Filtration Group MFS-05 Translation Of The Original Instructions

Filtration Group MFS-05 Translation Of The Original Instructions

Advertisement

Quick Links

Translation of the original instructions
Filter controller MFS-05 ∆p
Material No. of Instruction Manual
70303409

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MFS-05 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Filtration Group MFS-05

  • Page 1 Translation of the original instructions Filter controller MFS-05 ∆p Material No. of Instruction Manual 70303409...
  • Page 2: Table Of Contents

    20 Declaration of incorporation ........19 Potentially dangerous situation! 21 Declaration of conformity ........20  Non-observance can result in property damage. 22 Index ................24 Page 2 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 3: Other Symbols Used

    Temperature hysteresis: Response inertia to a change in temperature. Temperature drift: Temperature sensitivity of the transistor characteristics. Page 3 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 4: Intended Application

    Fig. 1: Controls, LEDs and displays Interval time Pulse time Potentiometers: The time settings have a logarithmic scale with a control range of 240°. Page 4 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 5 The ∆p zero adjusting screw is located to the right of the LC display. Fig. 8: TEST button S1 Fig. 6: Zero adjustment Page 5 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 6: Technical Data

    • Interval time: 5 ... 500 s • Post-cleaning: 0 ... 12 cycles • Operation: Green LEDs • Cleaning: Yellow • Fault: Red Page 6 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 7: Transport And Storage

    • Find and plot the 70 s line.  The point of intersection is located on characteristic 60. • Set the “interval” potentiometer to 60 s. Page 7 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 8: Switching Threshold

    Fig. 16: Jumper settings for time control A time-controlled cleaning process starts if contacts 16-17 and 18-19 are closed. Fig. 14: Jumper settings for full cycle Page 8 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 9: Secondary Functions

    • Acknowledge the fault by applying a momentary contact signal at terminals 18 and 21.  The fault signal is reset. Fig. 20: Cleaning Fig. 18: Fault Page 9 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 10: Alarm Threshold

    • Provide the necessary sealing components (e.g. seals) for the specified degree of protection. Page 10 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 11: Normal Operation

    • A settable differential pressure must be supplied for the duration of the test. Alternatively: • Test the controller in “time control” mode (terminals 16-17 and 18-19 jumpered). Page 11 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 12: Maintenance, Repair And Retrofitting

    • The use of rewired fuses is prohibited, as is short- circuiting the fuse holder. • • Page 12 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 13: Appendix: Connection Variants

    Appendix: Connection variants 15.1 Interval time and switching threshold control Page 13 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 14: Terminal Assignment

    Valve 18 Valve extension Valve 19 Valve 20 Valve 21 Valve 22 Valve 23 Valve 24 Malfunction/ Δp Alert operation Lag/Discharge RS 485 Page 14 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 15: Appendix: Rs 485 Serial Port

    Δ p reference “S” 83 hex Δ p da “T” 84 hex Other 32000 Unknown query characters div = Integer division with no remainder Page 15 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 16: Appendix: Set Of Instrument Lines And Protective Filter (Id No. 78341984)

    Membrane filter Ti 56 Snap ring Bottom side coated 15x1 DIN 472 1.4310 78342032 77749500 Fig. 23: Installation drawing and spare parts Page 16 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 17: Appendix: Dimension Drawing Mfs-05 Δp

    Appendix: Dimension drawing MFS-05 Δp Fig. 24: Connection diagram for optional pressure switch Page 17 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 18: Appendix: Default Settings

    Terminals 16-17 and 18-19 jumpered Interval time 600 divided by the number of valves n Jumper settings Schw./Reg. jumper Down T/G Cycle jumper Page 18 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 19: Declaration Of Incorporation

    Declaration of incorporation As defined by the EC Machinery Directive. Page 19 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 20: Declaration Of Conformity

    Declaration of conformity Page 20 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 21 Page 21 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 22 Page 22 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 23 Page 23 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 24: Index

    Transport and storage ............7 Jumper ............5, 7, 8, 11, 19 Warning symbols ..............2 Leakage ................2 Warnings ................2 Zero adjustment ..............5 Page 24 Translation of the original instructions MFS-05 Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03...
  • Page 25 Filtration Group GmbH Schleifbachweg 45 D-74613 Öhringen Phone +49 7941 6466-0 Fax +49 7941 6466-429 fm.de.sales@filtrationgroup.com www.filtrationgroup.com 70303409.I03.01/2018...

Table of Contents