Download Print this page

Datasensor S62 B Series Instruction Manual

Advertisement

Quick Links

S62...B
Polarised retroreflex
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (yellow)
The yellow LED ON indicates the following output
status: N.O. closed and N.C. open.
STABILITY LED (green)
The green LED permantely ON indicates a stable
operating condition, where the signal received has a
safety margin higher than 30% respect to the output
switching value. The sensor is ready to function
correctly.
SENSITIVITY TRIMMER (ADJ.)
A mono-turn trimmer adjusts the sensitivity and the
sensor operating distance.
See the "SETTING" paragraph for the functioning
mode.
NOTE: the maximum trimmer mechanical rotating
range is equal to 240°. Do not force over the maximum
e minimum positions.
INSTALLATION
The
sensor
can
be
positioned by means of
the
three
housing's
holes using two screws
(M4x25 or longer, 1.5
Nm maximum tightening
torque) with washers.
Various orientable fixing
brackets to ease the sensor positioning are available
(please refer to the accessories listed in the
catalogue).
The operating distance is measured from the front
surface of the sensor optics.
The M12 connector can be oriented at two different
positions using the specific fastening spring and
rotating the block of 180°.
TECHNICAL DATA
Power supply:
Ripple:
Current consumption
(output current excluded):
Outputs:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Indicators:
Setting:
Operating temperature:
Storage temperature:
Dielectric strength:
Insulation resistance:
Operating distance (typical values):
Emission type:
Ambient light rejection:
Vibrations:
0.5 mm amplitude, 10 ... 55 Hz frequency, for each axis (EN60068-2-6)
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
CONNECTIONS
Alignement:
- Align sensor and reflector on opposite sides at the necessary
distance.
- Rotate in the clockwise direction the sensitivity adjustment
trimmer (ADJ.) to maximum level.
- Moving the sensor vertically and horizontally, establish the
powering and turning off of the yellow LED (OUT) and fix the
sensor at in the middle. The best alignment is obtained in the
following condition: yellow LED permanently OFF and green
LED permanently ON.
Control:
- Place the target between the
sensor and the reflector. Control
that the yellow LED turns ON.
- Remove the target and control
that the yellow LED turns OFF again.
10 ... 30 Vdc (limit values)
2 Vpp max.
< 30 mA
PNP or NPN N.O. / N.C.; 30 Vdc max. (short-circuit protection)
100 mA max (overload and overvoltage protection)
≤ 2 V
500 µs max.
1 kHz
OUTPUT LED (YELLOW) / STABILITY LED (GREEN)
mono-turn sensitivity adjustment trimmer
-10 ... 55 °C
-20 ... 70 °C
500 Vac / 1 min. between electronic parts and housing
>20 MΩ / 500 Vdc, between electronic parts and housing
0.1...8 m su R2 (EG = 2)
RED (640 nm)
according to EN 60947-5-2
11 ms (30 G) 6 shocks for each axis (EN60068-2-27)
ABS
window in PMMA, lenses in polycarbonate
IP67
2 m ∅ 4 mm cable / M12 4-pole connector
90 g. max. (cable version) / 40 g. max. (connector version)
SETTING
DIMENSIONS
50
18
42
4.7
11 6
14
M12
Ø15
SENSITIVITY TRIMMER
25
CABLE VERSION
6.18
10.7
STABILITY LED
OUTPUT LED
EX-II-3D T6
T6 (<85°C)
Temperature class:
Max. Power consumpti 540 mW at 30 Vdc
Max. Internal capacitan 100 nF
Internal inductance:
negligible
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that
these products are conform to the 2004/108 CEE, 73/23 CEE Directives
and successive amendments.
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product
found to be defective during the warranty period of 36 months from the
manufacturing date.
This warranty does not cover damage or liability deriving from the
improper application of DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611
Fax: +39 051 6759324
http://www.datasensor.com
e-mail: info@datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled
paper.
DATASENSOR S.p.A. reserves the right to make modifications
and improvements without prior notification.
826003020 Rev.00
mm

Advertisement

loading

Summary of Contents for Datasensor S62 B Series

  • Page 1 DATASENSOR S.p.A. warrants its products to be free from defects. Nm maximum tightening following condition: yellow LED permanently OFF and green DATASENSOR S.p.A. will repair or replace, free of charge, any product torque) with washers. LED permanently ON. found to be defective during the warranty period of 36 months from the Various orientable fixing manufacturing date.
  • Page 2 M12 connector DATASENSOR S.p.A. warrants its products to be free from defects. DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the warranty period of 36 months from the manufacturing date. This warranty does not cover damage or liability deriving from the improper application of DATASENSOR products.
  • Page 3 DATASENSOR S.p.A. warrants its products to be free from defects. DATASENSOR S.p.A. will repair or replace, free of charge, any product The M12 connector can be oriented at two different positions found to be defective during the warranty period of 36 months from the using the specific fastening spring and rotating the block to manufacturing date.
  • Page 4 WARRANTY DATASENSOR S.p.A. warrants its products to be free from defects. DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the warranty period of 36 months from the manufacturing date. This warranty does not cover damage or liability deriving from the improper application of The trimmer reaches maximum level with yellow LED OFF if the background DATASENSOR products.

This manual is also suitable for:

S62-m0 seriesS62-m1 seriesS62-m2 seriesS62-m3 seriesS62-pl b seriesS62-pl-m01 series ... Show all