TechnoTrade L2D Technical Manual

Ifsf protocol with lon interface to dart protocol with rs-485 interface

Advertisement

Quick Links

L2D converter
IFSF protocol with LON interface
to DART protocol with RS-485 interface
TECHNICAL GUIDE
Review date: 1 December, 2021

Advertisement

Table of Contents
loading

Summary of Contents for TechnoTrade L2D

  • Page 1 L2D converter IFSF protocol with LON interface to DART protocol with RS-485 interface TECHNICAL GUIDE Review date: 1 December, 2021...
  • Page 2: Table Of Contents

    L2D CONVERTER TECHNICAL GUIDE Revision: R01 Review date: 1 December, 2021 CONTENT PURPOSE OF THE DOCUMENT ..........................3 TECHNICAL FEATURES ............................4 Appointment ..............................4 Technical characteristics..........................5 Communication ............................. 5 CONNECTIONS ............................... 6 Connectors overview ............................. 6 Connection diagram ............................8 MECHANICAL DIMENTIONS ..........................
  • Page 3: Purpose Of The Document

    Technotrade LLC reserves a right to make changes to this document at any time without notice. Prospective users of this document should contact Technotrade LLC at the time they wish to use L2D converter together with their products to become aware of any updates that may apply.
  • Page 4: Technical Features

    POS system thinks that it communicates with IFSF-LON dispenser, no changes from POS are needed. L2D interface converter can be applied with any POS system able to work with IFSF protocol LON interface for provision of control over dispensers.
  • Page 5: Technical Characteristics

    L2D CONVERTER TECHNICAL GUIDE Revision: R01 Review date: 1 December, 2021 Technical characteristics PARAMETER VALUE Power supply voltage 100 V – 270 V AC Sealing IP20 Material ABS Plastic Temperature range from 0°C to +40°C Weight 0.45 kg Overall dimensions...
  • Page 6: Connections

    L2D CONVERTER TECHNICAL GUIDE Revision: R01 Review date: 1 December, 2021 CONNECTIONS Connectors overview CONNECTOR DESCRIPTION Main power connector LON interface connector RS-485 interface connector www.technotrade.ua page 6 from 22...
  • Page 7 L2D CONVERTER TECHNICAL GUIDE Revision: R01 Review date: 1 December, 2021 Connector X15 X15 is the connector where the main power is connected to L2D. CONNECTOR DESCRIPTION Earth Neutral Line CAUTION! High voltage is supplied to the device. A potential of shock hazard exists. Always connect and...
  • Page 8: Connection Diagram

    Revision: R01 Review date: 1 December, 2021 Connection diagram The below diagram describes graphically the way of connecting L2D for bridging the DART dispenser with the IFSF-LON network where the POS systems(s) and the other fuel dispensers are. www.technotrade.ua page 8 from 22...
  • Page 9 L2D CONVERTER TECHNICAL GUIDE Revision: R01 Review date: 1 December, 2021 In case if L2D converter is used together with PTS-1 PTS-2 controllers – then they can convert the protocol to any other pump protocol. Example of connection to PTS-1 controller: www.technotrade.ua...
  • Page 10 L2D CONVERTER TECHNICAL GUIDE Revision: R01 Review date: 1 December, 2021 Example of connection to PTS-2 controller: www.technotrade.ua page 10 from 22...
  • Page 11: Mechanical Dimentions

    L2D CONVERTER TECHNICAL GUIDE Revision: R01 Review date: 1 December, 2021 MECHANICAL DIMENTIONS www.technotrade.ua page 11 from 22...
  • Page 12: User Interface

    USER INTERFACE S1 and S2 buttons Buttons S1 and S2 are used to set the L2D converter in preliminary defined state according to IFSF-LON specification. By pressing and keeping both of these buttons pressed in power-off state at powering on the device all of the configuration parameters are reset to their default values.
  • Page 13: Control Keys

    NAME FUNCTION OK / MENU When L2D converter is in the main screen pressing on this key leads to entering the menu. When modifying a parameter from the settings pressing this key confirms the changes. Navigates through menus or parameters up increasing the value of the...
  • Page 14: Configuration

    3. LON POS status – describes whether the POS over IFSF-LON is online or offline. 4. LON PUMP Status – describes what pump status is sent by L2D over the IFSF-LON network; 5. LON-line events – shows all related events (like heartbeats) over the IFSF-LON network;...
  • Page 15 Set POS and LON communication debug These parameters only affects the levels. service logging. No impact on the normal communication flow. RESET Performs software reset of L2D Bridge. COLD START Cold start will bring the device to factory default setting www.technotrade.ua page 15 from 22...
  • Page 16 L2D CONVERTER TECHNICAL GUIDE Revision: R01 Review date: 1 December, 2021 SETTINGS > DEVICE > COMMON This menu allows adjustment of the following device-parameters: PARAMETER DESCRIPTION OPTIONS DEFAULT VALUE LANGUAGE Set the default menu language for the ENG – English device SWH –...
  • Page 17 SETTINGS > DEVICE > DEBUG LEVEL Adjust device debug levels. These parameters are used only for service purposes during logging and do not affect the normal communication of L2D with the other devices. Below the parameters included in the menu:...
  • Page 18 L2D CONVERTER TECHNICAL GUIDE Revision: R01 Review date: 1 December, 2021 After entering the password the screen and actions are similar to RESET menu. The Cold Start is executed when quitting this menu: SETTINGS > POS SETTINGS > POS > DECIMALS A 4 digits password is needed to enter to that option (default password is 2345).
  • Page 19 SETTINGS > LON > COMMON Set the LON-network node address. It is important to make sure that the device is set with a unique address in the connected LON-network. From POS-system prospective the L2D-bridge appears as dispenser and its node-address.
  • Page 20 L2D CONVERTER TECHNICAL GUIDE Revision: R01 Review date: 1 December, 2021 SETTINGS > IFSF > COMMON Specifies the pump parameters that are needed for the proper work of the IFSF-protocol and they (or some of them) are not provided by the real dispenser over the protocol.
  • Page 21 Set the common pump parameters COMM Set pump communication parameters DECIMAL Set the decimal points for the pump SETTINGS > PUMP > COMMON This menu sets the parameters from pump-control side of L2D converter. ## PARAMETER DESCRIPTION OPTIONS DEFAULT VALUE PUMP...
  • Page 22 L2D CONVERTER TECHNICAL GUIDE Revision: R01 Review date: 1 December, 2021 SETTINGS > PUMP > DECIMAL A 4 digits password is needed to enter to that option (default password is 2345). After entering the proper password the following parameters are seen: Each FP (PUMP) can have its own decimal point settings.

Table of Contents