Do you have a question about the 1.5CFM-BL and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Asada 1.5CFM-BL
Page 1
AIR CONDITIONING TOOL CORDLESS VACUUM PUMP1. 5CFM I N ST R U C T I O N MA NU A L 【Read through this manual carefully before using the pump.】...
Page 2
CORDLESS VACUUM PUMP 1.5CFM SAFETY PRECAUTIONS Thank you for choosing our Cordless Vacuum Pump. ● This instruction manual must be retained by the user of this pump. ● Read this instruction manual carefully and completely before use and thoroughly understand the usage, capacity, cautions and maintenance for correct operation. ●...
CORDLESS VACUUM PUMP 1.5CFM CAUTION IN USE ● Basic cautions to use the pump safely are listed in this section. ● The detailed cautions in operation are described in each chapter. WARNING ◆ Only qualified persons are allowed to disassemble the pump. ◆...
Page 5
CORDLESS VACUUM PUMP 1.5CFM WARNING ◆ Do not use the power cord concurrently with other electrical equipments and avoid overload connection. ◆ Do not pull the power cord to disconnect from the outlet. It may lead to electric shock, fire or injury. ◆...
Page 6
CORDLESS VACUUM PUMP 1.5CFM WARNING ◆ When battery cartridge is not in use, keep it away from other metal objects. Shorting the battery terminals together may cause burns or a fire. Always put battery cover on battery cartridge after removed it from tool or charger. ◆...
Page 7
CORDLESS VACUUM PUMP 1.5CFM WARNING ◆ Use only the accessories or attachments given in this manual and our catalogs. Otherwise it will lead to accident or mechanical failure. ◆ Do not use a battery cartridge which operating time has become exessively shorter.
Page 8
CORDLESS VACUUM PUMP 1.5CFM WARNING ◆ Do not store the pump and battery cartridge in locations where the temperature may reach or exceed 50℃ (122℉ ). ◆ The pump is stored in indoor ambient temperature 5℃ ~ 40℃ . ◆ Use charger under the condition of normal rated power. Do not use transformer, DC power and engine generator.
Page 9
CORDLESS VACUUM PUMP 1.5CFM CAUTION ◆ An extension cord used should be a length of 30m or less when its diameter is 2.0㎡ . An unsuitable extension cord (too thin or too long) may lead to starting failure or fire. ◆...
CORDLESS VACUUM PUMP 1.5CFM COMPONENTS OF THE MACHINE Main Parts 1.5CFM-B Oil fill / exhaust cap Handle Intake shut-off valve Battery holder Sight glass Battery cartridge Power switch Oil drain plug Base LED lamp Oil tank Motor...
CORDLESS VACUUM PUMP 1.5CFM OPERATION BATTERY CARTRIDGE AND CHARGER Battery Protection System The pu m p is e qu ipp ed wit h a bat t ery protection system. This system automatically cuts off power to the motor to extend battery ★marking life.
CORDLESS VACUUM PUMP 1.5CFM Charging Battery Cartridge ① Plug the battery charger into the proper AC voltage Battery cartridge source. Charge light will Terminal cover flash in green repeatedly. Charging ② Insert the battery cartridge indicator light into charger until it stops adjusting to the guidde of c h a r g e r .
CORDLESS VACUUM PUMP 1.5CFM Changing Melody Of Completed Charging ① Inserting the battery cartridge into charger brings out last preset brief melody(※) sound of completed charging. ② Removing and re-inserting it within five seconds after this action makes the melody sound change. ③...
CORDLESS VACUUM PUMP 1.5CFM Caution In Use ● The charger is for charging Makita-battery cartridge. Never use it for other purpose or for other manufacturer's batteries. ● Sometimes red light lights up when charge the battery immediately after use and put in direct sunshine for long time. In this case, start charging after cool down the battery with cooling fan of charger.
CORDLESS VACUUM PUMP 1.5CFM Conditioning Charge ● Conditioning charge can extend the batter life by automatically searching the optimum charging condition for the batteries in every situation. ● The battery employed in the following conditions repeatedly requires "conditioning charge" to prevent fast wear out. In that case yellow light lights up.
CORDLESS VACUUM PUMP 1.5CFM Installing Or Removing Battery Cartridge WARNING Always install the battery cartridge fully until the red indicator cannot be seen. If not, it may accidentally fall out of the pump, causing injury to you or someone around you. ①...
CORDLESS VACUUM PUMP 1.5CFM OPERATION The pump does not contain oil when newly purchased. Refer to "Adding oil" and add oil. WARNING Operating the pump in the condition without oil added will damage the pump. In addition, the oil tank will become hot and may result in burns or other accidents.
CORDLESS VACUUM PUMP 1.5CFM Operation(evacuation work) ① Connect the pump, manifold and outdoor unit with hoses. Note: When the outdoor unit service port size is 1/4", use the supplied different diameter adapter. Manifold High side valve side valve Close Close Intake shut-off...
CORDLESS VACUUM PUMP 1.5CFM ⑧ Leave the pump and manifold for 5 minutes or more. If the pressure of the manifold does not rise, there are no leaks. Manifold Leave for more than 5 minutes Check preussure gauge does not rise High side valve side valve...
● Change oil every 20 hours operation. ● Change oil after every operation when the pump is used for an old system. Sight glass ● Use Asada genuine oil for best performance. Replacing The Oil ① Open the intake shut -off valve. Intake shut-off...
CORDLESS VACUUM PUMP 1.5CFM MAINTENANCE & INSPECTION Vacuum pump oil: The condition and type of oil used in any high performance vacuum pump are extremely important in determining the ultimate attainable vacuum. It is recommended to use the High Performance Vacuum Pump Oil, which is specifically blended to maintain maximum viscosity at normal temperatures and to improve start up under cold weather.
CORDLESS VACUUM PUMP 1.5CFM TECHNICAL INFORMATION Electrical Wiring Diagram Black - +18V +18V Motor + Black MOTO AS terminal Yellow/Green Circuit board Power switch CE Declaration Of Conformity We, acting in sole responsibility, declare that this product complies with the regulation of the directives 2006/42/EC, 2014/30/EU, 2011/65/EU.