Troubleshooting - Offgridtec PSI-Pro Series Manual

Table of Contents

Advertisement

Available languages

Available languages

6 Troubleshooting

A high voltage occurs in the inverter. DO NOT attempt to repair or maintain the inverter
itself; This can cause an electric shock.
Lcd
General information
Offgridtec GmbH
Im Gewerbepark 11
84307 Eggenfelden
WEEE-Reg.-Nr. DE37551 136
Error
Reasons
The blue
indicator
The DC input voltage is
flashes
too low.
slowly.
Buzzer
beeps.
Blue
indicator
The DC input voltage
flashes
is too high
quickly.
Buzzer
beeps.
The red
indicator
flashes
Overload
quickly.
Buzzer
beeps.
Red
indicators
flashing
Load short circuit
quickly.
Buzzer
beeps.
Contact
Tel: +49 8721 91994-00
Email: info@offgridtec.com
Web: www.offgridtec.com
GFR: Christian & Martin Krannich
Offgridtec PSI-PRO Inverter
Troubleshooting
Check that the DC input
voltage is lower than
10.8/21.6V.
The inverter resumes work
after the input voltagehas been
e-handed.
Check that the DC input voltage is
higher than 16/32V.
The inverter resumes work after the
working voltage range has been
reached again.
Reduce rated power at the AC
output and restart the inverter.
Check the connection of the
loads carefully.
Delete the short-circuit errors
and restart the inverter.
Konto Sparkasse Rottal-Inn
Konto: 10188985
BLZ: 74351430
IBAN: DE69743514300010188985
BIC: BYLADEM1EGF (Eggenfelden)
6 Troubleshooting
Sitz und Amtsgericht
HRB: 9179 Registergericht Landshut
Steuernummer: 141/134/30045
Ust-IdNr: DE2871 1 1500
Gerichtsstand: Mühldorf am Inn

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Psi-pro 12/2000Psi-pro 12/3000Psi-pro 24/3000

Table of Contents