Download Print this page

EMX Industries CellOpener-365 Instruction Manual

Gsm access control with yearly & weekly timer

Advertisement

Quick Links

Instruction Manual
This GSM access control system allows up to 2000 registered users to operate any garage door /
gate using their phone with no cost for the call to the user. This simple to use access control
system uses a GSM SIM card that must be activated upon installation. Simply dial the associated
phone number for the SIM Card from any phone or mobile-phone and the gate will open
without any cost of a call to you. The CellOpener-365 also allows for an input contact to be used
to trigger a SMS text message to a property manager letting them know that someone is at the
gate or door.
In addition, the unit offers Weekly Timer and 365 Day Timer capability to offer maximum
security and allow a property manager to prevent a gate or overhead door from opening on
certain days and times such as national holidays or special events. The current date and time is
automatically set via the GSM network so there is never a reason to ever make adjustments for
daylight savings time.
All programming of the CellOpener-365 occurs using simple SMS text commands. This feature
allows programming to be done remotely from anywhere in the world making life easy for
maintenance, security and HR staffs that need to enable or disable an individual person's access
to a site.
Specifications
Power
Standby Current–LEDs enabled
Standby Current-LEDs disabled
Max Authorized Users
Relay Contact Rating
Operating Temperature
Antenna Cable Length
Lead Cable Length
EMX Industries, Inc.
CellOpener-365_Rev1.0_0601201
CellOpener-365
GSM Access Control
With Yearly & Weekly Timer
12V – 18V AC or DC
0.2A @ 12 VDC / 0.3A @ 24 VDC
0.1A @12
1600 Normal Users and 400 Special Users
5A @ 24V
Min -40°C / Max 65°C
1 m (39.4 inches)
0.5 m (19.7 inches)
Tech support: 216-518-9889
technical@emxinc.com
VDC / 0.15A @ 24 VDC
1/15

Advertisement

loading
Need help?

Need help?

Do you have a question about the CellOpener-365 and is the answer not in the manual?

Questions and answers

Summary of Contents for EMX Industries CellOpener-365

  • Page 1 SIM Card from any phone or mobile-phone and the gate will open without any cost of a call to you. The CellOpener-365 also allows for an input contact to be used to trigger a SMS text message to a property manager letting them know that someone is at the gate or door.
  • Page 2: Wiring Connections

    *Note: For solar applications, to reduce the current consumption of the unit, you can remove the jumper link on the right- hand side in the unit, to turn off the LEDs after the installation is complete. See diagram above. EMX Industries, Inc. Tech support: 216-518-9889 2/15 CellOpener-365_Rev1.0_0601201...
  • Page 3 *Note: Ignoring the warning message and not replying “YES ” within two minutes, will cause the unit to disregard the last command and the phone numbers would be saved and not be deleted. EMX Industries, Inc. Tech support: 216-518-9889 3/15 CellOpener-365_Rev1.0_0601201...
  • Page 4 9999AS.0418317435.3.0900.1700.1234567 9999 Is the password (default password 9999) Add Special number 0418317452 Is the phone number Allow only 3 entries (0-99) EMX Industries, Inc. Tech support: 216-518-9889 4/15 CellOpener-365_Rev1.0_0601201 technical@emxinc.com...
  • Page 5 For Latch Function 9999function For checking the current setting of the relay The unit will reply accordingly to the above commands by SMS as follows: Relay’s function is: Momentary Pulse of 1 second EMX Industries, Inc. Tech support: 216-518-9889 5/15 CellOpener-365_Rev1.0_0601201 technical@emxinc.com...
  • Page 6 The unit will reply by SMS according to the current status of the relay. If the relay is OFF the SMS reply would be: The relay is OFF If the relay is ON the SMS reply would be: The relay is ON EMX Industries, Inc. Tech support: 216-518-9889 6/15 CellOpener-365_Rev1.0_0601201 technical@emxinc.com...
  • Page 7 SMS: *9999 Is the password (default password 9999) 9999users The unit will reply by SMS: There are #### normal users and ### special users in the system EMX Industries, Inc. Tech support: 216-518-9889 7/15 CellOpener-365_Rev1.0_0601201 technical@emxinc.com...
  • Page 8 9999hold The unit will reply by SMS: Hold Command is ON To cancel the Hold Command send SMS as follows: 9999release The unit will reply by SMS: Hold Command is OFF EMX Industries, Inc. Tech support: 216-518-9889 8/15 CellOpener-365_Rev1.0_0601201 technical@emxinc.com...
  • Page 9 To proceed and factory reset the unit, you must confirm within 2 minutes by SMS in all capital letters: The unit will confirm by SMS: The unit was set to factory default EMX Industries, Inc. Tech support: 216-518-9889 9/15 CellOpener-365_Rev1.0_0601201...
  • Page 10 9999RS._ _ _ (Max 25 characters) _ _ _._ _ _ (Max 25 characters)_ _ _ Example: 9999RS.The Alarm is ON.The Alarm is OFF. 9999 Default password Status input-1 Delineates between the functions EMX Industries, Inc. Tech support: 216-518-9889 10/15 CellOpener-365_Rev1.0_0601201 technical@emxinc.com...
  • Page 11: Weekly Timer

    The weekly timer can be set to turn ON and OFF the internal relay on certain days and at certain time intervals. For example; to turn ON the relay at 7:00AM and turn it OFF at 17:00PM on each EMX Industries, Inc. Tech support: 216-518-9889 11/15 CellOpener-365_Rev1.0_0601201...
  • Page 12 Saturday. Also, it will turn ON at 08:00AM and turn OFF at 13:00PM each Tuesday, Wednesday and Thursday. And turn ON at 07:30AM and OFF at 15:00PM each Friday. *Note: The following SMS command is wrong: 9999WT.0900.1700.127,0800.1300.234,0730.1500.6 This is because the command contains two time intervals for MONDAY. EMX Industries, Inc. Tech support: 216-518-9889 12/15 CellOpener-365_Rev1.0_0601201...
  • Page 13 The unit will reply by SMS with all the time schedules in the system as in the example below: No events are recorded for the Weekly Timer Or for example: The Weekly Timer is ON: Sunday, Monday, Saturday, between 9:00AM and 17:00PM EMX Industries, Inc. Tech support: 216-518-9889 13/15 CellOpener-365_Rev1.0_0601201...
  • Page 14: Yearly Timer

    The yearly timer will take control of the weekly timer and set the relay to OFF during the above days and time interval. The unit will reply by SMS that says: Confirming: Yearly Timer OFF: 01.09.20, from 07:00AM until 02.09.20 24:00PM Another example: 9999YT.050119.0000.050119.2400.ON EMX Industries, Inc. Tech support: 216-518-9889 14/15 CellOpener-365_Rev1.0_0601201 technical@emxinc.com...
  • Page 15 3. How to Clear All the Yearly Timer’s Settings & Events Send SMS: 9999YT.clear The unit will reply by SMS that says: No events are recorded for the Yearly Timer EMX Industries, Inc. Tech support: 216-518-9889 15/15 CellOpener-365_Rev1.0_0601201 technical@emxinc.com...