Outlet Filter user manual JNPH1AF JNPH2AF JNPH3AF...
Page 2
The copyright belong to Supplier. This document involves the proprietary and confidential information about High voltage solar charger of Supplier. It strictly prohibited to disclose the document by duplicating, photocopying, publishing online and in other forms without Supplier’s permission. Supplier. reserves the right to change details in this publication without notice. V1.0...
For JNP22KH/ JNP30KH/ JNP37KH/ JNP45KH/ JNP55KH solar pumping system. In order to describe conveniently later, there is no distinguish between JNPH1AF, JNPH2AF, JNPH3AF, They will be short for JNPH x AF. Target Reader This manual applies to the professional engineering and technical person who is responsible for installing and operating of outlet filter.
Page 4
Means that the content is additional information. Noted Outlet Filter related symbols: Symbol Meaning AC power Refer to relevant instructions Cannot discard Power Pack together with domestic garbage. Beware of dangerous high-voltage. Should wait for 5 minutes after outlet filter and AC power are disconnected, then Power Pack only can be touched.
1 Outlet Filter Unpacking 1.1Accessories Unpacking Supplier. Supplies standard outlet filter and common accessories as following: Figure1-1 Outlet filter and standard accessories Table1-1 Outlet Filter and Accessories Table Introduction Delivery State Outlet Filter Standard Fixing Rail Standard Expansion Bolt Standard Cool pressure terminal Standard Packing List...
Figure1-2 Outlet filter dimension figure Table1-1 Outlet Filter Dimension Model Width (mm) Height (mm) Depth(mm) Net weight JNPH1AF 14.5 JNPH2AF 17.5 JNPH3AF 1.3 Identify Filter The nameplate in the side of filter, and it shows the filter model, some important parameter and certificate mark.
2 Installation Procedure 2.1 Installation Tool The installation of AC filter and wire should use tools as follow ing, user can select proper tools according to experience. Table2-1 Installation tool list schematic Name Specification Function Crimping Pliers connecting wire’s processing Electric Drilling Ф8 For hole drilling...
100cm 100cm 100cm Fig. 2-2 Outlet Filter min. spatial size figure As figure2-2 show outlet filter shall be installed on right side of inverter. Please do keep the distance between inverter and outlet filter over 100cm. Table2-2 Min. spatial size marking Location Min.
Page 10
Step2: Drilling hole in selected site according to the size and shap e of board, It is recommend that the hole diameter should 10+1/-0 and depth is 60+5/-0. 230mm expansion bolt to fixed board on the wall. Fig. 2-4 JNPHxAF Mounting hole location Step3: Let expansion bolt in hole, hange the lugs on expansion bolt as fig.
3 Electrical Connection 3.1Outlet filter system installation and connection The outlet filter connected between inverter and water pump. System optimization for long cable reflect in the following 3 points: (1) Effective control of motor reflected voltage, protect motor insulation, prolong the lifespan of pump; (2) Effective suppress the surge voltage on the electric cable, protect inverter power module;...
Page 12
U V W A B C Fig.3-2 Bottom view of outlet filter Fig.3-3 Internal Terminal Close the bottom cover plate and lock catch when finish wire connection. And the bottom over plate in an open condition is strictly prohibited. Then the outlet filter connection has been completed.
4 Usual malfunctions and maintenance Solutions to typical faults and states. Table4-1 Running exception handler table Situation Possible Reason Solution Display output phase Outlet filter wiring Turn off inverter and open filter’s failure when inverter get loose. cover plate check wiring running.