Page 1
GJD D-TECT Laser User Manual LASER SCANNERS FOR BUILDING AUTOMATION AND SECURITY GJD509 : max. detection range of 10m x 10m GJD505 : max. detection range of 5.0m x 5.0m...
SAFETY The device contains IR and visible laser diodes. IR laser: wavelength 905nm; max. output pulse power 75W (Class 1 according to IEC 60825-1) Visible laser: wavelength 650nm; max. output CW power 3mW (Class 3R according to IEC 60825-1) The visible laser beams are inactive during normal functioning. The installer can activate the visible lasers if needed.
Page 3
DESCRIPTION laser sweep emission protection cover laser sweep reception visible laser beam (3) LED-signal (4) notch for tilt angle adjustment (2) screw for position lock (2) adjustable bracket connector cable conduit (4) LED-SIGNAL 1. Detection LED: relay 1 - optional field LED flashes quickly 2.
Page 4
MOUNTING Left Side Mounted Right Side Mounted Use the adhesive mounting Pass the cable +/- 10 cm though Drill 4 holes as indicated on the template to position the sensor mounting template. Make a hole the cable opening. If drilling an correctly.
Page 5
WIRING GREEN POWER SUPPLY + (Recommended Power Supply 24 VDC - PRIMARY GJD’s ALT-100-24 ) POWER SUPPLY - BROWN WHITE RELAY 1 - OPTIONAL FIELD YELLOW PINK RELAY 2 - SAFETY FIELD VIOLET POWER SUPPLY + (Both primary and secondary power cables...
Page 6
MOUNTING SIDE Stay outside of the detection field to avoid disturbances. Select the corresponding mounting side. The sensor learns its environment and automatically determines the detection field(s). Both RED LEDs flash slowly and the 3 visible laser beams automatically light up during 30 seconds. CAT 2 CAT 2 right...
Page 7
REMOTE CONTROL ADJUSTMENTS DETECTION CURTAINS C1 + C2 active on optional field only CURTAIN C3 + C4 active on safety field only deactivate curtain on both fields C1 active on both fields activate curtain only on optional field C2+C3 active on safety field only C4 deactivated activate curtain only on safety field activate curtain on both fields...
Page 8
OPTIONAL FIELD CONFIGURATIONS Make sure the white and yellow wires are connected to the corresponding inputs before you choose one of the following two configurations. VIRTUAL PUSH BUTTON Install 1 or 2 virtual push buttons as activation zone(s) to open the door «manually». Apply the vitual push button sticker(s) within the opening field.
HOW TO USE THE REMOTE CONTROL After unlocking, the red If the red LED flashes quickly after unlocking, you To end an adjustment session, LED flashes and the sensor need to enter an access code from 1 to 4 digits. always lock the sensor.
TROUBLESHOOTING There is no power. No blue LED Check cable and connexion. The polarity of the power Check the polarity of the power supply. supply is inverted. All LEDs have been de- Activate the LEDs by remote control. activated by remote control. Only the blue LED The test input is not Check wiring.