2) HDMI_2 .
[3]
=> Detail EDID Options are below([1],[2],[3],[4],[5])
* Please refer HDMI_1.
3) HDMI_3.
[3]
=> Detail EDID Options are below([1],[2],[3],[4],[5])
* Please refer HDMI_1.
Copyright©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
[1]
[4]
[1]
[4]
* Before adjusting White-balance, the AV ADC should be done.
If ADC status were "NG", Need to ADC adjustment.
[2]
9. Adjustment of White Balance
9-1. Required Equipment
(1) Remote control for adjustment.
(2) Color Analyzer : CS-1000, CA-100,100+, CA210 or same
[5]
* Please adjust CA-210+, CA-100+ by before measuring.
(3) Auto W/B adjustment instrument.(only for Auto adjustment)
(4) AV Pattern Generator.
(5) 15Pin D-Sub Jack(RGB) is connected to the AUTO W/B
EQUIPMENT.
9-2. AUTO White Balance Process
- Adjust Process will start by execute I2C Command(Inner
[5]
pattern (0xF3, 0xFF)).
W
Color temperature standards according to CSM and Module.
CSM
Cool
[2]
Normal
Warm
W
CS-1000/CA-100+/CA-210(CH 10) White balance adjustment
coordinate and color temperature.
[5]
CSM
COOL
MEDIUM
WARM
[5]
9-3. Manual W/B process
(using adjusts Remote control)
* Please Adjust in AV 1mode
(1) Enter 'PICTURE RESET' on Picture Mode, then off Fresh
Contrast and Fresh colour in Advanced Control.
(2) After enter Service Mode by pushing "ADJ" key.
(3) Enter White Pattern off of service mode, and change off ->
on.
(4) Enter "W/B ADJUST" by pushing "
ADJUST".
(5) Adjust W/B DATA, for all CSM, choose 'COPY All'.
- 9 -
product.: CH 10
PLASMA
Remark
11000K
9300K
6500K
Color Coordinate
x
y
0.276
0.283
11,000K
0.285
0.293
9,300K
0.313
0.329
6,500K
G
" key at "3. W/B
Temp
uv
0.002
0.002
0.002
LGE Internal Use Only