Do you have a question about the KILL-BACT and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for CTR KILL-BACT
Page 1
Ultrasonic Nebulizer KILL-BACT COD. 4018150 CTR S.R.L. Via T. ed E. Manzini, 9 – 43126 Parma – Italy Tel: +39-0521.957611 – Fax: +39-0521.957677 Internet: http://www.ctrgroup.it; e-mail: info@ctrgroup.it OPERATING MANUAL Rev. 1 – 04/2011...
Page 2
IMPORTANT ! We recommend you thouroughly read the instructions provided in this manual before switching on the device. This will enable you to obtain excellent performance and reliability over time. Store this manual close to the device for quick reference by operators! The Manufacturer shall not be liable for failures or other consequences deriving from incorrect procedures on the part of the User.
Page 3
Dear Customer, Congratulations on purchasing our KILL-BACT COD. 4018150 ultrasonic nebulizer, a very modern instrument which will help you clean the interior of any vehicle. The technology applied and the quality achieved in years of experience in the sector, have made KILL-BACT COD.
INDEX Manufacturer’s CE Declaration of Conformity ................5 1 INTRODUCTION ........................6 2 SAFETY PRECAUTIONS ....................... 7 2.1 For the device ........................7 2.2 For the user.......................... 8 2.3 Correct Disposal of product (WEEE Directive)..............8 3 TECHNICAL CHARACTERISTICS..................9 3.1 General ..........................
Via T. ed E. Manzini, 43126 PARMA - ITALY Tel: +39-0521.957611 – Fax: +39-0521.957677 Declare under its sole responsibility that the product; Ultrasonic Nebulizer Model KILL-BACT - Code 4018150 Complies all the provisions of Machinery directive 2006/42/CE, plus the directives: · 2006/95/EC (LVD) ·...
The liquid particles completely sanitize the conditioning system (including ducts and fans), to stop the spreading of bacteria and germs and eliminate unpleasant smells inside the vehicle. For best results, we recommend you carry out a treatment with KILL-BACT COD. 4018150 at least twice a year.
SAFETY PRECAUTIONS For the device • Before each use, check the device, and the supply cable. Do not use the device if the cable is damaged. Any damage must be repaired by qualified personnel. • Store the device is a dry place, sheltered from the weather. •...
For the user • Carefully read though this operation manual before switching on power. • The instrument must be used only by qualified, trained personnel. • Use only the cable supplied with the instrument. • After the treatment ventilate the interior for approx. 5 – 10 minutes. Correct Disposal of product (WEEE Directive) ATTENTION The mark following indicates that it should not be disposed, with other household...
TECHNICAL CHARACTERISTICS General Power supply: 230 Vac 50/60 Hz Absorbed current: Approx. 0,15 Ampere Dimensions: L= 295 mm, H = 220 mm, P = 150 mm Weight: ~3,1 Kg nebulized liquid: Circa 15 ml/min Noise level: < 70 dBA Operating temperature: 0°...
PREPARATION FOR USE Content of package The KILL-BACT COD. 4018150 ultrasonic nebulizer comes in a can which contains the following material: 1. Ultrasonic nebulizer 2. Operating Manual 3. Conveyor Tube 4. Supply cable IMPORTANT Ensure that all the parts listed are contained in the case, if any parts are missing or damaged contained your local dealer.
Leds description • HIGH LEVEL: (GREEN led) is on when, during the filling of the tank, exceeds the maximum permitted level of liquid. The device is stopped and to operate the unit you must restore the level of liquid. • READY/ON: (GREEN led) begins to flash as soon as you start to pour the liquid inside the tank.
Preparing the device • Insert the power connection into the input in the front part of the device (Picture A), and insert the power plug into the power socket. • Fill the tank of NEBULA 2011CTR with a bottle full of liquid (Picture B); The green led READY /ON starts to flash.
ATTENTION If the temperature inside the vehicle exceeds 60 ° C , switch on the air conditioning to bring the temperature below 60 ° C before using t he device. NOTE Before use, check the pollen filter/active carbon filter and if too dirty replace them. •...
Page 14
• Switch off the air conditioning system, using the special control. If the vehicle has an automatic conditioning system, set it to ECONOMY mode • Set the temperature to the minimum. • Select internal air recirculation mode • Set the air fan to the minimum. •...
Page 15
• Press the ON/OFF button of the device for the start the treatment phase (Picture H). • Check whether the nebulized liquid is being sucked into the recirculation air intake (Picture I). • Leave the vehicle and close the doors. ATTENTION Do not remain inside the vehicle during the treatment and do not breath in the nebulized liquid.
MAINTENANCE • Disconnect supply cable from the device and pull out the Conveyor Tube . • Pour the residual liquid into a container (approx 30 ml) (Picture L ). The liquid remaining can be used for the next application. • To clean regularly, simply pour in some tap water through the opening where the container is attached.
Need help?
Do you have a question about the KILL-BACT and is the answer not in the manual?
Questions and answers