Contacts description................................10 LED Indications ..................................12 Mounting Recomendations ..............................13 4 COMMUNICATION PROTOCOL ............................15 Vega SI-12 pulse counter transmits the following types of packets ................15 Packet with current readings .............................15 “Alarm” packet ................................16 External power information packet...........................16 Output state information packet ..........................17...
Vega SI-12 / User Manual INTRODUCTION This manual is designated for Vega SI-12 pulse counter (hereinafter – the counter) manufactured by Vega-Absolute OOO and provides information on powering and activation procedure, control commands and functions of the counter. This manual is targeted at specialists familiar with installation work fundamentals for electronic and electrical equipment.
Vega SI-12 pulse counter is designed for counting of pulses incoming to 4 independent inputs, further accumulating and transmitting of this information to the LoRaWAN network In addition, Vega SI-12 can be used as a security device - all inputs can be configured as security inputs.
Page 5
Vega SI-12 / User Manual the "Active" mode. If all attempts fail, the counter will continue to accumulate data and will attempt to connect to the network every 6 hours. Hold the start button pressed (min. 5 seconds) to switch the device from the "Active"...
Vega SI-12 / User Manual FUNCTIONAL Vega SI-12 pulse counter can be either of A class or C class (LoRaWAN classification) and has the following features: Automatic change from A class to C class when powered from an external power...
Vega SI-12 / User Manual 2 SPECIFICATION DEVICE SPECIFICATION MAIN Double-contact digital inputs up to 4 Maximum input frequency 200 Hz Security inputs up to 4 Open-drain outputs USB-port mini-USB, type B Operating temperatures -40…+85 °С Built-in temperature sensor LORAWAN ®...
Vega SI-12 / User Manual DEFAULT DEVICE SETTINGS PARAMETER VALUE RU868 Frequency plan OTAA Activation type Adaptive Data Rate Confirmed Uplinks 1 second Rx 1 Delay 5 seconds Join Accept Delay Uplink number of transmissions Data rate 14 dBm Power...
Vega SI-12 / User Manual 3 OPERATION DEVICE APPEARANCE Vega SI-12 is represented in small plastic case which has four screws and mounting for DIN-rail. 1 – screw ø 2 mm х 2 – DIN-rail with mounting holes ø 3 mm 3 –...
Vega SI-12 / User Manual CONTACTS DESCRIPTION When connecting a radio modem to external devices, consider the internal circuitry of its pulse inputs shown below. CONTACT DESCRIPTION Ʇ Power - Power + IN1, IN2, IN3, IN4 Pulse inputs Ʇ Ʇ...
Page 11
Vega SI-12 / User Manual mechanical pushbutton; open-collector output. Equipment with NAMUR pulse output is not supported Polarity effects only "open collector" circuits. To reset all readings from the pulse inputs accumulated in the device memory you need to switch the device to the "Storage" mode by holding the start button pressed (min.
Vega SI-12 / User Manual LED INDICATIONS There is one red LED on the board. The indication is only used when the device is activating in the LoRaWAN® network and when the operating modes are changing. LED location on the...
5. Connecting all necessary wires to the SI-12 contacts. 6. Device launching – switching to the “Active” mode and registration in the network. Revision 13 of 4 August 2021...
Page 14
Vega SI-12 / User Manual Location of the launch button on the board 7. By the laptop you can make sure that the device successfully sends the data. 8. Before assembling the device, it is necessary to reset the pulses accumulated during testing and connection by switching the device to the "Storage"...
This part describes the SI-12 communication protocol with LoRaWAN network. ® In fields consisting of several bytes, the little endian byte order is used VEGA SI-12 PULSE COUNTER TRANSMITS THE FOLLOWING TYPES OF PACKETS 1. Packet with current readings Sent regularly on LoRaWAN port 2 Size in bytes...
Vega SI-12 / User Manual 4. Output state information packet Sent in case of change output state on LoRaWAN port 2 Size in bytes Field description Data type 1 byte Packet type, this packet == 5 uint8 1 byte Battery charge, %...
Vega SI-12 / User Manual VEGA SI-12 PULSE COUNTER RECEIVES PACKETS OF THE FOLLOWING TYPES 1. Real-time clock adjustment Sent by application on LoRaWAN port 4 Size in bytes Field description Data type 1 byte Packet type, this packet == 255...
Vega SI-12 / User Manual 5. Packet with settings Sent by application on LoRaWAN port 3, identical to such packet from device Size in bytes Field description Data type 1 byte Packet type, this packet == 0 uint8 2 bytes...
Page 20
Vega SI-12 / User Manual Table of ID of SI-12 parameters and these possible values ID of Description Data Possible values parameter length Confirmed uplinks 1 byte 1 – confirmed 2 – unconfirmed Uplinks number of transmissions 1 byte from 1 to 15...
Vega SI-12 / User Manual 5 STORAGE AND TRANSPORTATION REQUIREMENTS Vega SI-12 pulse counter shall be stored in the original packaging in heated room at temperatures +5 °С to +40 °С and relative humidity less than 85%. The counter shall be transported in covered freight compartments of all types at any distance at temperatures -40 °C to +85 °C.
Vega SI-12 / User Manual 7 WARRANTY The manufacturer guarantees that the product complies with the current technical documentation, subject to the storage, transportation and operation conditions specified in the "User Manual". The warranty period is 36 months if the number of data packets sent by the product is up to 25,000.
Page 24
Vega SI-12 / User Manual DOCUMENT INFORMATION Title Pulse Counter Vega SI-12 Document type Manual – Translation from Russian Document number V02-SI12-01 Revision and date 13 of 4 August 2021 Revision History Revision Date Name Comments 20.03.2017 Document creation date 14.04.2017...