Status menu…..............4 Settings menu……............... 7 HYDRAULIC CONNECTION…............8 pH probe installation……........... 8 Injector installation……............8 Installation diagram………..........9 ELECTRICAL CONNECTION…............. 10 Caution : Read these instructions carefully before installing, starting up or using this appliance. CCEI page 1...
If it is to be used with another type of solution, please check the compatibility of the equipment with the manufacturer. Its use with hydrochloric acid at more than 10% solution is not recommended. When the device is metering doses, the pump does not run continuously but for about 1 minute in 2. CCEI page 3...
Awaiting the next 24-hour period Tank empty The tank is empty. Awaiting refill . Err. pH The pH is abnormal (>9.9 or <3.9). Check the probe, calibrate once again the probe, check the buffer solutions. CCEI page 4...
Page 5
ATTENTION If this value is left at 0 litre, there would be no limit on the volume injected per day. Therefore, it would be wise to set a value for this parameter. CCEI page 5...
Page 6
If the calibration has been successfully completed, the message Calibration pH appears on the display. However should the Err. ! message appear, the calibration should be repeated after checking the solutions and the condition of the probe. If the problem remains, contact your dealer. CCEI page 6...
This screen is used to reinitialise and reset to 0 the various PHILE0 meters. The hour meter, the total quantity of injected liquid are reset to 0. RESET overrides previous calibrations. In installer mode the total injected volume since the first operation (or last reset) is displayed. CCEI page 7...
The probe is designed for measuring and checking pool pH by sending information to the electrical box. pH probe Ph probe screw Adapter for fitting the probe on the pipe. Use TEFLON to screw this part in the clamp saddle. Clamp saddle to be fitted onto the pipe CCEI page 8...
To this end, a 63 or 50 mm tightening band is used. If a heater and an electrolytic cell are used, they should be placed between the pH probe and the injector (acid or alkaline solution), as shown in the diagram below. CCEI page 9...
Dry contact means potential free and should be used only for one device. If a CCEI filtration box is being used, this dry contact can be taken from terminals 7 and 8 (for GC type contactors) and terminals 13 and 14 (for LC1 type contactors) if these terminals have not already been used.
Page 12
Date of sale : ............... Serial number :..................Declaration The company Bleu Electrique (FR 47403521693) declares that the PHILEO product satisfies the safety and electromagnetic compatibility requirements specified in European directives 2006/95/CE and 2004/108/CEE. Emmanuel Baret Marseilles, 11/04/2016 Distributor’s stamp CCEI page 12...