Mitsubishi Electric MSH-GE50VB-E1 Service Manual page 36

Table of Contents

Advertisement

OPERATING PROCEDURE
4. Removing the vane motor
(1) Remove the panel and the corner box. (Refer to 1.)
(2) Remove the electrical cover. (Refer to 2.)
(3) Remove the lead wire of vane motor. (Refer to 3.)
(4) Remove the R.L. holder.
(5) Pull out the drain hose from the nozzle assembly and
remove the nozzle assembly.
(6) Remove the screws of the vane motor and disconnect the
connector.
(7) Remove the vane motor.
Photo 5
Screws of the
vane motor
Vane motor
5. Removing the line flow fan and the indoor fan motor
(1) Remove the panel and the corner box. (Refer to 1.)
(2) Remove the electrical box. (Refer to 3.)
(3) Pull out the drain hose from the nozzle assembly and
remove the nozzle assembly.
(4) Remove the water cut.
(5) Slide the hole cover and remove the hole cover.
(6) Remove the hexagon socket set screw from the line flow
fan.
(7) Remove the screws of the fan motor and remove the fan
motor. (Be careful not to drop the fan motor because it is
heavy.)
(8) Remove the screws of the left side of the heat exchanger.
(9) Lift the left side of the heat exchanger.
(10) Remove the line flow fan.
Photo 8
Hole
cover
Copyright 2008 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD
Distributed in Aug. 2011. No.OBH529 REVISED EDITION-A
Distributed in Dec. 2008. No.OBH529 5
Made in Japan
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
PHOTOS
Photo 4
Vane motors
Photo 6
Screws of
the left side
of the heat
exchanger
Photo 7
Indoor coil
thermistor
Water cut
Screws of the fan motor
New publication, effective Aug. 2011
Specifications subject to change without notice.
Screws
of the
vane
motor

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc-ge20vb-e1Msc-ge25vb-e1Msc-ge35vb-e1Ms-ge50vb-e1

Table of Contents