MSE MS-2410C User Manual

Advertisement

AC to DC24V UNINTERRUPTED POWER SUPPLY

Specifications and Features:

 Total 210W Max.
DC power output 8A Max. (@24V)
Charge current 7.5A Max. (@28V)
 Net weight, only 4.63 lbs/2.1kg
 Dimensions 252*54*190 m/m (W*H*D)
 Over Voltage protection
 Over Current protection
 Quiet Internal Cooling Fan
 Input Voltage: Selectable AC input voltage
-115 Vac at 50/60Hz (5.1A@F.L.)
-230 Vac at 50/60Hz (2.6A@F.L.)
 Super Regulation:
Works with AC input from 90 to 265Vac (SWITCH SELECT)
 Back-up Power Supply System
 Compatible with Solar and Wind Charge Controllers
MSE
MS-2410C
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS-2410C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MSE MS-2410C

  • Page 1 MS-2410C AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual Specifications and Features:  Total 210W Max. DC power output 8A Max. (@24V) Charge current 7.5A Max. (@28V)  Net weight, only 4.63 lbs/2.1kg  Dimensions 252*54*190 m/m (W*H*D)  Over Voltage protection ...
  • Page 2 PANEL DESCRIPTION Item Name Description Power Switch Control AC power On or Off, WET Flooded battery Battery Type Selector AGM AGM battery (default) Battery On/Off Switch Control Battery On or Off LOAD Load Indicator Light GREEN when the LOAD is working Light YELLOW when the model with AC input and PWR AC Power Indicator power switch is on...
  • Page 3  INSTALLATION: Before plugging in the model to an AC outlet, please make sure that the proper input voltage is selected on the rear of the unit. Select 115V for 100/110/120 AC operation or 230V for 200/220/240 AC operation. The factory default setting is 230V. Then, connect your device to the LOAD terminal and connect a lead acid battery to the BATTERY terminal, make sure the polarity of battery is correctly connected, select WET for wet battery, AGM for AGM battery, default setting is AGM...
  • Page 4  OPERATION: The PS works as a DC UPS (Uninterruptible Power Supply) or as a backup power supply system. When AC power is applied normally, the model offers a regulated 24V DC output at LOAD terminal for devices and a charging current output on BATTERY terminal for charging a lead acid battery at the same time.
  • Page 5 When the charger is in charging mode and charge current is more than 2.5A, the CHG indicator light will be YELLOW, when charge current is lower than 1.8A, the charger turns to maintenance mode, the CHG light is off and CHD light is GREEN. All LED indicators will turn off when AC fails except BATT and battery type indicator (WET or AGM).
  • Page 6 5. The cables for battery connection or device to the PS should be 16AWG min. Please keeping the connect points clean to avoid spark or electrical leakage. 6. When connecting a solar panel or wind turbine controller to the PS, please make sure of the correct polarity.
  • Page 7  PROTECTION DESCRPTION: Battery Polarity Reverse Protection: when the battery polarity is reversed, the BATT indicator light will display RED and the BATTERY and LOAD terminals will terminate output. Battery reverse will not damage the model if the AC power is off. The AC switch must be turned off at any time when the battery is changed.

Table of Contents