Mitsubishi Electric MSH-GA60VB-E1 Service Manual page 19

Hide thumbs Also See for MSH-GA60VB-E1:
Table of Contents

Advertisement

9-6. Test point diagram and voltage
MSH-GA50VB MSH-GA60VB MSH-GA80VB
Indoor electronic control P.C. board
TYPE 1
Fuse (F11)
T3.15AL250V
R132
Receiver P.C. board
OB367D
To disable "Auto restart function",
CN301
solder the jumper wire to JR07.
(Refer to 8-3.)
w There are 2 types of electronic control P.C. boards
(TYPE1/TYPE2).
They are both compatible with MSH-GA50/60/80VB.
12 VDC
Indoor coil thermistor
(RT12 (main), RT13 (sub))
Room temperature thermistor (RT11)
19
Fan motor power supply
(CN211)
}
Power supply input
230 VAC
}
5 VDC
+
Room temperature ther-
mistor(RT11)
Indoor coil
thermistor(RT12 (main))
MSH-GA80VB
Indoor coil
thermistor(RT13 (sub))
CN121
Vane motor power
supply (CN151)
Emergency operation
switch
Timer short mode point
(JPS, JPG)
(Refer to 8-1.)
+

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msh-ga50vb-e1Msh-ga80vb-e1Muh-ga60vb-e1

Table of Contents