Quick Links

Masoneilan
8000 Models
Electro-pneumatic
Positioners and Transducers
ATEX Instruction Manual (Rev. A)
Baker Hughes Data Classification : Public

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Masoneilan 8000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Baker Hughes Masoneilan 8000

  • Page 1 Masoneilan ™ 8000 Models Electro-pneumatic Positioners and Transducers ATEX Instruction Manual (Rev. A) Baker Hughes Data Classification : Public...
  • Page 2: Table Of Contents

    11. Special Conditions of Work ........................18 12. Special Conditions of Use ......................... 18 12.1. Common for Intrinsic Safety and Flameproof .....................18 12.2. Intrinsically Safe Apparatus ..........................19 12.3. Flameproof Apparatus: ............................20 13. Complementary Documentation ....................... 20 © 2021 Baker Hughes Company. All rights reserved. Baker Hughes...
  • Page 3 REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR’S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, BAKER HUGHES COMPANY (AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE TYPE OF EQUIPMENT PROVIDED.
  • Page 4: Warning

    Safe Site Work Practices Baker Hughes reserves the right to discontinue manufacture of any product or change product materials, design, or specifications without notice.
  • Page 5: Instrument Operation

    7 European model - without integrated relay 8 European model - with integrated relay 055 Weather-proof 057 Flameproof and Weather-proof (ATEX/IECEx) 058 Intrinsically safe and Weather-proof (ATEX/IECEx) © 2021 Baker Hughes Company. All rights reserved. Masoneilan 8000 Models Positioners and Transducers ATEX Manual...
  • Page 6 5 36000 Control Ball Valves, multi-lobe cam 6 HPBV, multi-lobe cam 7 Varipak™, basic cam 8 Varimax™, multi-lobe cam Weather-proof Flameproof and Weather-proof (ATEX/IECEx) Intrinsically safe and Weather-proof (ATEX/IECEx) 8013 © 2021 Baker Hughes Company. All rights reserved. Baker Hughes...
  • Page 7: Technical Specifications

    † Low temperature instrument : -55°C to +60°C • Storage and transportation temperature : -55°C to +90°C • Maximum air supply pressure : 5.20 bar (75 psi) © 2021 Baker Hughes Company. All rights reserved. Masoneilan 8000 Models Positioners and Transducers ATEX Manual...
  • Page 8: Schematic

    Ex ia IIC T6 Ga Ta -55°C to +40°C Ex ia IIIC T85°C Da 1. The temperature can be limited to -20°C, depending of gasket material inside the pneumatic block. © 2021 Baker Hughes Company. All rights reserved. Baker Hughes...
  • Page 9: Electrical Safety Parameters

    , + 80° C Ex tb IIIC T100°C Db IP65 1. The temperature can be limited to -20°C depending of gasket material inside the pneumatic block. © 2021 Baker Hughes Company. All rights reserved. Masoneilan 8000 Models Positioners and Transducers ATEX Manual...
  • Page 10: Electrical Safety Parameter

    † Input signal : 4-20mA Electrical Characteristics 6.1. Intrinsically safe apparatus • Signal : 4-20 mA, • Input impedance : 216 Ohm, • Coil : blue colour code, with 2 diodes. 10 | © 2021 Baker Hughes Company. All rights reserved. Baker Hughes...
  • Page 11: Flameproof Apparatus

    - Output (O) to the actuator for the 8008 or 8013 or to the positioner for the 8007. † Minimum tubing diameter: 4 x 6 mm. Remark: Tubing size must be in accordance with the actuator dimension. © 2021 Baker Hughes Company. All rights reserved. | 11 Masoneilan 8000 Models Positioners and Transducers ATEX Manual...
  • Page 12: Electrical Connection, Installation And Start-Up

    † In case an adaptor or reducer must be added, it must be apparatus certified ATEX (type Cooper CAPRI CODEC). † The cable entry with or without its adaptor/reducer must be installed in conformance with the figure below: Cable Gland Accessories Mounting on Instruments 12 | © 2021 Baker Hughes Company. All rights reserved. Baker Hughes...
  • Page 13: Electrical Connection

    Reverse action: an increase of the signal results in a decrease of the output pressure. Below picture gives the coil wires connection to the printed circuit board. (*) Cross wires above the beam. © 2021 Baker Hughes Company. All rights reserved. | 13 Masoneilan 8000 Models Positioners and Transducers ATEX Manual...
  • Page 14: Installation And Start-Up

    For both installations, the measurement device representation is only for location information and not for physical connections. 14 | © 2021 Baker Hughes Company. All rights reserved. Baker Hughes...
  • Page 15: Start-Up

    In any case, check that the installed nozzle (Ref 16) is suitable for the valve size, for the actuator and for the instrument air supply pressure. © 2021 Baker Hughes Company. All rights reserved. | 15 Masoneilan 8000 Models Positioners and Transducers ATEX Manual...
  • Page 16: 8007 Or 8008 Transducer Calibration

    • Adjust the balance spring (6) as to the valve fully strokes for the full input signal range • Repeat the 2 above steps until the adjustment is correct • Tighten locknuts (7) and (11) • Strictly follow safety instructions under §8.4 before start-up 16 | © 2021 Baker Hughes Company. All rights reserved. Baker Hughes...
  • Page 17: Maintenance

    † Unscrew the nozzle (16) from the case (14) † Clean the nozzle with solvent and blow out hole with clean air † Reassemble all the parts. © 2021 Baker Hughes Company. All rights reserved. | 17 Masoneilan 8000 Models Positioners and Transducers ATEX Manual...
  • Page 18: Special Conditions Of Work

    The label below is shown for example only and is not representative to the 8000 Series positioner label. 18 | © 2021 Baker Hughes Company. All rights reserved. Baker Hughes...
  • Page 19: Intrinsically Safe Apparatus

    The entity parameters of the voltage supply must be compatible with the entity parameters of the 8000 Series described §4.2. © 2021 Baker Hughes Company. All rights reserved. | 19 Masoneilan 8000 Models Positioners and Transducers ATEX Manual...
  • Page 20: Flameproof Apparatus

    Each apparatus is shipped with an ATEX Instruction Manual. This document is as a minimum a copy of this document. It is available in all official languages of the European Union Countries. 20 | © 2021 Baker Hughes Company. All rights reserved. Baker Hughes...
  • Page 21 NOTES: © 2021 Baker Hughes Company. All rights reserved. | 21 Masoneilan 8000 Models Positioners and Transducers ATEX Manual...
  • Page 22 NOTES: 22 | © 2021 Baker Hughes Company. All rights reserved. Baker Hughes...
  • Page 23 NOTES: © 2021 Baker Hughes Company. All rights reserved. | 23 Masoneilan 8000 Models Positioners and Transducers ATEX Manual...
  • Page 24 Copyright 2021 Baker Hughes Company. All rights reserved. Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not make any representation as to the accuracy or completeness of the information and makes no warranties of any kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness for a particular purpose or use.

This manual is also suitable for:

Masoneilan 8013Masoneilan 8007Masoneilan 8008

Table of Contents