  • Page 1 Installation Guide EG-2 Ethernet Gateway...
  • Page 2 Contents Introduction Basic Schematic Installation Product Overview Connecting the Supply iCAN Network Connections Set Up Instructions Configuration Setting the IP address Cooper Lighting Solutions EG-2 9850-000776-01...
  • Page 3 Dimensions this then enables remote connection for programming & obtaining diagnostics of the lighting control system. The built in astronomical timeclock feature enables preprogrammed timed events for your lighting system. Cooper Lighting Solutions EG-2 9850-000776-01...
  • Page 4 IDENT CAN Termination Switch that causes the EG2 to End of network send a message on the CAN termination jumper. BUS to identify itself iCAN status Green flashing LED indicates normal operation Cooper Lighting Solutions EG-2 9850-000776-01...
  • Page 5 T - Indicates where a termination is required. iCAN Network Connections The EG-2 has built-in network termination. If A removable 5 way connector screw terminal the EG-2 is at the end of the network, ensure plug is provided for the connection of iCAN the CAN TERMINATION jumper is fitted in the Termination On position.
  • Page 6 PC Node. Search the network and load the EG2 into the software. Go the Ethernet tab. Either the Default settings can be applied or other settings can be applied. Select OK or Apply to download the changes to the EG2. Cooper Lighting Solutions EG-2 9850-000776-01...
  • Page 7 Remove power from the board. Press the CAN ID button and reapply power. Keep the button pressed until the CAN LED flashes then stays on. At this point the Ethernet settings will have been restored to defaults. After setting to factory defaults, the IP address of the device will revert to 192.168.0.100 Cooper Lighting Solutions EG-2 9850-000776-01...
  • Page 8 Tel: +44 (0)844 324 9100 (available Mon-Fri 9am-5pm GMT) Email: cctechsupport@cooperlighting.com All products manufactured by Cooper Lighting Solutions are warranted to be free from defects in material and workmanship and shall conform to and perform in accordance with Seller’s written specifications. For detailed warranty information, contact Cooper Lighting Solutions.