AQUATROL ADP Series Instruction Manual

AQUATROL ADP Series Instruction Manual

Chemical dosing pump

Advertisement

ADP SERIES
CHEMICAL DOSING PUMP
MODELS: ADP-01141-1 & ADP-01141-2
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for AQUATROL ADP Series

  • Page 1 ADP SERIES CHEMICAL DOSING PUMP MODELS: ADP-01141-1 & ADP-01141-2 INSTRUCTION MANUAL...
  • Page 2: Table Of Contents

    1. Mechanical Faults 2. Electrical Faults VI. Maintenance 1. Pump Maintenance 2. Check Valve Maintenance 17-18 VII. Terms and Conditions Warranty ®Registered trademark / ™ Trademark. © 2016-2017 Aquatrol. All Rights Reserved AQUATROL P.O. Box 2235 Chino Hills, CA 91709 •...
  • Page 3: Initial Inspection

    Serial No: _____________________________ Installation Date: __________________ Installation Location: ___________________ When ordering replacement parts for your Aquatrol ChemDose Pump, please include complete Model Number and Serial Number of your unit. CAREFULLY READ AND UNDERSTAND ALL PRECAUTIONS BEFORE INSTALLING OR SERVICING ANY METERING AQUATROL P.O.
  • Page 4: Product Specifications

    Suction and the delivery valve: PVC, PP, SS316, PTFE • Filter: PP • Injection valve: PP (G1/2”) • Suction tube: PVC, PE, PTFE • Delivery tube: PVC, PE, PTFE • Seals: FPM AQUATROL P.O. Box 2235 Chino Hills, CA 91709 •...
  • Page 5: Pump Dimensions

    SIDE 4.05 in 103 mm 2.4 in 61 mm 0.3 in 8 mm 3.4 in 0.23 in 85.5 mm 6 mm 3.4 in 3.5 in 86 mm 88.5 mm BACK BASE AQUATROL P.O. Box 2235 Chino Hills, CA 91709 •...
  • Page 6: Pre-Installation Information

    WATER PRE-PRIME All Aquatrol ChemDose pumps are pre-primed with water when shipped from the factory. If your solution is not compatible with water, disassemble the Pump Head Assembly. Thoroughly dry the pump head, valves, seal rings, balls and Liquifram™...
  • Page 7 III. PRE-INSTALLATION INFORMATION TUBING CONNECTIONS ALWAYS use Aquatrol supplied tubing with your pump, as the tubing is specifically designed for use with the pump fittings. It is recommended that all tubing be shielded to prevent possible injury in case of rupture or accidental damage.
  • Page 8 » The pump MUST be connected to a good grounded ground. » All wiring must conform to local electrical codes. » DO NOT USE ADAPTERS! CORRECT INCORRECT AQUATROL P.O. Box 2235 Chino Hills, CA 91709 •...
  • Page 9: Transportation And Storage

    Improper liquids can damage the pump material can damage the pump or the operator. Aquatrol can help the user select the pump according to the characteristics of the liquid. Aquatrol will not be held responsible for damage deriving from improper use of the pump.
  • Page 10: Installation

    If the standard tube is not used, the thin tube should be used. This is good for the fi rst start of the pump. (Figure 2). FIGURE 2 AQUATROL P.O. Box 2235 Chino Hills, CA 91709 •...
  • Page 11 Install the back pressure valve on the delivery tube (Figure 3). » Install the exhaust valve or drill the exhaust hole on the highest dot of the tube to damage the siphon. FIGURE 3 AQUATROL P.O. Box 2235 Chino Hills, CA 91709 •...
  • Page 12: Connecting To Power

    IV. INSTALLATION CONNECTING TO POWER The ADP Series pump is supplied with 4.9 ft (1.5 meter) power cable and plug. However, when the pump is connected to a main circuit, an individual circuit breaker should be added between the pump and the main circuit and grounded to the pump tightly.
  • Page 13 One side is connected with the injection valve; the other side is connected with the delivery valve of the pump. • The size of the injection is ½” and can be installed on the pipe directly. AQUATROL P.O. Box 2235 Chino Hills, CA 91709 •...
  • Page 14: Programming

    PROGRAMMING THE ADP PUMP Power Light Indication Working Light Indication ON/OFF Key UP Key DOWN Key Power Cable LED Screen PUMP MUST BE INSTALLED ACCORDING TO THE PREVIOUS RECOMMENDATIONS IN THIS CHAPTER AQUATROL P.O. Box 2235 Chino Hills, CA 91709 •...
  • Page 15 STEP 4: The working frequency will be displayed on the LED Screen. STEP 5: Push the UP or DOWN buttons to adjust to your Frequency. AQUATROL P.O. Box 2235 Chino Hills, CA 91709 •...
  • Page 16: Troubleshooting

    Shut down the power, remove the pump and return it to the manufacturer or distributor. • The pump works only once: » Remove the pump and return it to the manufacturer or distributor. AQUATROL P.O. Box 2235 Chino Hills, CA 91709 •...
  • Page 17: Maintenance

    It is suggested that they periodically be checked and replaced if needed. The Aquatrol ChemDose pump has four (4) internal check valves which can be accessed by removing the nuts from the suction and delivery valve head.
  • Page 18 “cross pattern” facing up. (See diagram). • Once check valves are reinserted in the proper direction reconnect the pump for use. TOP side with a ”cross pattern” BOTTOM side with a “round pattern” AQUATROL P.O. Box 2235 Chino Hills, CA 91709 •...
  • Page 19: Terms And Conditions

    Warranty is prorated from date of sale. Improper use of the equipment invalidates the above guarantee. Warrantor: AQUATROL - PO BOX 2235 Chino Hills, CA 91709, USA WARRANTY. EXCEPT AS EXPRESSLY WARRANTED IN WRITING BY THE SELLER, THE GOODS SOLD BY THE SELLER ARE PURCHASED BY THE BUYER ”AS IS.” THE SELLER DOES NOT WARRANT THAT THE GOODS ARE OF MERCHANTABLE QUALITY OR THAT THEY CAN BE USED FOR ANY PARTICULAR PURPOSE.
  • Page 20 DISTRIBUTED BY: AQUATROL P.O. Box 2235 Chino Hills, CA 91709 • WWW.AQUATROLTECH.COM...