Step
18 Remove the wire
saddle.
19 Disconnect the
connector [S80].
20 Pull out the clamp.
21 Disconnect the relay
connector for the
compressor.
10
Procedure
Wire saddle
[S80]
Points
(R16800)
[S80]: four way valve coil
The cooling only models
have no harness for [S80].
When reassembling, insert
the clamps of harnesses as
below.
[S40] [S80]
(R16801)
When reassembling,
connect the connectors in
the following order.
(1) [S80]
(2) [S20]
(3) [S40]
(4) [S70]
(R16802)
(R14312)
Si001274EC
[S20]
(R14363)
Removal Procedure