Page 1
SWITCH & ENERGY Wi-R1S1-P Single relay with monitoring function network parameters www.fif.com.pl/fox/switchenergy F&F Filipowski sp. j.; Konstantynowska 79/81, 95-200 Pabianice, POLAND www.fif.com.pl; e-mail: biuro@fif.com.pl System capabilities » Communication via home Wi-Fi network; » Remote access to devices via the Polish F&F cloud;...
Page 2
Properties » 1-channel 230 V relay with 10 A rated capacity and 16 A ma- ximum capacity; » Ability to connect local control button and set its function; » Monitoring of network parameters: voltage, current, power (active and reactive), energy (active and reactive); »...
Page 3
Configuration For the initial configuration of the Fox module, it is necessary to download and run the free Fox application available for mobile devices running the system: » Android, version 5.0 or higher; » iOS, version 12 or higher. You can download the app directly from the stores: or via the website: www.fif.com.pl/fox...
Wiring diagram Description of terminals local control button input (default – R ON/OFF function) power supply – neutral wire (3×N terminals connected inside of the device) power supply – phase wire power output for R receiver It is recommended to use monostable (momentary) buttons.
Do not leave the device switched on without performing the personalization. There is a risk that another user of the Fox application will gain access to your device. If you lose access to your Fox device, follow the procedure de- scribed in Restore factory settings section.
Page 6
– Remote access Remote access configuration is necessary when you need to be able to access and control your Fox devices from outside your home when your phone app and Fox modu- les are not connected to the same local network. If you...
Page 7
– Password manager Each Fox device allows you to enter two passwords: an administrator who has full configuration and device con- trol rights, and a user who can control devices but without access to configuration settings. First, add passwords to the password manager. One or two predefined passwords are then substituted for the personalized controllers.
Page 8
– Calendar manager Allows you to add links to online calendars that can be used to program the operating cycle of Fox controllers. More information can be found at: www.fif.com.pl/fox. – Search...
Page 9
› Set the parameters of the Wi-Fi network (network name and password) to which the device will connect; Fox controllers can only connect to Wi-Fi networks ope- rating in the 2.4 GHz band. › Set other configuration parameters as necessary: user...
Page 10
If you personalize more devices, you can use the Set Defaults option at the top of the Device Configuration screen. Pressing this button will substitute all recently entered data (passwords, Wi-Fi settings, remote access, calendar, location and time zone) into the new device. - 10 -...
Page 11
LED signalling The status of the module can be directly assessed by the STATUS light located on the front of the device. The grey color actually corresponds to the green LED and the black color to the red LED. Controller in factory mode Connecting to a Wi-Fi network...
In case of lack of access to the controller, for example due to lost passwords, it is recommended that you reset the access passwords and then reconnect and configure the controller using the Fox application. To reset passwords: 1. While the controller is operating, press and hold the PROG button on the front of the controller.
Page 13
Technical data power supply 85÷265 V AC control input control voltage 85÷265 V AC control pulse current <1 mA maximum load current (AC-1) rated current 10 A maximum current (instantaneous) 16 A power consumption standby <1,2 W operation (relay on) <2 W communication radio frequency 2.4 GHz transmission Wi-Fi radio power (IEEE 802.11n)
Warranty F&F products are covered by a 24-month warranty from the date of purchase. The warranty is only valid with proof of purchase. Contact your dealer or contact us directly. CE declaration F&F Filipowski sp. j. declares that the device is in conformity with the essential requirements of Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the...