Page 3
Mounting When raised the toilet’s lid and seat must not obstruct the Wave unit in any way Step 1 Cut recess into wall or panelling. Important: For exact dimensions refer to xing template (enclosed), ensuring that the correct cutting line is used corresponding to Mounting Options 1, 2 or 3 below Step 2 Install mounting frame and bridging tunnel...
Page 4
Connections Step 1 Connect pneumatic tubes. Full Flush Connect white/clear pneumatic tube to the port marked with a full round symbol. Partial Flush Connect green pneumatic tube to the port marked with a half round symbol. Step 2 Connect power supply Wiring Transformer Wire the transformer to a suitable 3A fused spur.
Page 5
Flush Boost If the ush test carried out in Section 3 failed on either or both ush options a Boost can be independently applied to deliver more air to the valve. Step 1 Press any rear button once to enter Boost Mode. The current boost setting will now be displayed for both full and partial ush.
Page 6
Activation Detection Range (ADR) Configuration The Activation Detection Range or ADR is the distance at which the unit rst detects a user and illuminates ready for use. There are 3 modes of setup used to congure the unit to its specic WC environment. Default The unit will give complete ushing functionality using the factory set default range of 2m.
Page 7
Locking the Unit Step 1 Locate the locking toggles. Step 2 Using a suitably sized screwdriver or allen key, turn the locking toggles inwards approximately 45° to the lock position.
Page 8
Operation Inactive When a user is outside the activation detection range (ADR) the icons are not illuminated. WAVE Activation When a user moves into the ADR, the ush icons will illuminate blue and remain so until the user moves out of range.