Advertisement

Quick Links

Adding to Remove from Z-Wave T M Network ........................................................................................................ 1
Z- Wave TM Notification ...................................................................................................................................... 2
Z-Wave TM Message Report ................................................................................................................................. 2
* Motion Report: ......................................................................................................................................... 3
* Tamper Report: ......................................................................................................................................... 3
* Timing Report: ......................................................................................................................................... 3
Power Up Procedure ............................................................................................................................................ 3
* Battery Power Check ................................................................................................................................. 3
* PIR Warm Up ........................................................................................................................................... 3
* NWI ........................................................................................................................................................ 4
* Wake ....................................................................................................................................................... 4
Security Network ................................................................................................................................................ 4
Operation Mode .................................................................................................................................................. 4
Choosing a Suitable Location ................................................................................................................................ 4
Z-Wave Configuration Settings ............................................................................................................................. 5
Z-Wave Supported Command Class ....................................................................................................................... 5
Specifications ..................................................................................................................................................... 8
FCC Interference Statement .................................................................................................................................. 9
Warning ............................................................................................................................................................. 9
Table of Content

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SI-102 and is the answer not in the manual?

Questions and answers

Summary of Contents for AirLive SI-102

  • Page 1: Table Of Contents

    Table of Content Adding to Remove from Z-Wave T M Network ......................1 Z- Wave TM Notification ............................2 Z-Wave TM Message Report ..........................2 * Motion Report: ............................3 * Tamper Report: ............................3 * Timing Report: ............................3 Power Up Procedure ............................
  • Page 2: Adding To Remove From Z-Wave T M Network

    SI-102 SI-102-FCC Motion Sensor The motion sensor SI-102 has PIR function, based on Z-Wave technology. This device is a Security Enabled Z-Wave Plus Product. Z-Wave is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments.
  • Page 3: Z- Wave Tm Notification

    Function Description 1. Have Z-Wave Controller entered inclusion mode. 2. Pressing button once to enter the inclusion mode. 3. After add successful, the device will wake to receive the setting command from Z-Wave controller about 20 seconds. Remove 1. Have Z-Wave Controller entered exclusion mode.
  • Page 4: Motion Report

    * Motion Report: When the PIR motion detected, the device will unsolicited to send the report to the nodes in the group 1. Notification Report (V4) Notification Type: Home Security (0x07) Event: Motion Detection, Unknown Location (0x08) Sensor Binary Report (V2) Sensor Type: Motion (0x0C) Sensor Value: 0xFF * Tamper Report:...
  • Page 5: Nwi

    * NWI When the device power on, the device will check is it already adding to the network? If doesn't, it will auto start the NWI mode. The LED will flash in every second and continue 30 seconds. Until timeout or the device successful to inclusion by controller.
  • Page 6: Z-Wave Configuration Settings

    Z-Wave Configuration Settings Notice: All of the configuration, the data size is 1. The configuration mark with star(*), means after the remove the setting still keep, don't reset to factory default. Unless the user execute the “RESET” procedure. The reserve bit or not supported bit is allowed any value, but no effect. Z-Wave Supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2...
  • Page 7 Bit3: When Bit2 is 0 (Enable), Are the device and the lighting in the same room? 0: In the same room (Default), 1: In the different room. Bit4: Disable delay 5 seconds to turn off the light, when door/window closed. (1:Disable, 0:Enable) Bit5: Disable auto turn off the light, after door/window opened to turn on the light.
  • Page 8 Turn Off 0~127 After turn on the lighting, setting the delay time to turn off the Light Time lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command. Auto Report 0~127 The interval time for auto report the battery level.
  • Page 9: Specifications

    RF Maximum Power: +5dBm Operating Temperature: -10oC ~ 40oC For indoor use only. Specifications subject to change without notice due to continuing product improvement. OvisLink Corp., http://www.airlive.com/ TEL: +886 2 2218 6888 FAX: +886 2 2918 6988 FCC ID: ODMSI102...
  • Page 10: Fcc Interference Statement

    FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

Table of Contents