Chapter 2 Specific Informations; Setting & Adjusting Data - Toshiba 20N7XE Service Manual

S9s chassis
Table of Contents

Advertisement

CHAPTER 2
SPECIFIC INFORMATIONS
SAFETY INSTRUCTIONS
SERVICE MODE
ADJUSTING ITEMS AND DATA IN THE SERVICE MODE:
Item
Name of adjustment
RCUT
R CUTOFF
GCUT
G CUTOFF
BCUT
B CUTOFF
GDRV
G DRIVE
BDRV
B DRIVE
SCNT
SUB-CONTRAST
BRTC
SUB-BRIGHT
COLC
SUB-COLOUR NTSC
COLP
SUB COLOUR PAL
COLS
SUB COLOUR SECAM
BELL
BELL FILTER
DESIGN MODE
ADJUSTING ITEMS AND DATA IN THE DESIGN MODE:
Item
* There are no adjustment mode in the DESIGN MODE.
SETTING & ADJUSTING DATA
HIGH VOLTAGE AT ZERO BEAM:
MAX HIGH VOLTAGE:
AC VOLTAGE:
Preset
Data
20H
20H
20H
80H
80H
07H
80H
80H
F6H
F6H
01H
Name of adjustment
20"
24.6kV
(A)
26.0 kV
(B)
110~240V
(C)
Table-1
Item
Name of adjustment
SBY
SECAM B-Y
SRY
SECAM R-Y
TNTC
SUB-TINT
HPOS
HORIZ. POSITION
VPOS
VERT. POSITION
HIT
HEIGHT
VLIN
V-LINEARITY
WID
PICTURE WIDTH
PARA
E-W PARABOLA (DPC)
CNR
E-W CORNER
TRAP
TRAPEZIUM
Table-2
Preset Data
Data
Table-3
– 18 –
Preset
Data
08H
08H
40H
0AH
03H
30H
20H
0CH
0DH
28H
1FH
08H
09H
10H
Remarks

Advertisement

Table of Contents
loading

Table of Contents