87. [Time to OFF] Scheduling (Command: f e)
Sets Off Timer settings.
Depending on the model, the number of schedules for Timer
Power Off can be either 16 or 21.
Transmission
(f)(e)( )(Set ID)( )(Data1)( )(Data2)( )(Data3)(Cr)
Data1
1. To f1h ~ ffh, a1h ~ a6h (data reading)
F1 ~ FF: Read data for the 1st to 15th times for Timer
Power On.
A1 ~ A6: Read data for the 16th to 21st times for Timer
Power On.
2. e1h ~ efh, b1h ~ b6h (Deletes one index), e0h (Deletes
all indexes)
E0: Delete all Timer Power Off's
E1 ~ EF: Delete the 1st to 15th times for Timer Power Off.
B1 ~ B6: Delete the 16th ~ 21st times for Timer Power
Off.
3. 01h to 0ch (Timer Power Off days setting)
02: Repeat Daily
03: Repeat from Monday to Friday
04: Repeat from Monday to Saturday
05: Repeat from Saturday to Sunday
06: Repeat on Sunday
07: Repeat on Monday
08: Repeat on Tuesday
09: Repeat on Wednesday
0A: Repeat on Thursday
0B: Repeat on Friday
0C: Repeat on Saturday
Data2 00-17: 00 - 23 hours
Data3 00-3B: 00 - 59 minutes
* To read or delete a Timer Power Off you have set, [Data2]
[Data3] must be set to FF.
Example 1: fe 01 f1 ff ff - Reads the 1st index data in Timer
Power Off.
Example 2: fe 01 e1 ff ff - Reads the 1st index data in Timer
Power Off.
Example 3: fe 01 04 02 03 - Sets the Timer Power Off as
Monday - Saturday 02:03.
* This feature only works when Clock 1 (year/month/day) and
Clock 2 (hour/minute/second) have been set.
Acknowledgment
(e)( )(Set ID)( )(OK/NG)(Data1)(Data2)(Data3)(x)
88. LCIN008 Control (Command: s n, b8)
It controls the LCIN008 device.
Transmission
(s)(n)( )(Set ID)( )(b)(8)( )(Data1)(Data2)(Cr)
Data 1 00: LCIN008 Power
01: LCIN008 Brightness
Data 2
1. For Power
0 x 00: Off
0 x 01: On
2. For Brightness
0 x ff: Read
0 x 00 ~ 0 x 64: Applies a set value
Acknowledgement
(n)( )(Set ID)( )(OK/NG)(b)(8)(Data1)(Data2)(x)
* This feature may not be available for all models.
* Other commands do not work for a certain time after
applying.
89. [Transfer Control] (Command: s n, cb)
It transfers the command to RS232C out.
Transmission
(s)(n)( )(Set ID)( )(c)(b)( )(Data)(Cr)
Data
Data that goes out to RS232C out
Acknowledgment
(n)( )(Set ID)( )(OK/NG)(c)(b)(Data)(x)
Data
Response value of Data transferred to RS232C
out
* This feature may not be available for all models.
* Other commands do not work for a certain time after
applying.
90. Multichannel (Command: s n, 76)
It changes the channel.
Transmission
(s)(n)( )(Set ID)( )(7)(6)( )(Data)(Cr)
Data
01 - 09: Channel to switch to
Acknowledgment
(n)( )(Set ID)( )(OK/NG)(7)(6)(Data)(x)
* This feature may not be available for all models.
111