depth:
14.500"
Electrical:
380/220V
3PH WYE - L1: 2.9A, L2: 2.9A, L3: 3.9A,
N: 3.9A
1PH W/ Neutral – L1: 4.8A, L2: 4.8A,
N: 4.8A
Weight:
85 lbs
Approvals:
NSF, ETL/CETL and CE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DH5-4444DMK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Marshall Amplification DH5-4444DMK

  • Page 1 OWNER’S MANUAL MODEL DH5-4444DMK – HEATED HOLDING UNIT Supplier Name: MARSHALL AIR SYSTEMS, INC. Address: 419 Peachtree Drive South Charlotte, NC 28217 Model #’s: _____________________________ Serial #’s: _____________________________ Date Received: _____________________________ Date Installed: _____________________________ Telephone #: 704.525.6230 Fax #: 704.525.6229 Service Referral #: 800.722.3474...
  • Page 2 OWNER’S MANUAL MODEL DH5-4444DMK – HEATED HOLDING UNIT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE AVERTISSEMENT Ne pas entreposer ni utiliser de l’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil, ni de tout autre appareil.
  • Page 3: Table Of Contents

    TIME / TEMPERATURE ADJUSTMENT PROCEDURE ..........FIGURE 3 SCHEMATICS WIRING SCHEMATIC, DH5-4444DMK 380/220V 3 PH WYE ......... #165042 WIRING SCHEMATIC, DH5-4444DMK 380/220V 1 PH W/ NEUTRAL ......#177758 165037 RV113018 Copyright © 2014 Marshall Air Systems, Inc. All Rights Reserved.
  • Page 5: Pre Installation

    OWNER’S MANUAL MODEL DH5-4444DMK – HEATED HOLDING UNIT PRE-INSTALLATION 1. The Heated Holding Unit is packaged to minimize the risk of shipping damage. Immediately upon receipt, make certain to inspect the unit for damage. FILE ALL CLAIMS WITH THE FREIGHT CARRIER.
  • Page 6: Timer/Temperature Controller Operation

    OWNER’S MANUAL MODEL DH5-4444DMK – HEATED HOLDING UNIT TIMER/TEMPERATURE CONTROLLER OPERATION The following is the user interface layout: Up & Down Arrow Middle Pan Display Right Pan Display Left Pan Display Buttons Left Pan Middle Pan Right Pan Temperature Button...
  • Page 7: Daily Maintenance

    OWNER’S MANUAL MODEL DH5-4444DMK – HEATED HOLDING UNIT DAILY MAINTENANCE 1. Turn off the unit and allow it to cool for 20 minutes. 2. Pans and/or pan covers should be removed, washed in mild multi-purpose detergent, rinsed and sanitized. 3. Clean unit and base with a damp cloth/rag and a mild cleaner.
  • Page 8: Troubleshooting

    OWNER’S MANUAL MODEL DH5-4444DMK – HEATED HOLDING UNIT TROUBLESHOOTING CHART Before trouble shooting is started: check unit is plugged in, check for tripped circuit breaker and check that power switch on. ** DISASSEMBLING HEATER VOIDS WARRANTY ** PROBLEM POSSIBLE CAUSE SOLUTION 1.
  • Page 9: Replacement Parts

    OWNER’S MANUAL MODEL DH5-4444DMK – HEATED HOLDING UNIT REPLACEMENT PARTS QTY PER PART # DESCRIPTION UNIT FIGURE 504342 Blanket, Bottom Heater 2, Schematic 504343 Blanket, Top Heater 2, Schematic 160637 Control, Integrated Time/Temp 2, Schematic 503598 Cord Set, 18/5 (DH5-4444DMK 3PH)

Table of Contents